메뉴 건너뛰기




Volumn 106, Issue 6, 2009, Pages 531-535

Evaluation of dynamic contour tonometry in keratoconus;Evaluierung der dynamischen konturtonometrie bei keratokonus

Author keywords

Corneal thickness; Dynamic contour tonometry; Goldmann applanation tonometry; Intraocular pressure; Keratoconus

Indexed keywords


EID: 67949111022     PISSN: 0941293X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00347-008-1812-1     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 33845904186 scopus 로고    scopus 로고
    • Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus
    • Barreto J Jr, Babic M, Murad R (2006) Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus. Clinics 61:511-514
    • (2006) Clinics , vol.61 , pp. 511-514
    • Barreto Jr, J.1    Babic, M.2    Murad, R.3
  • 2
    • 0031464637 scopus 로고    scopus 로고
    • Measuring intraocular pressure in keratoconus. Effect of the changed biomechanics
    • Böhm A, Kohlhaas M, Lerche RC et al. (1997) Measuring intraocular pressure in keratoconus. Effect of the changed biomechanics. Ophthalmologe 94:771-774
    • (1997) Ophthalmologe , vol.94 , pp. 771-774
    • Böhm, A.1    Kohlhaas, M.2    Lerche, R.C.3
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement beween two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement beween two methods of clinical measurement. Lancet 307-310
    • (1986) Lancet , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0029038603 scopus 로고
    • Comparing two methods of clinical measurement. A personal history
    • Bland JM, Altman DG (1995) Comparing two methods of clinical measurement. A personal history. Int J Epidemiol 24:7-14
    • (1995) Int J Epidemiol , vol.24 , pp. 7-14
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 22544486553 scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry over a wide range of central corneal thickness
    • Doyle A, Lachkar Y (1995) Comparison of dynamic contour tonometry with Goldmann applanation tonometry over a wide range of central corneal thickness. J Glaucoma 14:288-292
    • (1995) J Glaucoma , vol.14 , pp. 288-292
    • Doyle, A.1    Lachkar, Y.2
  • 6
    • 3042667876 scopus 로고    scopus 로고
    • Dynamic contour tonometry for post-LASIK intraocular pressure measurements
    • Duba I, Wirthlin AC (2004) Dynamic contour tonometry for post-LASIK intraocular pressure measurements. Klin Monatsbl Augenheilkd 221:347-350
    • (2004) Klin Monatsbl Augenheilkd , vol.221 , pp. 347-350
    • Duba, I.1    Wirthlin, A.C.2
  • 7
    • 70449195078 scopus 로고
    • Über Applanationstonometrie.
    • Goldmann H, Schmidt T (1957) Über Applanationstonometrie. Ophthalmologica 134:221-242
    • (1957) Ophthalmologica , vol.134 , pp. 221-242
    • Goldmann, H.1    Schmidt, T.2
  • 8
    • 0347355073 scopus 로고    scopus 로고
    • Central corneal thickness as a risk factor for advanced glaucoma damage
    • Herndon LW, Weizer JS, Stinnett SS (2004) Central corneal thickness as a risk factor for advanced glaucoma damage. Arch Ophthalmol 122:17-21
    • (2004) Arch Ophthalmol , vol.122 , pp. 17-21
    • Herndon, L.W.1    Weizer, J.S.2    Stinnett, S.S.3
  • 10
    • 4344659799 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldmann applanation tonometry
    • Kaufmann C, Bachmann LM, Thiel MA (2004) Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci 45:3118-3121
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 3118-3121
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 11
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • Kaufmann C, Bachmann LM, Thiel MA (2003) Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci 44:3790-3794
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3790-3794
    • Kaufmann, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 12
    • 27744519845 scopus 로고    scopus 로고
    • Clinical comparison of contour and applanation tonometry and their relationship to pachymetry
    • Kniestedt C, Lin S, Choe J et al. (2005) Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol 123:1532-1537
    • (2005) Arch Ophthalmol , vol.123 , pp. 1532-1537
