메뉴 건너뛰기




Volumn 32, Issue 12, 2006, Pages 2053-2058

Erratum: Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: A comparison with pulmonary artery thermodilution (Intensive Care Medicine (2006) 32 (2053-2058) DOI: 10.1007/s00134-006-0409-x);Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: A comparison with pulmonary artery thermodilution

Author keywords

Cardiac output; Cardiac surgery; Hemodynamic monitoring; Pulmonary artery catheter; Thermodilution; Thoracic electrical bioimpedance

Indexed keywords

ACCURACY; AGED; ALGORITHM; ARTERY CATHETERIZATION; ARTICLE; ARTIFICIAL VENTILATION; CALCULATION; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; DEVICE; ELECTIVE SURGERY; FEMALE; HEART OUTPUT; HEART SURGERY; HEMODYNAMICS; HOSPITAL ADMISSION; HUMAN; IMPEDANCE CARDIOGRAPHY; INTENSIVE CARE UNIT; INTERNAL BIAS; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; NON INVASIVE PROCEDURE; OBSERVATIONAL STUDY; PROSPECTIVE STUDY; PULMONARY ARTERY; STATISTICAL SIGNIFICANCE; THERMODILUTION; THORACIC ELECTRICAL BIOIMPEDANCE; UNIVERSITY HOSPITAL;

EID: 33751531236     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-011-2219-z     Document Type: Erratum
Times cited : (75)

References (18)
  • 1
    • 0027158307 scopus 로고
    • Measurement of cardiac output with the Quantascope, a novel Doppler device: Comparison with thermodilution
    • Cross SJ, Lee HS, Jennings K, Rawles J (1993) Measurement of cardiac output with the Quantascope, a novel Doppler device: comparison with thermodilution. Eur Heart J 14:809-811
    • (1993) Eur Heart J , vol.14 , pp. 809-811
    • Cross, S.J.1    Lee, H.S.2    Jennings, K.3    Rawles, J.4
  • 2
    • 0024077559 scopus 로고
    • Noninvasive measurement of cardiac output using partial CO2 rebreathing
    • Capek JM, Roy RJ (1988) Noninvasive measurement of cardiac output using partial CO2 rebreathing. IEEE Trans Biomed Eng 35:653-661
    • (1988) IEEE Trans Biomed Eng , vol.35 , pp. 653-661
    • Capek, J.M.1    Roy, R.J.2
  • 3
    • 0030832772 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement: A comparison with thermodilution
    • Linton R, Band D, O'Brien T, Jonas M, Leach R (1997) Lithium dilution cardiac output measurement: a comparison with thermodilution. Crit Care Med 25:1796-1800
    • (1997) Crit Care Med , vol.25 , pp. 1796-1800
    • Linton, R.1    Band, D.2    O'Brien, T.3    Jonas, M.4    Leach, R.5
  • 6
    • 2442688872 scopus 로고    scopus 로고
    • Recent developments in cardiac output determination by bioimpedance: Comparison with invasive cardiac output and potential cardiovascular applications
    • Moshkovitz Y, Kaluski E, Milo O, Vered Z, Cotter G (2004) Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications. Curr Opin Cardiol 19:229-237
    • (2004) Curr Opin Cardiol , vol.19 , pp. 229-237
    • Moshkovitz, Y.1    Kaluski, E.2    Milo, O.3    Vered, Z.4    Cotter, G.5
  • 7
    • 0031016222 scopus 로고    scopus 로고
    • Impedance cardiography accurately measures cardiac output during exercise in children with cystic fibrosis
    • Pianosi PT (1997) Impedance cardiography accurately measures cardiac output during exercise in children with cystic fibrosis. Chest 111:333-337
    • (1997) Chest , vol.111 , pp. 333-337
    • Pianosi, P.T.1
  • 8
    • 0022975760 scopus 로고
    • Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients
    • Appel PL, Kram HB, Mackabee J, Fleming AW, Shoemaker WC (1986) Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med 14:933-935
    • (1986) Crit Care Med , vol.14 , pp. 933-935
    • Appel, P.L.1    Kram, H.B.2    Mackabee, J.3    Fleming, A.W.4    Shoemaker, W.C.5
  • 9
    • 0027303341 scopus 로고
    • Thoracic electrical bioimpedance measurements of cardiac output in postaortocoronary bypass patients
    • Sageman WS, Amundson DE (1993) Thoracic electrical bioimpedance measurements of cardiac output in postaortocoronary bypass patients. Crit Care Med 21:1139-1142
    • (1993) Crit Care Med , vol.21 , pp. 1139-1142
    • Sageman, W.S.1    Amundson, D.E.2
  • 10
    • 0028839518 scopus 로고
    • Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution
    • Doering L, Lum E, Dracup K, Friedman A (1995) Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution. Crit Care Med 23:1667-1673
    • (1995) Crit Care Med , vol.23 , pp. 1667-1673
    • Doering, L.1    Lum, E.2    Dracup, K.3    Friedman, A.4
  • 11
    • 0027458319 scopus 로고
    • Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis
    • Young JD, McQuillan P (1993) Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis. Br J Anaesth 70:58-62
    • (1993) Br J Anaesth , vol.70 , pp. 58-62
    • Young, J.D.1    McQuillan, P.2
  • 12
    • 0033170999 scopus 로고    scopus 로고
    • Electrophysiologic principles and theory of stroke volume determination by thoracic electrical bioimpedance
    • Osypka MJ, Bernstein DP (1999) Electrophysiologic principles and theory of stroke volume determination by thoracic electrical bioimpedance. AACN Clin Issues 10:385-399
    • (1999) AACN Clin Issues , vol.10 , pp. 385-399
    • Osypka, M.J.1    Bernstein, D.P.2
  • 13
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurements
    • Bland JM, Altman DG (1986) Statistical method for assessing agreement between two methods of clinical measurements. Lancet I:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
    • Bernstein DP (1986) A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale. Crit Care Med 14:904-909
    • (1986) Crit Care Med , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 16
  • 17
    • 0021347646 scopus 로고
    • Frequency of technical problems encountered in the measurement of pulmonary artery wedge pressure
    • Morris AH, Chapman RH, Gardner RM (1984) Frequency of technical problems encountered in the measurement of pulmonary artery wedge pressure. Crit Care Med 12:164-170
    • (1984) Crit Care Med , vol.12 , pp. 164-170
    • Morris, A.H.1    Chapman, R.H.2    Gardner, R.M.3
  • 18
    • 0034779613 scopus 로고    scopus 로고
    • A rose by any other name: Cardiac output
    • Pinsky MR (2001) A rose by any other name: Cardiac output. Crit Care Med 29:2021-2022
    • (2001) Crit Care Med , vol.29 , pp. 2021-2022
    • Pinsky, M.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.