Patient-specific noise-equivalent-counts from repeated, dose varying [O-15]H2O PET scans

Author keywords

Blood flow; Dose optimisation; Dynamic positron emission tomography; Injected dose; NEC; Noise equivalent count rate; PET; Volume of distribution, water

Indexed keywords

BLOOD; DIAGNOSTIC RADIOGRAPHY; EXTRAPOLATION; HEMODYNAMICS; MEDICAL IMAGING; PHYSIOLOGICAL MODELS; POSITRON ANNIHILATION SPECTROSCOPY; POSITRONS; SCANNING; SIGNAL TO NOISE RATIO; TOMOGRAPHY;

EID: 48349116135     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436837     Document Type: Conference Paper
Times cited : (2)

References (7)
  • 1
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalents counts
    • S. C. Strother, M. E. Casey, and E. J. Hoffman. "Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents counts," IEEE Trans. Nucl. Sci., vol. 37, no. 2, pp. 783-788, 1990.
    • (1990) IEEE Trans. Nucl. Sci , vol.37 , Issue.2 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 2
    • 8344228611 scopus 로고    scopus 로고
    • Count rate dependence of local signal-to-noise ratio in positron emission tomography
    • C. C. Watson, "Count rate dependence of local signal-to-noise ratio in positron emission tomography," IEEE Trans. Nucl. Sci., vol. 51. no. 5, pp. 2670-2680, 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , Issue.5 , pp. 2670-2680
    • Watson, C.C.1
  • 3
    • 33644828174 scopus 로고    scopus 로고
    • Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans
    • C. C. Watson. M. E. Casey, B. Bendriem. J. P. Carney, D. W. Townsend, S. Eberl, S. Meikle, and F. P. DiFilippo, "Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans," J. Nucl Med., vol. 46, no. 11, pp. 1825-1834, 2005.
    • (2005) J. Nucl Med , vol.46 , Issue.11 , pp. 1825-1834
    • Watson, C.C.1    Casey, M.E.2    Bendriem, B.3    Carney, J.P.4    Townsend, D.W.5    Eberl, S.6    Meikle, S.7    DiFilippo, F.P.8
  • 5
    • 33644874714 scopus 로고    scopus 로고
    • Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the national electrical manufacturers association NU 2-2001 standard
    • M. Brambilla. C. Secco, M. Dominietto, R. Matheoud, G. Sacchetti, and E. Inglese. "Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the national electrical manufacturers association NU 2-2001 standard." J. Nucl. Med., vol. 46. no. 12, pp. 2083-91, 2005.
    • (2005) J. Nucl. Med , vol.46 , Issue.12 , pp. 2083-2091
    • Brambilla, M.1    Secco, C.2    Dominietto, M.3    Matheoud, R.4    Sacchetti, G.5    Inglese, E.6
  • 7
    • 0003710941 scopus 로고    scopus 로고
    • National Electrical Manufacturers Association. NEMA Standards Publication NU-2
    • "Performance measurements of positron emission tomographs," National Electrical Manufacturers Association. NEMA Standards Publication NU-2 2001.
    • (2001) Performance measurements of positron emission tomographs


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.