    • Kniestedt, C.1    Lin, S.2    Choe, J.3
  • 13
    • 33646761304 scopus 로고    scopus 로고
    • Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data
    • Kniestedt C, Lin S, Choe J et al. (2006) Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data. Glaucoma 15:91-97
    • (2006) Glaucoma , vol.15 , pp. 91-97
    • Kniestedt, C.1    Lin, S.2    Choe, J.3
  • 14
    • 24944580479 scopus 로고    scopus 로고
    • Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states
    • Kniestedt C, Nee M, Stamper RL (2005) Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states. Graefes Arch Clin Exp Ophthalmol 243:763-767
    • (2005) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 763-767
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 15
    • 4444321895 scopus 로고    scopus 로고
    • Dynamic contour tonometry. A comparative study on human cadaver eyes
    • Kniestedt C, Nee M, Stamper RL (2004) Dynamic contour tonometry. A comparative study on human cadaver eyes. Arch Ophthalmol 122:1287-1293
    • (2004) Arch Ophthalmol , vol.122 , pp. 1287-1293
    • Kniestedt, C.1    Nee, M.2    Stamper, R.L.3
  • 16
    • 33645846918 scopus 로고    scopus 로고
    • Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry
    • Kohlhaas M, Boehm AG, Spoerl E et al. (2006) Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 124:471-476
    • (2006) Arch Ophthalmol , vol.124 , pp. 471-476
    • Kohlhaas, M.1    Boehm, A.G.2    Spoerl, E.3
  • 17
    • 0001534165 scopus 로고
    • Goldmann applanation tonometer
    • Moses RA (1958) Goldmann applanation tonometer. Am J Ophthalmol 46:865-869
    • (1958) Am J Ophthalmol , vol.46 , pp. 865-869
    • Moses, R.A.1
  • 18
    • 33751087202 scopus 로고    scopus 로고
    • Dynamic contour tonometry. A new way to assess intraocular pressure in ectatic corneas
    • Ozbek Z, Cohen EJ, Hammersmith KM et al. (2006) Dynamic contour tonometry. A new way to assess intraocular pressure in ectatic corneas. Cornea 25:890-894
    • (2006) Cornea , vol.25 , pp. 890-894
    • Ozbek, Z.1    Cohen, E.J.2    Hammersmith, K.M.3
  • 19
    • 24944580479 scopus 로고    scopus 로고
    • Dynamic contour tonometry versus Goldmann applanation tonometry: A comparative study
    • Pache M, Wilmsmeyer S, Lautebach S et al. (2004) Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study. Graefes Arch Clin Exp Ophthalmol 243:763-767
    • (2004) Graefes Arch Clin Exp Ophthalmol , vol.243 , pp. 763-767
    • Pache, M.1    Wilmsmeyer, S.2    Lautebach, S.3
  • 20
    • 30344436327 scopus 로고    scopus 로고
    • Intraocular pressure measurement - comparison of dynamic contour tonometry and Goldmann applanation tonometry
    • Schneider E, Grehn F (2006) Intraocular pressure measurement - comparison of dynamic contour tonometry and Goldmann applanation tonometry. J Glaucoma 15:2-6
    • (2006) J Glaucoma , vol.15 , pp. 2-6
    • Schneider, E.1    Grehn, F.2
  • 21
    • 67949107384 scopus 로고    scopus 로고
    • Dynamic contour tonometry
    • Grehn F, Stamper R eds, Springer, Heidelberg New York, pp
    • Schneider E, Kanngiesser HE, Kniestedt C (2006) Dynamic contour tonometry. In: Grehn F, Stamper R (eds) Glaucoma. Springer, Heidelberg New York, pp 47-63
    • (2006) Glaucoma , pp. 47-63
    • Schneider, E.1    Kanngiesser, H.E.2    Kniestedt, C.3
  • 22
    • 0031848594 scopus 로고    scopus 로고
    • Applanation tonometry an correction according to corneal thickness
    • Stodtmeister R (1998) Applanation tonometry an correction according to corneal thickness. Acta Ophthalmol Scand 76:319-324
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 319-324
    • Stodtmeister, R.1
  • 23
    • 33748790161 scopus 로고    scopus 로고
    • Evaluierung der dynamischen Konturtonometrie nach perforierender Keratoplastik.
    • Viestenz A, Langenbucher A, Seitz B,Viestenz A (2006) Evaluierung der dynamischen Konturtonometrie nach perforierender Keratoplastik. Ophthalmologe 103:773-776
    • (2006) Ophthalmologe , vol.103 , pp. 773-776
    • Viestenz, A.1    Langenbucher, A.2    Seitz, B.3    Viestenz, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.