메뉴 건너뛰기




Volumn 133, Issue 4, 2008, Pages 621-627

Mini-implant anchorage for the orthodontic practitioner

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL PROTOCOL; ELECTRONICS; EQUIPMENT; FOOD AND DRUG ADMINISTRATION; HUMAN; INJURY; INSTRUMENTATION; METHODOLOGY; ORTHODONTICS; PERIODONTAL LIGAMENT; PRIVATE PRACTICE; SAFETY; TOOTH IMPLANTATION; UNITED STATES;

EID: 41649089946     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2007.03.022     Document Type: Article
Times cited : (72)

References (28)
  • 1
    • 2842557580 scopus 로고
    • A study of orthodontic anchorage possibilities in basal bone
    • Gainsforth B.L., and Higley L.B. A study of orthodontic anchorage possibilities in basal bone. Am J Orthod Oral Surg 31 (1945) 406-417
    • (1945) Am J Orthod Oral Surg , vol.31 , pp. 406-417
    • Gainsforth, B.L.1    Higley, L.B.2
  • 2
    • 0014635279 scopus 로고
    • The endosseous blade implant and its use in orthodontics
    • Linkow L.I. The endosseous blade implant and its use in orthodontics. Int J Orthod 7 (1969) 149-154
    • (1969) Int J Orthod , vol.7 , pp. 149-154
    • Linkow, L.I.1
  • 3
    • 0014902718 scopus 로고
    • Implanto-orthodontics
    • Linkow L.I. Implanto-orthodontics. J Clin Orthod 4 (1970) 685-690
    • (1970) J Clin Orthod , vol.4 , pp. 685-690
    • Linkow, L.I.1
  • 4
    • 0020739585 scopus 로고
    • The possibility of skeletal anchorage
    • Creekmore T.D., and Eklund M.K. The possibility of skeletal anchorage. J Clin Orthod 17 (1983) 266-269
    • (1983) J Clin Orthod , vol.17 , pp. 266-269
    • Creekmore, T.D.1    Eklund, M.K.2
  • 7
    • 0025333345 scopus 로고
    • Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site
    • Roberts W.E., Marshall K.J., and Mozsary P.G. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site. Angle Orthod 60 (1990) 135-152
    • (1990) Angle Orthod , vol.60 , pp. 135-152
    • Roberts, W.E.1    Marshall, K.J.2    Mozsary, P.G.3
  • 8
    • 0029263743 scopus 로고
    • A new device for absolute anchorage for orthodontics
    • Block M.S., and Hoffman D.R. A new device for absolute anchorage for orthodontics. Am J Orthod Dentofacial Orthop 107 (1995) 251-258
    • (1995) Am J Orthod Dentofacial Orthop , vol.107 , pp. 251-258
    • Block, M.S.1    Hoffman, D.R.2
  • 9
    • 0030162071 scopus 로고    scopus 로고
    • The orthosystem-a new implant system for orthodontic anchorage in the palate
    • Wehrbein H., Glatzmaier J., Mundwiller U., and Diedrich P. The orthosystem-a new implant system for orthodontic anchorage in the palate. J Orofac Orthop 57 (1996) 142-153
    • (1996) J Orofac Orthop , vol.57 , pp. 142-153
    • Wehrbein, H.1    Glatzmaier, J.2    Mundwiller, U.3    Diedrich, P.4
  • 10
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 12
    • 0033290405 scopus 로고    scopus 로고
    • Dr. Junji Sugawara on the skeletal anchorage system. Interview by Dr. Larry W. White
    • Sugawara J. Dr. Junji Sugawara on the skeletal anchorage system. Interview by Dr. Larry W. White. J Clin Orthod 33 (1999) 689-696
    • (1999) J Clin Orthod , vol.33 , pp. 689-696
    • Sugawara, J.1
  • 13
    • 7044264818 scopus 로고    scopus 로고
    • Sliding mechanics with microscrew implant anchorage
    • Park H.S., and Kwon T.G. Sliding mechanics with microscrew implant anchorage. Angle Orthod 74 (2004) 703-710
    • (2004) Angle Orthod , vol.74 , pp. 703-710
    • Park, H.S.1    Kwon, T.G.2
  • 15
    • 33746792428 scopus 로고    scopus 로고
    • Mini-implant anchorage for maxillary canine retraction: a pilot study
    • Herman R.J., Currier G.F., and Miyake A. Mini-implant anchorage for maxillary canine retraction: a pilot study. Am J Orthod Dentofacial Orthop 130 (2006) 228-235
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 228-235
    • Herman, R.J.1    Currier, G.F.2    Miyake, A.3
  • 16
    • 33846075297 scopus 로고    scopus 로고
    • Unusual extraction treatment in Class II Division 1 using C-orthodontic mini-implants
    • Chung K.R., Cho J.H., Kim S.H., Kook Y.A., and Cozzani M. Unusual extraction treatment in Class II Division 1 using C-orthodontic mini-implants. Angle Orthod 77 (2007) 155-166
    • (2007) Angle Orthod , vol.77 , pp. 155-166
    • Chung, K.R.1    Cho, J.H.2    Kim, S.H.3    Kook, Y.A.4    Cozzani, M.5
  • 17
    • 4444308807 scopus 로고    scopus 로고
