메뉴 건너뛰기




Volumn 61, Issue 6, 2006, Pages 511-514

Dynamic contour tonometry and Goldman applanation tonometry in eyes with keratoconus

Author keywords

Applanation tonometry; Corneal thickness; Dynamic contour tonometry; Goldman; Intraocular pressure; Keratoconous

Indexed keywords

ADULT; ARTICLE; BIOMECHANICS; CASE CONTROL STUDY; FEMALE; HUMAN; INTRAOCULAR PRESSURE; KERATOCONUS; KERATOMETRY; MALE; METHODOLOGY; OCULOPLETHYSMOGRAPHY; PATHOPHYSIOLOGY; PHYSIOLOGY; PROSPECTIVE STUDY; REPRODUCIBILITY; STANDARD;

EID: 33845904186     PISSN: 18075932     EISSN: None     Source Type: Journal    
DOI: 10.1590/S1807-59322006000600004     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 70449195078 scopus 로고    scopus 로고
    • Goldmann H, Schmidt T. Uber applanationstonometrie. Ophthalmologica. 1957;134:221-42.
    • Goldmann H, Schmidt T. Uber applanationstonometrie. Ophthalmologica. 1957;134:221-42.
  • 2
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 3
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • Ehlers N, Bransen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 1975;53:34-43.
    • (1975) Acta Ophthalmol , vol.53 , pp. 34-43
    • Ehlers, N.1    Bransen, T.2    Sperling, S.3
  • 4
    • 0036235038 scopus 로고    scopus 로고
    • Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer and Tono-pen
    • Bhan A, Browning AC, Shah S, Hamilton R, Dave D, Dua HS. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer and Tono-pen. Invest Ophthalmol Vis Sci. 2002;43:1389-92.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 1389-1392
    • Bhan, A.1    Browning, A.C.2    Shah, S.3    Hamilton, R.4    Dave, D.5    Dua, H.S.6
  • 5
    • 13844318981 scopus 로고    scopus 로고
    • Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
    • Siganos DS, Papasterigiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg. 2004;30:746-51.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 746-751
    • Siganos, D.S.1    Papasterigiou, G.I.2    Moedas, C.3
  • 6
    • 22544486553 scopus 로고    scopus 로고
    • Comparison of dynamic contour tonometry with Goldman applanation tonometry over a wide range of central corneal thickness
    • Doyle A, Lachkar Y. Comparison of dynamic contour tonometry with Goldman applanation tonometry over a wide range of central corneal thickness. Journal of Glaucoma. 2005;14:288-92.
    • (2005) Journal of Glaucoma , vol.14 , pp. 288-292
    • Doyle, A.1    Lachkar, Y.2
  • 7
    • 0041360373 scopus 로고    scopus 로고
    • Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis
    • Kaufman C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2003;44:3790-4.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 3790-3794
    • Kaufman, C.1    Bachmann, L.M.2    Thiel, M.A.3
  • 8
    • 0029744329 scopus 로고    scopus 로고
    • Inferior steepening is associated with thinning of the inferotemporal cornea
    • Colin J, Sale Y, Malet F, Cochener B. Inferior steepening is associated with thinning of the inferotemporal cornea. J Refract Surg. 1996;12:697-9.
    • (1996) J Refract Surg , vol.12 , pp. 697-699
    • Colin, J.1    Sale, Y.2    Malet, F.3    Cochener, B.4
  • 9
    • 0031464637 scopus 로고    scopus 로고
    • Measuring intraocular pressure in keratoconus. Effect of the changed biomechanics
    • Bohm A, Kohlhaas M, Lerche RC, Bischoff B, Richard G. Measuring intraocular pressure in keratoconus. Effect of the changed biomechanics. Ophthalmologe. 1997;94:771-4.
    • (1997) Ophthalmologe , vol.94 , pp. 771-774
    • Bohm, A.1    Kohlhaas, M.2    Lerche, R.C.3    Bischoff, B.4    Richard, G.5
  • 11
    • 0030026336 scopus 로고    scopus 로고
    • Standardizing the measurement of intraocular pressure for clinical research
    • Kass MA. Standardizing the measurement of intraocular pressure for clinical research. Ophthalmology. 1996;103:183-5.
    • (1996) Ophthalmology , vol.103 , pp. 183-185
    • Kass, M.A.1
  • 12
    • 0034803965 scopus 로고    scopus 로고
    • Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS)
    • Brandt JD, Beiser JA, Gordon MO, Kass MA. Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology. 2001;108:1779-88.
    • (2001) Ophthalmology , vol.108 , pp. 1779-1788
    • Brandt, J.D.1    Beiser, J.A.2    Gordon, M.O.3    Kass, M.A.4
  • 13
    • 0016663381 scopus 로고
    • Applanation tonometry and central corneal thickness
    • Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 1975;53:1974-83.
    • (1975) Acta Ophthalmol , vol.53 , pp. 1974-1983
    • Ehlers, N.1    Bramsen, T.2    Sperling, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.