메뉴 건너뛰기




Volumn 28, Issue 6, 2009, Pages 537-541

Comparison of ICG thoracic bioimpedance cardiac output monitoring system in patients undergoing cardiac surgery with pulmonary artery cardiac output measurements;Comparaison des valeurs de débit cardiaque obtenues à l'aide d'un nouveau système d'impédancemétrie thoracique avec les données du cathéter artériel pulmonaire en postopératoire de chirurgie cardiaque

Author keywords

Bioimpedance; Cardiac output; Cardiac surgery; Haemodynamic; Monitoring; Non invasive; Statistics

Indexed keywords

ACCURACY; ADULT; ANALYTICAL EQUIPMENT; ANALYTICAL ERROR; ARTICLE; CALIBRATION; CLINICAL ARTICLE; CONTROLLED STUDY; HEART OUTPUT MEASUREMENT; HEART SURGERY; HUMAN; IMPEDANCE; INTENSIVE CARE UNIT; MONITOR; PATIENT MONITORING; POSTOPERATIVE PERIOD; PROSPECTIVE STUDY; PULMONARY ARTERY CATHETER; REFERENCE VALUE; THERMODILUTION;

EID: 67649378400     PISSN: 07507658     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.annfar.2009.04.010     Document Type: Article
Times cited : (9)