    • Severe anterior open-bite case treated using titanium screw anchorage
    • Kuroda S., Katayama A., and Takano-Yamamoto T. Severe anterior open-bite case treated using titanium screw anchorage. Angle Orthod 74 (2004) 558-567
    • (2004) Angle Orthod , vol.74 , pp. 558-567
    • Kuroda, S.1    Katayama, A.2    Takano-Yamamoto, T.3
  • 18
    • 3242673373 scopus 로고    scopus 로고
    • The use of skeletal anchorage in open bite treatment: a cephalometric evaluation
    • Erverdi N., Keles A., and Nanda R. The use of skeletal anchorage in open bite treatment: a cephalometric evaluation. Angle Orthod 74 (2004) 381-390
    • (2004) Angle Orthod , vol.74 , pp. 381-390
    • Erverdi, N.1    Keles, A.2    Nanda, R.3
  • 19
    • 18244387213 scopus 로고    scopus 로고
    • A mini-implant for orthodontic anchorage in a deep overbite case
    • Ohnishi H., Yagi T., Yasuda Y., and Takada K. A mini-implant for orthodontic anchorage in a deep overbite case. Angle Orthod 75 (2005) 444-452
    • (2005) Angle Orthod , vol.75 , pp. 444-452
    • Ohnishi, H.1    Yagi, T.2    Yasuda, Y.3    Takada, K.4
  • 20
    • 33747022474 scopus 로고    scopus 로고
    • Correction of a canted occlusal plane with miniscrews in a patient with facial asymmetry
    • Jeon Y.J., Kim Y.H., Son W.S., and Hans M.G. Correction of a canted occlusal plane with miniscrews in a patient with facial asymmetry. Am J Orthod Dentofacial Orthop 130 (2006) 244-252
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 244-252
    • Jeon, Y.J.1    Kim, Y.H.2    Son, W.S.3    Hans, M.G.4
  • 21
    • 3042596572 scopus 로고    scopus 로고
    • Treatment of ectopic mandibular second molar with titanium miniscrews
    • Giancotti A., Arcuri C., and Barlattani A. Treatment of ectopic mandibular second molar with titanium miniscrews. Am J Orthod Dentofacial Orthop 126 (2004) 113-117
    • (2004) Am J Orthod Dentofacial Orthop , vol.126 , pp. 113-117
    • Giancotti, A.1    Arcuri, C.2    Barlattani, A.3
  • 22
    • 4444257684 scopus 로고    scopus 로고
    • Intrusion of the overerupted upper left first and second molars by mini-implants with partial-fixed orthodontic appliances: a case report
    • Yao C.C., Wu C.B., Wu H.Y., Kok S.H., Chang H.F., and Chen Y.J. Intrusion of the overerupted upper left first and second molars by mini-implants with partial-fixed orthodontic appliances: a case report. Angle Orthod 74 (2004) 550-557
    • (2004) Angle Orthod , vol.74 , pp. 550-557
    • Yao, C.C.1    Wu, C.B.2    Wu, H.Y.3    Kok, S.H.4    Chang, H.F.5    Chen, Y.J.6
  • 23
    • 33646166175 scopus 로고    scopus 로고
    • Image analysis and superimposition of 3-dimensional cone-beam computed tomography models
    • Cevidanes L.H., Styner M.A., and Proffit W.R. Image analysis and superimposition of 3-dimensional cone-beam computed tomography models. Am J Orthod Dentofacial Orthop 129 (2006) 611-618
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , pp. 611-618
    • Cevidanes, L.H.1    Styner, M.A.2    Proffit, W.R.3
  • 25
    • 33744458766 scopus 로고    scopus 로고
    • Parameters affecting primary stability of orthodontic mini-implants
    • Wilmes B., Rademacher C., Olthoff G., and Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 6 (2006) 162-174
    • (2006) J Orofac Orthop , vol.6 , pp. 162-174
    • Wilmes, B.1    Rademacher, C.2    Olthoff, G.3    Drescher, D.4
  • 26
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S.J., Tseng I.Y., Lee J.J., and Kok S.H. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 19 (2004) 100-106
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100-106
    • Cheng, S.J.1    Tseng, I.Y.2    Lee, J.J.3    Kok, S.H.4
  • 27
    • 33745835122 scopus 로고    scopus 로고
    • Factors affecting the clinical success of screw implants used as orthodontic anchorage
    • Park H.S., Jeong S.H., and Kwon O.W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 18-25
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 18-25
    • Park, H.S.1    Jeong, S.H.2    Kwon, O.W.3
  • 28
    • 14544272341 scopus 로고    scopus 로고
    • Miniscrew implants: the spider screw anchorage system
    • Maino B.G., Mura P., and Bednar J. Miniscrew implants: the spider screw anchorage system. Semin Orthod 11 (2005) 40-46
    • (2005) Semin Orthod , vol.11 , pp. 40-46
    • Maino, B.G.1    Mura, P.2    Bednar, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.