Volumn , Issue , 2008, Pages 4464-4471

Maximizing model parameter precision by optimizing dose in 3D [ 150]H20 PET scans

Author keywords

Blood flow measurement; Dose optimization; Image variance; NEC; Positron emission tomography

Indexed keywords

BLOOD FLOW MEASUREMENT; DOSE OPTIMIZATION; DYNAMIC PET; DYNAMIC SCAN; IMAGE VARIANCE; KINETIC MODELLING; MODEL PARAMETERS; MONTE CARLO SIMULATION; NEC; PARAMETER ESTIMATE; PET SCAN; PET/CT SCANNERS; SMALL REGION; STATISTICAL NOISE; TUMOUR PERFUSION; VARIANCE IMAGES; WHOLE-BODY;

EID: 67649191687     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774273     Document Type: Conference Paper
Times cited : (1)

References (22)
  • 2
    • 44349129408 scopus 로고
    • The theory and applications of the exchange of inert gas at the lungs and tissues
    • S. S. Kety, "The theory and applications of the exchange of inert gas at the lungs and tissues," Pharmacol. Rev., vol.3, no. 1, pp. 1-41, 1951.
    • (1951) Pharmacol. Rev. , vol.3 , Issue.1 , pp. 1-41
    • Kety, S.S.1
  • 3
    • 0001609545 scopus 로고
    • Measurement of local blood flow by the exchange of an inert, diffusible substance
    • S. S. Kety. "Measurement of local blood flow by the exchange of an inert, diffusible substance," Methods Med. Res., vol.8, pp. 228-236, 1960.
    • (1960) Methods Med. Res. , vol.8 , pp. 228-236
    • Kety, S.S.1
  • 4
    • 33644828174 scopus 로고    scopus 로고
    • Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans
    • C. C. Watson, M. E. Casey, B. Bendriem, J. P. Carney, D. W. Townsend, S. Eberl, S. Meikle, and F. P. DiFilippo, "Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans," Nucl. Med., vol.46, no. 11, pp. 1825-1834, 2005. (Pubitemid 46196644)
    • (2005) Journal of Nuclear Medicine , vol.46 , Issue.11 , pp. 1825-1834
    • Watson, C.C.1    Casey, M.E.2    Bendriem, B.3    Carney, J.P.4    Townsend, D.W.5    Eberl, S.6    Meikle, S.7    DiFilippo, F.P.8
  • 6
    • 0036731951 scopus 로고    scopus 로고
    • Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET
    • C. Lartizien, C. Comtat, P. E. Kinahan, N. Ferreira, B. Bendriem, and Trebossen, "Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET," Nucl. Med., vol.43, no. 9, pp. 1268-1278, 2002. (Pubitemid 34988777)
    • (2002) Journal of Nuclear Medicine , vol.43 , Issue.9 , pp. 1268-1278
    • Lartizien, C.1    Comtat, C.2    Kinahan, P.E.3    Ferreira, N.4    Bendriem, B.5    Trebossen, R.6
  • 9
    • 0032129163 scopus 로고    scopus 로고
    • Optimization of PET activation studies based on the SNR measured in the 3-D Hoff man brain phantom
    • PII S0278006298085498
    • H.1. Li and J. R. Votaw, "Optimization of PET activation studies based on the SNR measured in the 3-D Hoffman brain phantom," IEEE Trans. Med. Imag., vol.17, no. 4, pp. 59fr-605, 1998. (Pubitemid 128747715)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.4 , pp. 596-605
    • Li, H.H.1    Votaw, J.R.2
  • 12
    • 8344228611 scopus 로고    scopus 로고
    • Count rate dependence of local signal-to-noise ratio in positron emission tomography
    • C. Watson, "Count rate dependence of local signal-to-noise ratio in positron emission tomography," IEEE Trans. Nucl. Sci., vol.51, no. 5, pp. 2670-2680, 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.5 , pp. 2670-2680
    • Watson, C.1
  • 13
    • 33644874714 scopus 로고    scopus 로고
    • Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard
    • M. Brambilla, C. Secco, M. Dominietto, Matheoud, G. Sacchetti, and E. Inglese, "Performance characteristics obtained for a new 3dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the national electrical manufacturers association NU 2-2001 standard," Nucl. Med., vol.46, no. 12, pp. 2083-2091, 2005. (Pubitemid 46657457)
    • (2005) Journal of Nuclear Medicine , vol.46 , Issue.12 , pp. 2083-2091
    • Brambilla, M.1    Secco, C.2    Dominietto, M.3    Matheoud, R.4    Sacchetti, G.5    Inglese, E.6
  • 14
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
    • S. C. Strother, M. E. Casey, and E. 1. Hoffman, "Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents counts," IEEE Trans. Nucl. Sci., vol.37. no. 2, pp. 783-788, 1990. (Pubitemid 20713969)
    • (1990) IEEE Transactions on Nuclear Science , vol.37 , Issue.1 PART 2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 16
    • 33747584180 scopus 로고    scopus 로고
    • Optimization algorithms and weighting factors for analysis of dynamic PET studies
    • DOI 10.1088/0031-9155/51/17/007, PII S0031915506155797, 007
    • M. Yaqub, R. Boellaard, M. A. Kropholler, and A. A. Lammertsma, "Optimization algorithms and weighting factors for analysis of dynamic PET studies," Phys. Med. Biol., vol.51, no. 17, pp. 4217-4232, 2006. (Pubitemid 44261841)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.17 , pp. 4217-4232
    • Yaqub, M.1    Boellaard, R.2    Kropholler, M.A.3    Lammertsma, A.A.4
  • 18
    • 0022978348 scopus 로고
    • 15O autoradiography and positron emission tomography, with respect to the dispersion of the input function
    • H. Iida, Kanno, S. Miura, M. Murakami, K. Takahashi, and K. Uemura. "Error analysis of a quantitative cerebral blood-flow measurement using H2 150 autoradiography and positron emission tomography, with respect to the dispersion of the input function," Cereb. Blood Flow Metab., vol.6, no. 5, pp. 536-545, 1986. (Pubitemid 17198737)
    • (1986) Journal of Cerebral Blood Flow and Metabolism , vol.6 , Issue.5 , pp. 536-545
    • Iida, H.1    Kanno, I.2    Miura, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.