References (35)
  • 1
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
    • Connors Jr. A.F., Speroff T., Dawson N.V., Thomas C., Harrell Jr. F.E., Wagner D., et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 276 (1996) 889-897
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors Jr., A.F.1    Speroff, T.2    Dawson, N.V.3    Thomas, C.4    Harrell Jr., F.E.5    Wagner, D.6
  • 2
    • 0345374592 scopus 로고    scopus 로고
    • Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial
    • Richard C., Warszawski J., Anguel N., Deye N., Combes A., Barnoud D., et al. Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 290 (2003) 2713-2720
    • (2003) JAMA , vol.290 , pp. 2713-2720
    • Richard, C.1    Warszawski, J.2    Anguel, N.3    Deye, N.4    Combes, A.5    Barnoud, D.6
  • 3
    • 37549020378 scopus 로고    scopus 로고
    • Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2008
    • Dellinger R.P., Levy M.M., Carlet J.M., Bion J., Parker M.M., Jaeschke R., et al. Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2008. Crit Care Med 36 (2008) 296-327
    • (2008) Crit Care Med , vol.36 , pp. 296-327
    • Dellinger, R.P.1    Levy, M.M.2    Carlet, J.M.3    Bion, J.4    Parker, M.M.5    Jaeschke, R.6
  • 4
    • 33846460037 scopus 로고    scopus 로고
    • Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients
    • Sander M., von Heymann C., Foer A., von Dossow V., Grosse J., Dushe S., et al. Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients. Crit Care 9 (2005) R729-R734
    • (2005) Crit Care , vol.9
    • Sander, M.1    von Heymann, C.2    Foer, A.3    von Dossow, V.4    Grosse, J.5    Dushe, S.6
  • 6
    • 0032817727 scopus 로고    scopus 로고
    • Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting
    • Buhre W., Weyland A., Kazmaier S., Hanekop G.G., Baryalei M.M., Sydow M., et al. Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting. J Cardiothorac Vasc Anesth 13 (1999) 437-440
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 437-440
    • Buhre, W.1    Weyland, A.2    Kazmaier, S.3    Hanekop, G.G.4    Baryalei, M.M.5    Sydow, M.6
  • 8
    • 0036198399 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique
    • Della Rocca G., Costa M.G., Pompei L., Coccia C., and Pietropaoli P. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 88 (2002) 350-356
    • (2002) Br J Anaesth , vol.88 , pp. 350-356
    • Della Rocca, G.1    Costa, M.G.2    Pompei, L.3    Coccia, C.4    Pietropaoli, P.5
  • 9
    • 0031001405 scopus 로고    scopus 로고
    • Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow
    • de Abreu M.G., Quintel M., Ragaller M., and Albrecht D.M. Partial carbon dioxide rebreathing: a reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow. Crit Care Med 25 (1997) 675-683
    • (1997) Crit Care Med , vol.25 , pp. 675-683
    • de Abreu, M.G.1    Quintel, M.2    Ragaller, M.3    Albrecht, D.M.4
  • 10
    • 14844354490 scopus 로고    scopus 로고
    • Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
    • Tan H.L., Pinder M., Parsons R., Roberts B., and van Heerden P.V. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth 94 (2005) 287-291
    • (2005) Br J Anaesth , vol.94 , pp. 287-291
    • Tan, H.L.1    Pinder, M.2    Parsons, R.3    Roberts, B.4    van Heerden, P.V.5
  • 11
    • 33747867362 scopus 로고
    • Über ein neues verfahren zur darstellung der herztätigkeit (dielektrographie)
    • Atzler E., and Lehmann G. Über ein neues verfahren zur darstellung der herztätigkeit (dielektrographie). Arbeitsphysiol 5 (1932) 636-680
    • (1932) Arbeitsphysiol , vol.5 , pp. 636-680
    • Atzler, E.1    Lehmann, G.2
  • 13
    • 0028000417 scopus 로고
    • Thoracic electrical bioimpedance measurements of cardiac output
    • Sramek B.B. Thoracic electrical bioimpedance measurements of cardiac output. Crit Care Med 22 (1994) 1337-1339
    • (1994) Crit Care Med , vol.22 , pp. 1337-1339
    • Sramek, B.B.1
  • 14
    • 33747840723 scopus 로고    scopus 로고
    • Non-invasive beat-to-beat cardiac output monitoring by an improved method of tranthoracic bioimpedance measurement
    • Fortin J., Habenbacher W., Heller A., Hacker A., Grüllenberger R., Innerhofer J., et al. Non-invasive beat-to-beat cardiac output monitoring by an improved method of tranthoracic bioimpedance measurement. Comput Biol Med 36 (2006) 1186-1203
    • (2006) Comput Biol Med , vol.36 , pp. 1186-1203
    • Fortin, J.1    Habenbacher, W.2    Heller, A.3    Hacker, A.4    Grüllenberger, R.5    Innerhofer, J.6
  • 15
    • 0026538331 scopus 로고
    • A bedside index assessing the reliability of pulmonary occlusion pressure measurements during mechanical ventilation with positive end-expiratory pressure
    • Teboul J.L., Besbes M., Andrivet P., Axler O., Douguet D., Zelter M., et al. A bedside index assessing the reliability of pulmonary occlusion pressure measurements during mechanical ventilation with positive end-expiratory pressure. J Crit Care 7 (1992) 22-29
    • (1992) J Crit Care , vol.7 , pp. 22-29
    • Teboul, J.L.1    Besbes, M.2    Andrivet, P.3    Axler, O.4    Douguet, D.5    Zelter, M.6
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurements techniques
    • Critchley L.A., and Critchley J.A. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurements techniques. J Clin Monit Comput 15 (1999) 85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 18
    • 36649018972 scopus 로고    scopus 로고
    • Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements
    • Cannesson M., Attof Y., Rosamel P., Joseph P., Bastien O., and Lehot J.J. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol (2007) 1-8
    • (2007) Eur J Anaesthesiol , pp. 1-8
    • Cannesson, M.1    Attof, Y.2    Rosamel, P.3    Joseph, P.4    Bastien, O.5    Lehot, J.J.6
  • 19
    • 26944486636 scopus 로고    scopus 로고
    • Noninvasive techniques for measurements of cardiac output
    • Cholley B.P., and Payen D. Noninvasive techniques for measurements of cardiac output. Curr Opin Crit Care 11 (2005) 424-429
