-
1
-
-
0034426959
-
Clinical decision making in patients with congestive heart failure: the role of thoracic electrical bioimpedance
-
Wright R.F., and Gilbert J. Clinical decision making in patients with congestive heart failure: the role of thoracic electrical bioimpedance. Congest. Heart Fail 6 2 (2000) 27-31
-
(2000)
Congest. Heart Fail
, vol.6
, Issue.2
, pp. 27-31
-
-
Wright, R.F.1
Gilbert, J.2
-
2
-
-
3042785009
-
Evaluation of impedance cardiography as an alternative to pulmonary artery catherization in critically ill patients
-
Silver M., Cianci P., Brennan S., Longeran-Thomas H., and Ahmad F. Evaluation of impedance cardiography as an alternative to pulmonary artery catherization in critically ill patients. Congest. Heart Fail 10 2 Suppl. 2 (2004) 17-21
-
(2004)
Congest. Heart Fail
, vol.10
, Issue.2 SUPPL. 2
, pp. 17-21
-
-
Silver, M.1
Cianci, P.2
Brennan, S.3
Longeran-Thomas, H.4
Ahmad, F.5
-
3
-
-
3042780433
-
Use of impedance cardiography in non-invasive hemodynamics to aid decision making in the initiation and titration of neurohormonal agents
-
Summers R., Parrott C., Quale C., and Lewi D. Use of impedance cardiography in non-invasive hemodynamics to aid decision making in the initiation and titration of neurohormonal agents. Congest. Heart Fail 10 2 Suppl. 2 (2004) 28-31
-
(2004)
Congest. Heart Fail
, vol.10
, Issue.2 SUPPL. 2
, pp. 28-31
-
-
Summers, R.1
Parrott, C.2
Quale, C.3
Lewi, D.4
-
4
-
-
0034427050
-
Impedance cardiography: noninvasive measurement of cardiac stroke volume and thoracic fluid content
-
Strobeck J.E., Silver M., and Ventura H. Impedance cardiography: noninvasive measurement of cardiac stroke volume and thoracic fluid content. Congest. Heart Fail 6 2 (2000) 3-6
-
(2000)
Congest. Heart Fail
, vol.6
, Issue.2
, pp. 3-6
-
-
Strobeck, J.E.1
Silver, M.2
Ventura, H.3
-
5
-
-
0037090669
-
Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy
-
Drazner M.H., Thompson B., Rosenberg P.B., Kaiser P.A., Boehrer J.D., Baldwin B.J., Dries D.L., and Yancy C.W. Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy. Am. J. Cardiol. 89 15 (2002) 993-995
-
(2002)
Am. J. Cardiol.
, vol.89
, Issue.15
, pp. 993-995
-
-
Drazner, M.H.1
Thompson, B.2
Rosenberg, P.B.3
Kaiser, P.A.4
Boehrer, J.D.5
Baldwin, B.J.6
Dries, D.L.7
Yancy, C.W.8
-
6
-
-
0034427136
-
Comparative overview of cardiac output measurement methods: has impedance cardiography come of Age?
-
De Maria A.N., and Raisinghani A. Comparative overview of cardiac output measurement methods: has impedance cardiography come of Age?. Congest. Heart Fail 6 2 (2000) 7-18
-
(2000)
Congest. Heart Fail
, vol.6
, Issue.2
, pp. 7-18
-
-
De Maria, A.N.1
Raisinghani, A.2
-
7
-
-
33746332724
-
Automated non-invasive assessment of cardiovascular function, spectral analysis and baroreceptor sensitivity for the diagnosis of syncopes, World Congress on Medical Physics and Biomedical Engineering
-
Fortin J., Gratze G., Wach P., and Skrabal F. Automated non-invasive assessment of cardiovascular function, spectral analysis and baroreceptor sensitivity for the diagnosis of syncopes, World Congress on Medical Physics and Biomedical Engineering. Med. Biol. Eng. Comput. 35 Suppl. I (1997) 466
-
(1997)
Med. Biol. Eng. Comput.
, vol.35
, Issue.SUPPL. I
, pp. 466
-
-
Fortin, J.1
Gratze, G.2
Wach, P.3
Skrabal, F.4
-
8
-
-
0344765505
-
A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume blood pressure, total peripheral resistance and for assessment of autonomic function
-
Gratze G., Fortin J., Holler A., Grasenick K., Pfurtscheller G., Wach P., Kotanko P., and Skrabal F. A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume blood pressure, total peripheral resistance and for assessment of autonomic function. Comput. Biol. Med. 28 (1998) 121-142
-
(1998)
Comput. Biol. Med.
