-
1
-
-
38249035106
-
An algorithm for NMR imaging reconstruction based on multiple RF receiver coils
-
Carlson JW. An algorithm for NMR imaging reconstruction based on multiple RF receiver coils. J Magn Reson 1987;74:376-380.
-
(1987)
J Magn Reson
, vol.74
, pp. 376-380
-
-
Carlson, J.W.1
-
2
-
-
0023870882
-
Fast MRI data acquisition using multiple detectors
-
Hutchinson M, Raff U. Fast MRI data acquisition using multiple detectors. Magn Reson Med 1988;6:87-91.
-
(1988)
Magn Reson Med
, vol.6
, pp. 87-91
-
-
Hutchinson, M.1
Raff, U.2
-
3
-
-
0001823860
-
An algorithm for rapid image acquisition using multiple receiver coils
-
Amsterdam, The Netherlands. Abstract 1172
-
Kelton JR, Magin RL, Wright SM. An algorithm for rapid image acquisition using multiple receiver coils. In: Proceedings of the 8th Annual Meeting of SMRM, Amsterdam, The Netherlands, 1989. Abstract 1172.
-
(1989)
Proceedings of the 8th Annual Meeting of SMRM
-
-
Kelton, J.R.1
Magin, R.L.2
Wright, S.M.3
-
4
-
-
0027173207
-
Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
-
Carlson JW, Minemura T. Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. Magn Reson Med 1993;29:681-687.
-
(1993)
Magn Reson Med
, vol.29
, pp. 681-687
-
-
Carlson, J.W.1
Minemura, T.2
-
5
-
-
0027319233
-
Fast imaging using subencoding data sets from multiple detectors
-
Ra JB, Rim CY. Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 1993;30:142-145.
-
(1993)
Magn Reson Med
, vol.30
, pp. 142-145
-
-
Ra, J.B.1
Rim, C.Y.2
-
6
-
-
0029310690
-
Preliminary experimental evaluation of an inverse source imaging procedure using a decoupled coil detector array in magnetic resonance imaging
-
Kwiat D, Einav S. Preliminary experimental evaluation of an inverse source imaging procedure using a decoupled coil detector array in magnetic resonance imaging. Med Eng Phys 1995;17:257-263.
-
(1995)
Med Eng Phys
, vol.17
, pp. 257-263
-
-
Kwiat, D.1
Einav, S.2
-
7
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
8
-
-
0032425458
-
AUTO-SMASH: A self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics
-
Jakob PM, Griswold MA, Edelman RR, Sodickson DK. AUTO-SMASH: a self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics. MAGMA 1998;7:42-54.
-
(1998)
MAGMA
, vol.7
, pp. 42-54
-
-
Jakob, P.M.1
Griswold, M.A.2
Edelman, R.R.3
Sodickson, D.K.4
-
11
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
-
12
-
-
0033854213
-
Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
-
Kyriakos WE, Panych LP, Kacher DF, et al. Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med 2000;44:301-308.
-
(2000)
Magn Reson Med
, vol.44
, pp. 301-308
-
-
Kyriakos, W.E.1
Panych, L.P.2
Kacher, D.F.3
-
14
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM. The NMR phased array. Magn Reson Med 1990;16:192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
16
-
-
33746893087
-
A 32 channel receive-only phased array head coil for 3T with novel geodesic tiling geometry
-
Miami Beach, FL, USA. Abstract 679
-
Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL. A 32 channel receive-only phased array head coil for 3T with novel geodesic tiling geometry. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005. Abstract 679.
-
(2005)
Proceedings of the 13th Annual Meeting of ISMRM
-
-
Wiggins, G.C.1
Triantafyllou, C.2
Potthast, A.3
Reykowski, A.4
Nittka, M.5
Wald, L.L.6
-
17
-
-
33746916123
-
Autocalibrated parallel imaging with GRAPPA using a single prescan as reference data
-
Copenhagen, Denmark. Abstract 398
-
Breuer F, Blaimer M, Mueller M, Heidemann RM, Griswold M, Jakob P. Autocalibrated parallel imaging with GRAPPA using a single prescan as reference data. In: Proceedings of the 21st Annual Meeting of ESMRMB, Copenhagen, Denmark, 2004. Abstract 398.
-
(2004)
Proceedings of the 21st Annual Meeting of ESMRMB
-
-
Breuer, F.1
Blaimer, M.2
Mueller, M.3
Heidemann, R.M.4
Griswold, M.5
Jakob, P.6
-
19
-
-
24144469169
-
Improved data reconstruction method for GRAPPA
-
Wang Z, Wang J, Detre JA. Improved data reconstruction method for GRAPPA. Magn Reson Med 2005;54:738-742.
-
(2005)
Magn Reson Med
, vol.54
, pp. 738-742
-
-
Wang, Z.1
Wang, J.2
Detre, J.A.3
-
20
-
-
0037308718
-
Resolution enhancement in lung 1H imaging using parallel imaging methods
-
Heidemann RM, Griswold MA, Kiefer B, et al. Resolution enhancement in lung 1H imaging using parallel imaging methods. Magn Reson Med 2003;49:391-394.
-
(2003)
Magn Reson Med
, vol.49
, pp. 391-394
-
-
Heidemann, R.M.1
Griswold, M.A.2
Kiefer, B.3
|