-
3
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
-
Sodickson D.K., and Manning W.J. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 38 (1997) 591-603
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
4
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold M.A., Jakob P.M., Heidemann R.M., Nittka M., Jellus V., Wang J., et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47 6 (2002) 1202-1210
-
(2002)
Magn Reson Med
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
-
5
-
-
0033854213
-
Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
-
Kyriakos W.E., Panych L.P., Kacher D.F., Westin C.F., Bao S.M., Mulkern R.V., et al. Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med 44 2 (2000) 301-308
-
(2000)
Magn Reson Med
, vol.44
, Issue.2
, pp. 301-308
-
-
Kyriakos, W.E.1
Panych, L.P.2
Kacher, D.F.3
Westin, C.F.4
Bao, S.M.5
Mulkern, R.V.6
-
6
-
-
33746892586
-
Accelerated volumetric MRI with a SENSE/GRAPPA combination
-
Blaimer M., Breuer F.A., Seiberlich N., Mueller M.F., Heidemann R.M., Jellus V., et al. Accelerated volumetric MRI with a SENSE/GRAPPA combination. J Magn Reson Med 24 (2006) 444-450
-
(2006)
J Magn Reson Med
, vol.24
, pp. 444-450
-
-
Blaimer, M.1
Breuer, F.A.2
Seiberlich, N.3
Mueller, M.F.4
Heidemann, R.M.5
Jellus, V.6
-
7
-
-
5044228870
-
SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method
-
Blaimer M., Breuer F.A., Mueller M.F., Heidemann R.M., Griswold M.A., and Jakob P.M. SMASH, SENSE, PILS, GRAPPA: how to choose the optimal method. Top Magn Reson Imaging 15 (2004) 223-236
-
(2004)
Top Magn Reson Imaging
, vol.15
, pp. 223-236
-
-
Blaimer, M.1
Breuer, F.A.2
Mueller, M.F.3
Heidemann, R.M.4
Griswold, M.A.5
Jakob, P.M.6
-
8
-
-
33644812347
-
Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)
-
Breuer F.A., Blaimer M., Mueller M.F., Seiberlich N., Heidemann R.M., Griswold M.A., et al. Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA). Magn Reson Med 55 (2006) 456-459
-
(2006)
Magn Reson Med
, vol.55
, pp. 456-459
-
-
Breuer, F.A.1
Blaimer, M.2
Mueller, M.F.3
Seiberlich, N.4
Heidemann, R.M.5
Griswold, M.A.6
-
9
-
-
0029310397
-
Optimal scan design for time varying tomographic imaging II: efficient design and experimental validation
-
Willis N.P., and Bresler Y. Optimal scan design for time varying tomographic imaging II: efficient design and experimental validation. IEEE Trans Image Process 4 (1995) 654-666
-
(1995)
IEEE Trans Image Process
, vol.4
, pp. 654-666
-
-
Willis, N.P.1
Bresler, Y.2
-
10
-
-
0011524968
-
Recovery of limited-extent images aliased because of spectral undersampling
-
Bones P.J., Alwesh N., Connolly T.J., and Blakeley N.D. Recovery of limited-extent images aliased because of spectral undersampling. JOSA A 18 (2001) 2079-2088
-
(2001)
JOSA A
, vol.18
, pp. 2079-2088
-
-
Bones, P.J.1
Alwesh, N.2
Connolly, T.J.3
Blakeley, N.D.4
-
11
-
-
0043066636
-
Efficient frequency-domain sample selection for recovering limited-support images
-
Blakeley N.D., Bones P.J., Millane R.P., and Renaud P. Efficient frequency-domain sample selection for recovering limited-support images. JOSA A 20 (2003) 67-77
