메뉴 건너뛰기




Volumn 18, Issue 4, 2009, Pages 515-520

Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: A prospective-randomized clinical study

Author keywords

computer assisted surgery; computer tomography; glenoid version; Total shoulder arthroplasty

Indexed keywords

ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FOLLOW UP; HUMAN; OPERATION DURATION; OSTEOARTHRITIS; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; SHOULDER; SHOULDER ARTHROPLASTY; VALIDITY;

EID: 67449119189     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2009.03.014     Document Type: Article
Times cited : (141)

References (33)
  • 1
    • 33847131055 scopus 로고    scopus 로고
    • Computer aided surgery system for shoulder prosthesis placement
    • Atmani H., Merienne F., Fofi D., and Trouilloud P. Computer aided surgery system for shoulder prosthesis placement. Comput Aided Surg 12 (2007) 60-70
    • (2007) Comput Aided Surg , vol.12 , pp. 60-70
    • Atmani, H.1    Merienne, F.2    Fofi, D.3    Trouilloud, P.4
  • 3
    • 34247574623 scopus 로고    scopus 로고
    • Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods
    • Bicknell R.T., DeLude J.A., Kedgley A.E., Ferreira L.M., Dunning C.E., King G.J., et al. Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. J Shoulder Elbow Surg 16 (2007) S117-S125
    • (2007) J Shoulder Elbow Surg , vol.16
    • Bicknell, R.T.1    DeLude, J.A.2    Kedgley, A.E.3    Ferreira, L.M.4    Dunning, C.E.5    King, G.J.6
  • 4
    • 0033218441 scopus 로고    scopus 로고
    • Variability of measurement of glenoid version on computed tomography scan
    • Bokor D.J., O'Sullivan M.D., and Hazan G.J. Variability of measurement of glenoid version on computed tomography scan. J Shoulder Elbow Surg 8 (1999) 595-598
    • (1999) J Shoulder Elbow Surg , vol.8 , pp. 595-598
    • Bokor, D.J.1    O'Sullivan, M.D.2    Hazan, G.J.3
  • 5
    • 41849120826 scopus 로고    scopus 로고
    • Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty
    • Catani F., Biasca N., Ensini A., Leardini A., Bianchi L., Digennaro V., et al. Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty. J Bone Joint Surg Am 90 (2008) 765-771
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 765-771
    • Catani, F.1    Biasca, N.2    Ensini, A.3    Leardini, A.4    Bianchi, L.5    Digennaro, V.6
  • 6
    • 0035407670 scopus 로고    scopus 로고
    • Glenoid size, inclination, and version: an anatomic study
    • Churchill R.S., Brems J.J., and Kotschi H. Glenoid size, inclination, and version: an anatomic study. J Shoulder Elbow Surg 10 (2001) 327-332
    • (2001) J Shoulder Elbow Surg , vol.10 , pp. 327-332
    • Churchill, R.S.1    Brems, J.J.2    Kotschi, H.3
  • 9
    • 33745736595 scopus 로고    scopus 로고
    • Risks of loosening of a prosthetic glenoid implanted in retroversion
    • Farron A., Terrier A., and Buchler P. Risks of loosening of a prosthetic glenoid implanted in retroversion. J Shoulder Elbow Surg 15 (2006) 521-526
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 521-526
    • Farron, A.1    Terrier, A.2    Buchler, P.3
  • 10
    • 0026786765 scopus 로고
    • The use of computerized tomography in the measurement of glenoid version
    • Friedman R.J., Hawthorne K.B., and Genez B.M. The use of computerized tomography in the measurement of glenoid version. J Bone Joint Surg Am 74 (1992) 1032-1037
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 1032-1037
    • Friedman, R.J.1    Hawthorne, K.B.2    Genez, B.M.3
  • 11
    • 33744822731 scopus 로고    scopus 로고
    • Three-dimensional glenoid deformity in patients with osteoarthritis: a radiographic analysis
    • Habermeyer P., Magosch P., Luz V., and Lichtenberg S. Three-dimensional glenoid deformity in patients with osteoarthritis: a radiographic analysis. J Bone Joint Surg Am 88 (2006) 1301-1307
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 1301-1307
    • Habermeyer, P.1    Magosch, P.2    Luz, V.3    Lichtenberg, S.4
  • 12
    • 46049089095 scopus 로고    scopus 로고
    • Optimizing glenoid component position using three-dimensional computed tomography reconstruction
    • Hoenecke Jr. H.R., Hermida J.C., Dembitsky N., Patil S., and D'Lima D.D. Optimizing glenoid component position using three-dimensional computed tomography reconstruction. J Shoulder Elbow Surg 17 (2008) 637-641
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 637-641
