메뉴 건너뛰기




Volumn 46, Issue 12, 2005, Pages 2083-2091

Performance characteristics obtained for a new 3-dimensional lutetium oxyorthosilicate-based whole-body PET/CT scanner with the National Electrical Manufacturers Association NU 2-2001 standard

Author keywords

Biograph 16 HI REZ; Instrumentation; NEMA standard; PET CT; Quality assurance

Indexed keywords

LUTETIUM OXYORTHOSILICATE; TRACER; UNCLASSIFIED DRUG; LUTETIUM; SILICATE;

EID: 33644874714     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (127)

References (7)
  • 2
    • 2642558094 scopus 로고    scopus 로고
    • PET performance measurements for an LSO-based combined PET/CT scanner using the National Electrical Manufacturers Association NU 2-2001 standard
    • Erdi YE, Nehmen SA, Mulnix T, Humm JL, Watson CC. PET performance measurements for an LSO-based combined PET/CT scanner using the National Electrical Manufacturers Association NU 2-2001 standard. J Nucl Med. 2004;45:813-821.
    • (2004) J Nucl Med , vol.45 , pp. 813-821
    • Erdi, Y.E.1    Nehmen, S.A.2    Mulnix, T.3    Humm, J.L.4    Watson, C.C.5
  • 3
    • 2942584985 scopus 로고    scopus 로고
    • Performance evaluation of the new whole-body PET/CT scanner: Discovery ST
    • Bettinardi V, Danna M, Savi A, et al. Performance evaluation of the new whole-body PET/CT scanner: Discovery ST. Eur J Nucl Med Mol Imaging. 2004;31:867-881.
    • (2004) Eur J Nucl Med Mol Imaging , vol.31 , pp. 867-881
    • Bettinardi, V.1    Danna, M.2    Savi, A.3
  • 4
    • 3242717954 scopus 로고    scopus 로고
    • Imaging characteristics of a 3-dimensional GSO whole-body PET camera
    • Surti S, Karp JS. Imaging characteristics of a 3-dimensional GSO whole-body PET camera. J Nucl Med. 2004;45:1040-1049.
    • (2004) J Nucl Med , vol.45 , pp. 1040-1049
    • Surti, S.1    Karp, J.S.2
  • 5
    • 16544364015 scopus 로고    scopus 로고
    • Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes
    • Mawlawi O, Podoloff DA, Kohlmyer S, et al. Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. J Nucl Med. 2004;45:1734-1742.
    • (2004) J Nucl Med , vol.45 , pp. 1734-1742
    • Mawlawi, O.1    Podoloff, D.A.2    Kohlmyer, S.3
  • 7
    • 1142287528 scopus 로고    scopus 로고
    • The use of molecular sieves to produce point sources of radioactivity
    • Bailey DL, Snowdon G, Cooper RG, Roach PJ. The use of molecular sieves to produce point sources of radioactivity. Phys Med Biol. 2004;49:N21-N29.
    • (2004) Phys Med Biol , vol.49
    • Bailey, D.L.1    Snowdon, G.2    Cooper, R.G.3    Roach, P.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.