-
(2003)
JOSA A
, vol.20
, pp. 67-77
-
-
Blakeley, N.D.1
Bones, P.J.2
Millane, R.P.3
Renaud, P.4
-
12
-
-
33750932786
-
Region-of-interest MRI: k-space sampling conditions
-
Aggarwal N., and Bresler Y. Region-of-interest MRI: k-space sampling conditions. ISBI (2006) 41-44
-
(2006)
ISBI
, pp. 41-44
-
-
Aggarwal, N.1
Bresler, Y.2
-
13
-
-
0242385483
-
k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations
-
Tsao J., Boesiger P., and Pruessmann K.P. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 50 (2003) 1031-1042
-
(2003)
Magn Reson Med
, vol.50
, pp. 1031-1042
-
-
Tsao, J.1
Boesiger, P.2
Pruessmann, K.P.3
-
14
-
-
0344703742
-
Optimal sampling in parallel magnetic resonance imaging
-
Aggarwal N., and Bresler Y. Optimal sampling in parallel magnetic resonance imaging. IEEE ICIP 2 (2003) 839-842
-
(2003)
IEEE ICIP
, vol.2
, pp. 839-842
-
-
Aggarwal, N.1
Bresler, Y.2
-
15
-
-
17144431972
-
Accelerated parallel magnetic resonance imaging by adaptive k-space sampling
-
Aggarwal N., and Bresler Y. Accelerated parallel magnetic resonance imaging by adaptive k-space sampling. IEEE ISBI (2004) 892-895
-
(2004)
IEEE ISBI
, pp. 892-895
-
-
Aggarwal, N.1
Bresler, Y.2
-
16
-
-
0034351116
-
Optimal k-space sampling in MRSI for images with a limited region of support
-
Gao Y., and Reeves S.J. Optimal k-space sampling in MRSI for images with a limited region of support. IEEE Trans Med Imaging 12 (2000) 1168-1178
-
(2000)
IEEE Trans Med Imaging
, vol.12
, pp. 1168-1178
-
-
Gao, Y.1
Reeves, S.J.2
-
17
-
-
0032738161
-
Sequential algorithms for observation selection
-
Reeves S.J., and Zhao Z. Sequential algorithms for observation selection. IEEE Trans Signal Processing 47 (1999) 123-132
-
(1999)
IEEE Trans Signal Processing
, vol.47
, pp. 123-132
-
-
Reeves, S.J.1
Zhao, Z.2
-
18
-
-
0000905616
-
Adjustment of an inverse matrix corresponding to changes in the elements of a given column or a given row of the original matrix
-
Sherman J., and Winifred J.M. Adjustment of an inverse matrix corresponding to changes in the elements of a given column or a given row of the original matrix. Ann Math Stat 20 (1949) 621
-
(1949)
Ann Math Stat
, vol.20
, pp. 621
-
-
Sherman, J.1
Winifred, J.M.2
-
19
-
-
0029265843
-
Surface coil MR imaging of the human brain with an analytic reception profile correction
-
Moyher S.E., Vigneron D.B., and Nelson S.J. Surface coil MR imaging of the human brain with an analytic reception profile correction. J Magn Reson Imaging 5 (1995) 139-144
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 139-144
-
-
Moyher, S.E.1
Vigneron, D.B.2
Nelson, S.J.3
-
21
-
-
10144256538
-
Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction
-
Wang Y., Johnston D.L., Breen J.F., Huston J., Jack C.R., Julsrud P.R., et al. Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction. Magn Reson Med 36 (1996) 551-556
-
(1996)
Magn Reson Med
, vol.36
, pp. 551-556
-
-
Wang, Y.1
Johnston, D.L.2
Breen, J.F.3
Huston, J.4
Jack, C.R.5
Julsrud, P.R.6
-
22
-
-
43149103214
-
Ordered k-space data acquisition in contrast enhanced magnetic resonance angiography (CE-MRA)
