메뉴 건너뛰기




Volumn 21, Issue 7, 2009, Pages

Optimizing analysis of stable isotope breath tests to estimate gastric emptying of solids

Author keywords

Scintigraphy; Spirulina

Indexed keywords

CARBON 13; STABLE ISOTOPE; TECHNETIUM SULFUR COLLOID TC 99M;

EID: 67650472451     PISSN: 13501925     EISSN: 13652982     Source Type: Journal    
DOI: 10.1111/j.1365-2982.2009.01283.x     Document Type: Article
Times cited : (45)

References (15)
  • 1
    • 40949119036 scopus 로고    scopus 로고
    • Consensus recommendations for gastric emptying scintigraphy. A Joint Report of the Society of Nuclear Medicine and the American Neurogastroenterology and Motility Society
    • Abell TL, Camilleri M, Donohoe K et al. Consensus recommendations for gastric emptying scintigraphy. A Joint Report of the Society of Nuclear Medicine and the American Neurogastroenterology and Motility Society. Am J Gastroenterol 2008 103 : 753 63.
    • (2008) Am J Gastroenterol , vol.103 , pp. 753-63
    • Abell, T.L.1    Camilleri, M.2    Donohoe, K.3
  • 2
    • 0027164833 scopus 로고
    • Measurement of gastric emptying rate of solids by means of a carbon-labeled octanoic acid breath test
    • Ghoos YF, Maes BD, Geypens BJ et al. Measurement of gastric emptying rate of solids by means of a carbon-labeled octanoic acid breath test. Gastroenterology 1994 104 : 1640 7.
    • (1994) Gastroenterology , vol.104 , pp. 1640-7
    • Ghoos, Y.F.1    Maes, B.D.2    Geypens, B.J.3
  • 3
    • 0030612036 scopus 로고    scopus 로고
    • 13C-octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility and comparison with scintigraphy
    • Choi M-G, Camilleri M, Burton DD, Zinsmeister AR, Forstrom LA, Nair KS. 13C-octanoic acid breath test for gastric emptying of solids: accuracy, reproducibility and comparison with scintigraphy. Gastroenterology 1997 112 : 1155 62.
    • (1997) Gastroenterology , vol.112 , pp. 1155-62
    • Choi, M.-G.1    Camilleri, M.2    Burton, D.D.3    Zinsmeister, A.R.4    Forstrom, L.A.5    Nair, K.S.6
  • 4
    • 0034106322 scopus 로고    scopus 로고
    • A valid, accurate, office based non-radioactive test for gastric emptying of solids
    • Lee JS, Camilleri M, Zinsmeister AR, Burton DD, Kost LJ, Klein PD. A valid, accurate, office based non-radioactive test for gastric emptying of solids. Gut 2000 46 : 768 73.
    • (2000) Gut , vol.46 , pp. 768-73
    • Lee, J.S.1    Camilleri, M.2    Zinsmeister, A.R.3    Burton, D.D.4    Kost, L.J.5    Klein, P.D.6
  • 5
    • 0033791788 scopus 로고    scopus 로고
    • Toward office-based measurement of gastric emptying in symptomatic diabetics using [13C]octanoic acid breath test
    • Lee J-S, Camilleri M, Zinsmeister AR et al. Toward office-based measurement of gastric emptying in symptomatic diabetics using [13C]octanoic acid breath test. Am J Gastroenterol 2000 95 : 2751 61.
    • (2000) Am J Gastroenterol , vol.95 , pp. 2751-61
    • Lee, J.-S.1    Camilleri, M.2    Zinsmeister, A.R.3
  • 6
    • 0035686231 scopus 로고    scopus 로고
    • Validation of a stable isotope gastric emptying test for normal, accelerated or delayed gastric emptying
    • Viramontes BE, Kim D-Y, Camilleri M et al. Validation of a stable isotope gastric emptying test for normal, accelerated or delayed gastric emptying. Neurogastroenterol Motil 2001 13 : 567 74.
    • (2001) Neurogastroenterol Motil , vol.13 , pp. 567-74
    • Viramontes, B.E.1    Kim, D.-Y.2    Camilleri, M.3
  • 7
    • 44749093426 scopus 로고    scopus 로고
    • A stable isotope breath test with a standard meal for abnormal gastric emptying of solids in the clinic and in research
    • Szarka LA, Camilleri M, Vella A et al. A stable isotope breath test with a standard meal for abnormal gastric emptying of solids in the clinic and in research. Clin Gastroenterol Hepatol 2008 6 : 635 43.
    • (2008) Clin Gastroenterol Hepatol , vol.6 , pp. 635-43
    • Szarka, L.A.1    Camilleri, M.2    Vella, A.3
  • 8
    • 0020332610 scopus 로고
    • 2 measurements
    • 2 measurements. Fed Proc 1982 41 : 2698 701.
    • (1982) Fed Proc , vol.41 , pp. 2698-701
    • Klein, P.D.1
  • 11
    • 0004282518 scopus 로고
    • SAS Institute Inc. Version 6, 4th edn. Vol. 2. Cary, NC. SAS Institute
    • SAS Institute Inc. SAS/STAT Users Guide, Version 6, 4th edn, Vol. 2. Cary, NC : SAS Institute, 1989, 1135 94.
    • (1989) SAS/STAT Users Guide , pp. 1135-94
  • 12
    • 0021776312 scopus 로고
    • Predicting basal metabolic rate, new standards and review of previous work
    • Schofield WN. Predicting basal metabolic rate, new standards and review of previous work. Hum Nutr Clin Nutr 1985 39 : 541.
    • (1985) Hum Nutr Clin Nutr , vol.39 , pp. 541
    • Schofield, W.N.1
  • 13
    • 33845518848 scopus 로고    scopus 로고
    • Comparison between gastric scintigraphy and the [13C]-acetate breath test with Wagner-Nelson analysis in humans
    • Sanaka M, Urita Y, Sugimoto M, Yamamoto T, Kuyama Y. Comparison between gastric scintigraphy and the [13C]-acetate breath test with Wagner-Nelson analysis in humans. Clin Exp Pharmacol Physiol 2006 33 : 1239 43.
    • (2006) Clin Exp Pharmacol Physiol , vol.33 , pp. 1239-43
    • Sanaka, M.1    Urita, Y.2    Sugimoto, M.3    Yamamoto, T.4    Kuyama, Y.5
  • 14
    • 0347994087 scopus 로고    scopus 로고
    • Estimating the generalized concordance correlation coefficient through variance components
    • Carrasco JL, Jover L. Estimating the generalized concordance correlation coefficient through variance components. Biometrics 2003 59 : 849 58.
    • (2003) Biometrics , vol.59 , pp. 849-58
    • Carrasco, J.L.1    Jover, L.2
  • 15
    • 0035040933 scopus 로고    scopus 로고
    • Gastric emptying characteristics of a novel (13)C-octanoate-labeled muffin meal
    • Chey WD, Shapiro B, Zawadski A, Goodman K. Gastric emptying characteristics of a novel (13)C-octanoate-labeled muffin meal. J Clin Gastroenterol 2001 32 : 394 9.
    • (2001) J Clin Gastroenterol , vol.32 , pp. 394-9
    • Chey, W.D.1    Shapiro, B.2    Zawadski, A.3    Goodman, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.