, vol.28
, pp. 121-142
-
-
Gratze, G.1
Fortin, J.2
Holler, A.3
Grasenick, K.4
Pfurtscheller, G.5
Wach, P.6
Kotanko, P.7
Skrabal, F.8
-
9
-
-
33747847206
-
-
J. Fortin, W. Habenbacher, R. Gruellenberger, P. Wach, F. Skrabal, Real-time monitor for hemodynamic beat-to-beat parameters and power spectra analysis of the biosignals, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, vol. 20, 1998, p. 1.
-
-
-
-
10
-
-
33747828727
-
-
J. Fortin, W. Marte, R. Grüllenberger, A. Hacker, W. Habenbacher, A. Heller, Ch. Wagner, P. Wach, F. Skrabal, Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops, Comput. Biol. Med. 2005, accepted for publication.
-
-
-
-
12
-
-
39949083100
-
-
Wilhelm Maudrich, Vienna
-
Holzer W., Polzer K., Marko A., and Rheography RKG. Ein Verfahren der Kreislaufforschung und Kreislaufdiagnostik (1946), Wilhelm Maudrich, Vienna
-
(1946)
Ein Verfahren der Kreislaufforschung und Kreislaufdiagnostik
-
-
Holzer, W.1
Polzer, K.2
Marko, A.3
Rheography, RKG.4
-
13
-
-
0000402710
-
Electrical impedance plethysmography, A physical and physiologic approach to peripheral vascular study
-
Nyboer J. Electrical impedance plethysmography, A physical and physiologic approach to peripheral vascular study. Circulation 2 (1950) 811-821
-
(1950)
Circulation
, vol.2
, pp. 811-821
-
-
Nyboer, J.1
-
14
-
-
0013978742
-
Development and evaluation of an impedance cardiac output system
-
Kubicek W.G., Karnegis J.N., Patterson R.P., Witsoe D.A., and Mattson R.H. Development and evaluation of an impedance cardiac output system. Aerosp. Med. 37 (1966) 1208-1212
-
(1966)
Aerosp. Med.
, vol.37
, pp. 1208-1212
-
-
Kubicek, W.G.1
Karnegis, J.N.2
Patterson, R.P.3
Witsoe, D.A.4
Mattson, R.H.5
-
15
-
-
0016100772
-
The Minnesota impedance cardiograph-theory and applications
-
Kubicek W.G., Kottke F.J., Ramos M.U., Patterson R.P., Witsoe D.A., Labree J.W., Remole W., Layman T.E., Schoening H., and Garamela J.T. The Minnesota impedance cardiograph-theory and applications. Biomed. Eng. 9 (1974) 410-416
-
(1974)
Biomed. Eng.
, vol.9
, pp. 410-416
-
-
Kubicek, W.G.1
Kottke, F.J.2
Ramos, M.U.3
Patterson, R.P.4
Witsoe, D.A.5
Labree, J.W.6
Remole, W.7
Layman, T.E.8
Schoening, H.9
Garamela, J.T.10
-
16
-
-
0004214042
-
-
Van Gorcum, Assen, The Netherlands
-
Lamberts R., Visser K.R., and Zijlstra W.G. Impedance Cardiography (1984), Van Gorcum, Assen, The Netherlands
-
(1984)
Impedance Cardiography
-
-
Lamberts, R.1
Visser, K.R.2
Zijlstra, W.G.3
-
17
-
-
0017654085
-
Blood resistivity and its implications for the calculation of cardiac output by the thoracic electrical impedance technique
-
Mohapatra S.N., Costeloe K.L., and Hill D.W. Blood resistivity and its implications for the calculation of cardiac output by the thoracic electrical impedance technique. Intensive Care Med. 3 (1977) 63
-
(1977)
Intensive Care Med.
, vol.3
, pp. 63
-
-
Mohapatra, S.N.1
Costeloe, K.L.2
Hill, D.W.3
-
18
-
-
0019349890
-
Thoracic resistivity for stroke volume calculation in impedance cardiography
-
Quail A.W., Traugott F.M., Porges W.L., and White S.W. Thoracic resistivity for stroke volume calculation in impedance cardiography. J. Appl. Physiol. 50 (1981) 191
-
(1981)
J. Appl. Physiol.
, vol.50
, pp. 191
-
-
Quail, A.W.1
Traugott, F.M.2
Porges, W.L.3
White, S.W.4
-
19
-
-
33747849027
-
-
B.B. Sramek, Non-invasive measurement of cardiac output by means of electrical impedance, Proceedings of the 5th International Conference of Electrical Bioimpedance, Tokyo, Japan; 1981, p. 91.