-
Wu B., Maclaren J., Bones P., Millane R., and Watts R. Ordered k-space data acquisition in contrast enhanced magnetic resonance angiography (CE-MRA). SPIE Medical Imaging, San Diego 6913 (2008) 691346
-
(2008)
SPIE Medical Imaging, San Diego
, vol.6913
, pp. 691346
-
-
Wu, B.1
Maclaren, J.2
Bones, P.3
Millane, R.4
Watts, R.5
-
23
-
-
11144348188
-
SENSE reconstruction with inaccurate sensitivity functions: effects and remedies
-
Xu D., Ying L., and Liang Z.P. SENSE reconstruction with inaccurate sensitivity functions: effects and remedies. IEEE EMBC 2 (2004) 1112-1115
-
(2004)
IEEE EMBC
, vol.2
, pp. 1112-1115
-
-
Xu, D.1
Ying, L.2
Liang, Z.P.3
-
24
-
-
33744540030
-
The use of an adaptive reconstruction for array coil sensitivity mapping and intensity normalization
-
Griswold M.A., Walsh D.O., Heidemann R.M., Haase A., and Jakob P.M. The use of an adaptive reconstruction for array coil sensitivity mapping and intensity normalization. Proc. ISMRM, Honolulu (2002) 2410
-
(2002)
Proc. ISMRM, Honolulu
, pp. 2410
-
-
Griswold, M.A.1
Walsh, D.O.2
Heidemann, R.M.3
Haase, A.4
Jakob, P.M.5
-
25
-
-
0038793945
-
Reconstruction of sensitivity encoded images using regularization and discrete time wavelet transform estimates of the coil maps
-
Lin F.-H., Kwong K., Chen Y., Belliveau J., and Wald L. Reconstruction of sensitivity encoded images using regularization and discrete time wavelet transform estimates of the coil maps. Proc. ISMRM, Glasgow, Scotland (2001) 2389
-
(2001)
Proc. ISMRM, Glasgow, Scotland
, pp. 2389
-
-
Lin, F.-H.1
Kwong, K.2
Chen, Y.3
Belliveau, J.4
Wald, L.5
-
26
-
-
68349151603
-
SENSE with partial Fourier homodyne reconstruction
-
King K.F., and Angelos L. SENSE with partial Fourier homodyne reconstruction. Proc. ISMRM, Denver, USA (2000) 323
-
(2000)
Proc. ISMRM, Denver, USA
, pp. 323
-
-
King, K.F.1
Angelos, L.2
-
27
-
-
30344484862
-
Combination of 2D sensitivity encoding and 2D partial Fourier techniques for improved acceleration in 3D contrast-enhanced MR angiography
-
Hu H.H., Madhuranthakam A.J., Kruger D.G., Glockner J.F., and Riederer S.J. Combination of 2D sensitivity encoding and 2D partial Fourier techniques for improved acceleration in 3D contrast-enhanced MR angiography. Magn Reson Med 55 1 (2006) 16-22
-
(2006)
Magn Reson Med
, vol.55
, Issue.1
, pp. 16-22
-
-
Hu, H.H.1
Madhuranthakam, A.J.2
Kruger, D.G.3
Glockner, J.F.4
Riederer, S.J.5
-
28
-
-
33846930381
-
Parallel MR imaging with accelerations beyond the number of receiver channels using real image reconstruction
-
Ji X.J., and Wright S.M. Parallel MR imaging with accelerations beyond the number of receiver channels using real image reconstruction. IEEE EMBS (2005) 735-738
-
(2005)
IEEE EMBS
, pp. 735-738
-
-
Ji, X.J.1
Wright, S.M.2
-
29
-
-
19544382334
-
Partial fourier partially parallel imaging
-
Bydder M., and Robson M.D. Partial fourier partially parallel imaging. Magn Reson Med 53 (2005) 1393-1401
-
(2005)
Magn Reson Med
, vol.53
, pp. 1393-1401
-
-
Bydder, M.1
Robson, M.D.2
-
30
-
-
1542346911
-
Parallel imaging reconstruction using automatic regularization
