2
-
-
0026219522
-
Noise equivalent count measurements in a neuro-PET scanner with retractable septa
-
Bailey DL, Jones T, Spinks TJ, et al. Noise equivalent count measurements in a neuro-PET scanner with retractable septa. IEEE Trans Med Imaging. 1991;10: 256-260.
-
(1991)
IEEE Trans Med Imaging
, vol.10
, pp. 256-260
-
-
Bailey, D.L.1
Jones, T.2
Spinks, T.J.3
-
3
-
-
0027644025
-
Optimization of PET instrumentation for brain activation studies
-
Dahlbom M, Cherry SR, Eriksson L, et al. Optimization of PET instrumentation for brain activation studies. IEEE Trans Nucl Sci. 1993;40:1048-1054.
-
(1993)
IEEE Trans Nucl Sci
, vol.40
, pp. 1048-1054
-
-
Dahlbom, M.1
Cherry, S.R.2
Eriksson, L.3
-
5
-
-
0029849910
-
Optimization of noise-equivalent count rates in 3D PET
-
Badawi RD, Marsden PK, Cronin BF, et al. Optimization of noise-equivalent count rates in 3D PET. Phys Med Biol. 1996;41:1755-1776.
-
(1996)
Phys Med Biol
, vol.41
, pp. 1755-1776
-
-
Badawi, R.D.1
Marsden, P.K.2
Cronin, B.F.3
-
6
-
-
0036788462
-
PET performance measurements using the NEMA NU 2-2001 standard
-
Daube-Witherspoon ME, Karp JS, Casey ME, et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med. 2002;43:1398-1409.
-
(2002)
J Nucl Med
, vol.43
, pp. 1398-1409
-
-
Daube-Witherspoon, M.E.1
Karp, J.S.2
Casey, M.E.3
-
9
-
-
0036731951
-
Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET
-
Lartizien C, Comtat C, Kinahan PE, et al. Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET. J Nucl Med. 2002;43:1268-1278.
-
(2002)
J Nucl Med
, vol.43
, pp. 1268-1278
-
-
Lartizien, C.1
Comtat, C.2
Kinahan, P.E.3
-
10
-
-
0142126679
-
Evaluation of clinical PET count rate performance
-
Watson CC, Casey ME, Beyer T, et al. Evaluation of clinical PET count rate performance. IEEE Trans Nucl Sci. 2003;50:1379-1385.
-
(2003)
IEEE Trans Nucl Sci
, vol.50
, pp. 1379-1385
-
-
Watson, C.C.1
Casey, M.E.2
Beyer, T.3
-
11
-
-
23844433096
-
Advances in scatter correction for 3D PET/CT. In
-
Piscataway, NJ: IEEE;
-
Watson CC, Casey ME, Michel C, Bendriem B. Advances in scatter correction for 3D PET/CT. In: 2004 IEEE Nuclear Science Symposium and Medical Imaging Conference [book on CD-ROM]. Piscataway, NJ: IEEE; 2004:M5-166.
-
(2004)
IEEE Nuclear Science Symposium and Medical Imaging Conference [book on CD-ROM]
, vol.2004
-
-
Watson, C.C.1
Casey, M.E.2
Michel, C.3
Bendriem, B.4
-
12
-
-
8344228611
-
Count rate dependence of local signal-to-noise ratio in positron emission tomography
-
Watson CC. Count rate dependence of local signal-to-noise ratio in positron emission tomography. IEEE Trans Nucl Sci. 2004;51:2670-2680.
-
(2004)
IEEE Trans Nucl Sci
, vol.51
, pp. 2670-2680
-
-
Watson, C.C.1
-
17
-
-
2642558094
-
PET performance measurements for an LSO based combined PET/CT scanner using the NEMA NU 2-2001 standard
-
Erdi YE, Nehmeh SA, Mulnix T, et al. PET performance measurements for an LSO based combined PET/CT scanner using the NEMA NU 2-2001 standard. J Nucl Med. 2003;45:813-821.
-
(2003)
J Nucl Med
, vol.45
, pp. 813-821
-
-
Erdi, Y.E.1
Nehmeh, S.A.2
Mulnix, T.3
-
19
-
-
11844306591
-
Performance comparison of a current LSO PET scanner versus upgraded electronics. In
-
Piscataway, NJ: IEEE;
-
Puterbaugh KC, Breeding JE, Musrock MS, Seaver CE, Young JW. Performance comparison of a current LSO PET scanner versus upgraded electronics. In: 2003 IEEE Nuclear Science Symposium and Medical Imaging Conference [book on CD-ROM]. Piscataway, NJ: IEEE; 2003:M3-133.
-
(2003)
IEEE Nuclear Science Symposium and Medical Imaging Conference [book on CD-ROM]
, vol.2003
-
-
Puterbaugh, K.C.1
Breeding, J.E.2
Musrock, M.S.3
Seaver, C.E.4
Young, J.W.5
-
22
-
-
2642561322
-
Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability
-
Halpern BS, Dahlbom M, Quon A, et al. Impact of patient weight and emission scan duration on PET/CT image quality and lesion detectability. J Nucl Med. 2004;45:797-801.
-
(2004)
J Nucl Med
, vol.45
, pp. 797-801
-
-
Halpern, B.S.1
Dahlbom, M.2
Quon, A.3
-
23
-
-
19644389147
-
Optimizing imaging protocols for overweight and obese patients: A lutetium orthosilicate PET/CT study
-
Halpern BS, Dahlbom M, Auerbach MA, et al. Optimizing imaging protocols for overweight and obese patients: a lutetium orthosilicate PET/CT study. J Nucl Med. 2005;46:603-607.
-
(2005)
J Nucl Med
, vol.46
, pp. 603-607
-
-
Halpern, B.S.1
Dahlbom, M.2
Auerbach, M.A.3
|