-
-
-
-
20
-
-
0001952126
-
Stroke volume equation with a linear base impedance model and its accuracy, as compared to thermodilution and magnetic flow meter techniques in humans and animals
-
Zadar, Yugoslavia
-
Sramek B.B., Rose D.M., and Miyamoto A. Stroke volume equation with a linear base impedance model and its accuracy, as compared to thermodilution and magnetic flow meter techniques in humans and animals. Proceeding of the 6th International Conference of Electrical Bioimpedance (1983), Zadar, Yugoslavia 38
-
(1983)
Proceeding of the 6th International Conference of Electrical Bioimpedance
, pp. 38
-
-
Sramek, B.B.1
Rose, D.M.2
Miyamoto, A.3
-
21
-
-
0022980897
-
A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale
-
Bernstein D.B. A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale. Crit. Care Med. 14 (1986) 904-909
-
(1986)
Crit. Care Med.
, vol.14
, pp. 904-909
-
-
Bernstein, D.B.1
-
22
-
-
0022979027
-
Continuous non-invasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
-
Bernstein D.B. Continuous non-invasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Crit. Care. Med. 14 (1986) 898-901
-
(1986)
Crit. Care. Med.
, vol.14
, pp. 898-901
-
-
Bernstein, D.B.1
-
23
-
-
33747838868
-
-
National Heart, Lung and Blood Institute: Clinical Guidelines on the Identification, Evaluation, and Treatment of Overweight and Obesity in Adults, June 17 1998.
-
-
-
-
24
-
-
33747831485
-
-
WHO: Preventing and Managing the Global Epidemic of Obesity, Report of the World Health Organization Consultation of Obesity, WHO, Geneva, June 1997.
-
-
-
-
25
-
-
33747821190
-
-
R. Schmidt, G. Thews, Physiol. Menschen (1995) 547-548.
-
-
-
-
26
-
-
0024517171
-
Functional abnormalities in isolated left bundle branch block. The effect of interventricular asynchrony
-
Grines C.L., Bashore T.M., Boudoulas H., Olson S., Shafer P., and Wooley C.F. Functional abnormalities in isolated left bundle branch block. The effect of interventricular asynchrony. Circulation 79 4 (1989) 845-853
-
(1989)
Circulation
, vol.79
, Issue.4
, pp. 845-853
-
-
Grines, C.L.1
Bashore, T.M.2
Boudoulas, H.3
Olson, S.4
Shafer, P.5
Wooley, C.F.6
-
27
-
-
0031018613
-
Acute hemodynamic improvement by pacing in patients with severe congestive heart failure
-
Auricchio A., and Salo R.W. Acute hemodynamic improvement by pacing in patients with severe congestive heart failure. Pacing Clin. Electrophysiol. 20 2 Pt 1 (1997) 313-324
-
(1997)
Pacing Clin. Electrophysiol.
, vol.20
, Issue.2 PART 1
, pp. 313-324
-
-
Auricchio, A.1
Salo, R.W.2
-
28
-
-
0033564441
-
Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure, The Pacing Therapies for Congestive Heart Failure Study Group, The Guidant Congestive Heart Failure Research Group
-
Auricchio A., Stellbrink Ch., Block M., Sack S., Vogt J., Bakker P., and Klein H. Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure, The Pacing Therapies for Congestive Heart Failure Study Group, The Guidant Congestive Heart Failure Research Group. Circulation 99 23 (1999) 2993-3001
-
(1999)
Circulation
, vol.99
, Issue.23
, pp. 2993-3001
-
-
Auricchio, A.1
Stellbrink, Ch.2
Block, M.3
Sack, S.4
Vogt, J.5
Bakker, P.6
Klein, H.7
-
29
-
-
33646944864
-
Guidelines for pacemaker therapy-indications, choice of system, follow up (German)
-
Lemke B., Fischer W., and Schulten H.K. Guidelines for pacemaker therapy-indications, choice of system, follow up (German). Z. Kardiol 85 (1996) 611-628
-
(1996)
Z. Kardiol
, vol.85
, pp. 611-628
-
-
Lemke, B.1
Fischer, W.2
Schulten, H.K.3
-
30
-
-
0035409523
-
Curriculum "Practice f Cardiac Pacing" Released jointly by the Board of the German Cardiac Society (GCS) and the German Medical Association (GMA)
-
Krämer L.-I., Markewitz A., Fröhlig G., Fischer W., and Griebenow R. Curriculum "Practice f Cardiac Pacing" Released jointly by the Board of the German Cardiac Society (GCS) and the German Medical Association (GMA). Z. Kardiol. 90 (2001) 522-529
-
(2001)
Z. Kardiol.
, vol.90
, pp. 522-529
-
-
Krämer, L.-I.1
Markewitz, A.2
Fröhlig, G.3
Fischer, W.4
Griebenow, R.5
-
31
-
-
0033003166
-
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
-
Critchley L.A.H., and Critchley J.A.J.H. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J. Clin. Monit. 15 2 (1999) 85-91
-
(1999)
J. Clin. Monit.
, vol.15
, Issue.2
, pp. 85-91
-
-
Critchley, L.A.H.1
Critchley, J.A.J.H.2
|