-
Lin F.H., Kwong K.K., Belliveau J.W., and Wald L.L. Parallel imaging reconstruction using automatic regularization. Magn Reson Med 51 (2004) 559-567
-
(2004)
Magn Reson Med
, vol.51
, pp. 559-567
-
-
Lin, F.H.1
Kwong, K.K.2
Belliveau, J.W.3
Wald, L.L.4
-
31
-
-
35048823743
-
Parallel MRI reconstruction using variance partitioning regularization
-
Lin F.H., Wang F.N., Ahlfors S.P., Hamalainen M.S., and Belliveau J.W. Parallel MRI reconstruction using variance partitioning regularization. Magn Reson Med 58 (2005) 735-744
-
(2005)
Magn Reson Med
, vol.58
, pp. 735-744
-
-
Lin, F.H.1
Wang, F.N.2
Ahlfors, S.P.3
Hamalainen, M.S.4
Belliveau, J.W.5
-
32
-
-
10044289695
-
POCSENSE: POCS-based reconstruction for sensitivity encoded magnetic resonance imaging
-
Samsonov A.A., Kholmovski E.G., Parker D.L., and Johnson C.R. POCSENSE: POCS-based reconstruction for sensitivity encoded magnetic resonance imaging. Magn Reson Med 52 (2004) 1397-1406
-
(2004)
Magn Reson Med
, vol.52
, pp. 1397-1406
-
-
Samsonov, A.A.1
Kholmovski, E.G.2
Parker, D.L.3
Johnson, C.R.4
-
33
-
-
0034794323
-
Advances in sensitivity encoding with arbitrary k-space trajectories
-
Pruessmann K.P., Weiger M., Bornert P., and Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 46 (2001) 638-651
-
(2001)
Magn Reson Med
, vol.46
, pp. 638-651
-
-
Pruessmann, K.P.1
Weiger, M.2
Bornert, P.3
Boesiger, P.4
-
34
-
-
35948946154
-
SENSE phase-constrained magnitude reconstruction with iterative phase refinement
-
Lew C., Pineda A.R., Clayton D., Spielman D., Chan F., and Bammer R. SENSE phase-constrained magnitude reconstruction with iterative phase refinement. Magn Reson Med 58 (2007) 910-921
-
(2007)
Magn Reson Med
, vol.58
, pp. 910-921
-
-
Lew, C.1
Pineda, A.R.2
Clayton, D.3
Spielman, D.4
Chan, F.5
Bammer, R.6
-
35
-
-
36349017272
-
Parallel image reconstruction using B-spline approximation (PROBER)
-
Petr J., Kybic J., Bock M., Muller S., and Hlavac V. Parallel image reconstruction using B-spline approximation (PROBER). Magn Reson Med 58 (2007) 582-591
-
(2007)
Magn Reson Med
, vol.58
, pp. 582-591
-
-
Petr, J.1
Kybic, J.2
Bock, M.3
Muller, S.4
Hlavac, V.5
-
36
-
-
36849088522
-
Sparse MRI: The application of compressed sensing for rapid MR imaging
-
Lustig M., Donoho D., and Pauly J.M. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 58 (2007) 1182-1195
-
(2007)
Magn Reson Med
, vol.58
, pp. 1182-1195
-
-
Lustig, M.1
Donoho, D.2
Pauly, J.M.3
-
37
-
-
68349147210
-
Applying compressed sensing (CS) to parallel MRI
-
Wu B., Bones P.J., Watts R., and Millane R.P. Applying compressed sensing (CS) to parallel MRI. Proc. ISMRM, Toronto, Canada (2008) 1480
-
(2008)
Proc. ISMRM, Toronto, Canada
, pp. 1480
-
-
Wu, B.1
Bones, P.J.2
Watts, R.3
Millane, R.P.4
-
38
-
-
26844558803
-
Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories
-
Qu P., Zhong K., Zhang B., Wang J., and Shen G.X. Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories. Magn Reson Med 54 (2005) 1040-1045
-
(2005)
Magn Reson Med
, vol.54
, pp. 1040-1045
-
-
Qu, P.1
Zhong, K.2
Zhang, B.3
Wang, J.4
Shen, G.X.5
|