    • (2005) Curr Opin Crit Care , vol.11 , pp. 424-429
    • Cholley, B.P.1    Payen, D.2
  • 20
    • 2442688872 scopus 로고    scopus 로고
    • Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications
    • Moshkovitz Y., Kaluski E., Milo O., Vered Z., and Cotter G. Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications. Curr Opin Cardiol 19 (2004) 229-237
    • (2004) Curr Opin Cardiol , vol.19 , pp. 229-237
    • Moshkovitz, Y.1    Kaluski, E.2    Milo, O.3    Vered, Z.4    Cotter, G.5
  • 21
    • 27744490939 scopus 로고    scopus 로고
    • Stroke volume equation for impedance cardiography
    • Bernstein D.P., and Lemmens H.J. Stroke volume equation for impedance cardiography. Med Biol Eng Comput 43 (2005) 443-450
    • (2005) Med Biol Eng Comput , vol.43 , pp. 443-450
    • Bernstein, D.P.1    Lemmens, H.J.2
  • 22
    • 36448981768 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements
    • Heringlake M., Handke U., Hanke T., Eberhardt F., Schumacher J., Gehring H., et al. Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements. Intensive Care Med 33 (2007) 2168-2172
    • (2007) Intensive Care Med , vol.33 , pp. 2168-2172
    • Heringlake, M.1    Handke, U.2    Hanke, T.3    Eberhardt, F.4    Schumacher, J.5    Gehring, H.6
  • 23
    • 33751531236 scopus 로고    scopus 로고
    • Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution
    • Suttner S., Schollhorn T., Boldt J., Mayer J., Rohm K.D., Lang K., et al. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution. Intensive Care Med 32 (2006) 2053-2058
    • (2006) Intensive Care Med , vol.32 , pp. 2053-2058
    • Suttner, S.1    Schollhorn, T.2    Boldt, J.3    Mayer, J.4    Rohm, K.D.5    Lang, K.6
  • 24
    • 0036171177 scopus 로고    scopus 로고
    • Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery
    • Sageman W.S., Riffenburgh R.H., and Spiess B.D. Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery. J Cardiothorac Vasc Anesth 16 (2002) 8-14
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 8-14
    • Sageman, W.S.1    Riffenburgh, R.H.2    Spiess, B.D.3
  • 25
    • 0029056066 scopus 로고
    • Cardiac output measurement: lack of agreement between thermodilution and thoracic electric bioimpedance in two clinical settings
    • Atallah M.M., and Demain A.D. Cardiac output measurement: lack of agreement between thermodilution and thoracic electric bioimpedance in two clinical settings. J Clin Anesth 7 (1995) 182-185
    • (1995) J Clin Anesth , vol.7 , pp. 182-185
    • Atallah, M.M.1    Demain, A.D.2
  • 27
    • 0025786660 scopus 로고
    • Bioimpedance versus thermodilution cardiac output measurements: the Biomed NCCOM3 after coronary bypass surgery
    • Thomas A.N., Ryan J., Doran B.R., and Pollard B.J. Bioimpedance versus thermodilution cardiac output measurements: the Biomed NCCOM3 after coronary bypass surgery. Intensive Care Med 17 (1991) 383-386
    • (1991) Intensive Care Med , vol.17 , pp. 383-386
    • Thomas, A.N.1    Ryan, J.2    Doran, B.R.3    Pollard, B.J.4
  • 28
    • 0027303341 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients
    • Sageman W.S., and Amundson D.E. Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients. Crit Care Med 21 (1993) 1139-1142
    • (1993) Crit Care Med , vol.21 , pp. 1139-1142
    • Sageman, W.S.1    Amundson, D.E.2
  • 29
    • 0035998335 scopus 로고    scopus 로고
    • Equipment review: new techniques for cardiac output measurment-oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis
    • Berton C., and Cholley B. Equipment review: new techniques for cardiac output measurment-oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis. Crit Care 6 (2002) 216-221
    • (2002) Crit Care , vol.6 , pp. 216-221
    • Berton, C.1    Cholley, B.2
  • 30
    • 0042344943 scopus 로고    scopus 로고
    • 2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery
    • 2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery. Anesthesiology 99 (2003) 283-288
    • (2003) Anesthesiology , vol.99 , pp. 283-288
    • Kotake, Y.1    Moriyama, K.2    Innami, Y.3    Shimizu, H.4    Ueda, T.5    Morisaki, H.6
  • 31
    • 0036152801 scopus 로고    scopus 로고
    • Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability
    • Godje O., Hoke K., Goetz A.E., Felbinger T.W., Reuter D.A., Reichart B., et al. Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Crit Care Med 30 (2002) 52-58
    • (2002) Crit Care Med , vol.30 , pp. 52-58
    • Godje, O.1    Hoke, K.2    Goetz, A.E.3    Felbinger, T.W.4    Reuter, D.A.5    Reichart, B.6
  • 32
    • 0031839152 scopus 로고    scopus 로고
    • Clinical evaluation of the Abbot Qvue-OptiQ continuous cardiac output system in critically ill medical patients
    • Monchi M., Thebert D., Cariou A., Bellenfant F., Joly L.M., Brunet F., et al. Clinical evaluation of the Abbot Qvue-OptiQ continuous cardiac output system in critically ill medical patients. J Crit Care 13 (1998) 91-95
    • (1998) J Crit Care , vol.13 , pp. 91-95
    • Monchi, M.1    Thebert, D.2    Cariou, A.3    Bellenfant, F.4    Joly, L.M.5    Brunet, F.6
  • 33
    • 24944439222 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement
    • Pittman J., Bar-Yosef S., SumPing J., Sherwood M., and Mark J. Continuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement. Crit Care Med 33 (2005) 2015-2021
    • (2005) Crit Care Med , vol.33 , pp. 2015-2021
    • Pittman, J.1    Bar-Yosef, S.2    SumPing, J.3    Sherwood, M.4    Mark, J.5
  • 35
    • 33646870345 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring after cardiopulmonary bypass: a comparison with bolus thermodilution measurements
    • Bendjelid K., Schutz N., Suter P.M., and Romand J.A. Continuous cardiac output monitoring after cardiopulmonary bypass: a comparison with bolus thermodilution measurements. Intensive Care Med 32 (2006) 919-922
    • (2006) Intensive Care Med , vol.32 , pp. 919-922
    • Bendjelid, K.1    Schutz, N.2    Suter, P.M.3    Romand, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.