    • Hoenecke Jr., H.R.1    Hermida, J.C.2    Dembitsky, N.3    Patil, S.4    D'Lima, D.D.5
  • 13
    • 9644262410 scopus 로고    scopus 로고
    • The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty
    • Hopkins A.R., Hansen U.N., Amis A.A., and Emery R. The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty. J Shoulder Elbow Surg 13 (2004) 668-675
    • (2004) J Shoulder Elbow Surg , vol.13 , pp. 668-675
    • Hopkins, A.R.1    Hansen, U.N.2    Amis, A.A.3    Emery, R.4
  • 14
    • 33846076965 scopus 로고    scopus 로고
    • Glenohumeral kinematics following total shoulder arthroplasty: a finite element investigation
    • Hopkins A.R., Hansen U.N., Amis A.A., Taylor M., and Emery R.J. Glenohumeral kinematics following total shoulder arthroplasty: a finite element investigation. J Orthop Res 25 (2007) 108-115
    • (2007) J Orthop Res , vol.25 , pp. 108-115
    • Hopkins, A.R.1    Hansen, U.N.2    Amis, A.A.3    Taylor, M.4    Emery, R.J.5
  • 15
    • 0037315792 scopus 로고    scopus 로고
    • Influence of preoperative factors on outcome of shoulder arthroplasty for glenohumeral osteoarthritis
    • Iannotti J.P., and Norris T.R. Influence of preoperative factors on outcome of shoulder arthroplasty for glenohumeral osteoarthritis. J Bone Joint Surg Am 85 (2003) 251-258
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 251-258
    • Iannotti, J.P.1    Norris, T.R.2
  • 17
    • 34250666688 scopus 로고    scopus 로고
    • The glenoid center point: a magnetic resonance imaging study of normal scapular anatomy
    • Meyer N.J., Pennington W.T., and Ziegler D.W. The glenoid center point: a magnetic resonance imaging study of normal scapular anatomy. Am J Orthop 36 (2007) 200-202
    • (2007) Am J Orthop , vol.36 , pp. 200-202
    • Meyer, N.J.1    Pennington, W.T.2    Ziegler, D.W.3
  • 19
    • 34249882726 scopus 로고    scopus 로고
    • Design and development of a computer assisted glenoid implantation technique for shoulder replacement surgery
    • Nguyen D., Ferreira L.M., Brownhill J.R., Faber K.J., and Johnson J.A. Design and development of a computer assisted glenoid implantation technique for shoulder replacement surgery. Comput Aided Surg 12 (2007) 152-159
    • (2007) Comput Aided Surg , vol.12 , pp. 152-159
    • Nguyen, D.1    Ferreira, L.M.2    Brownhill, J.R.3    Faber, K.J.4    Johnson, J.A.5
  • 20
    • 0042849347 scopus 로고    scopus 로고
    • Functional outcome after shoulder arthroplasty for primary osteoarthritis: a multicenter study
    • Norris T.R., and Iannotti J.P. Functional outcome after shoulder arthroplasty for primary osteoarthritis: a multicenter study. J Shoulder Elbow Surg 11 (2002) 130-135
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 130-135
    • Norris, T.R.1    Iannotti, J.P.2
  • 21
    • 0141892870 scopus 로고    scopus 로고
    • Measurement of glenoid version: conventional radiographs versus computed tomography scans
    • Nyffeler R.W., Jost B., Pfirrmann C.W., and Gerber C. Measurement of glenoid version: conventional radiographs versus computed tomography scans. J Shoulder Elbow Surg 12 (2003) 493-496
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 493-496
    • Nyffeler, R.W.1    Jost, B.2    Pfirrmann, C.W.3    Gerber, C.4
  • 22
    • 33748438366 scopus 로고    scopus 로고
    • Effects of glenoid component version on humeral head displacement and joint reaction forces: an experimental study
    • Nyffeler R.W., Sheikh R., Atkinson T.S., Jacob H.A., Favre P., and Gerber C. Effects of glenoid component version on humeral head displacement and joint reaction forces: an experimental study. J Shoulder Elbow Surg 15 (2006) 625-629
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 625-629
    • Nyffeler, R.W.1    Sheikh, R.2    Atkinson, T.S.3    Jacob, H.A.4    Favre, P.5    Gerber, C.6
  • 23
    • 25444490893 scopus 로고    scopus 로고
    • Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis
    • Nyffeler R.W., Werner C.M., and Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg 14 (2005) 524-528
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 524-528
    • Nyffeler, R.W.1    Werner, C.M.2    Gerber, C.3
  • 24
    • 8644282919 scopus 로고    scopus 로고
    • Effect of glenoid component inclination on its fixation and humeral head subluxation in total shoulder arthroplasty
    • Oosterom R., Rozing P.M., and Bersee H.E. Effect of glenoid component inclination on its fixation and humeral head subluxation in total shoulder arthroplasty. Clin Biomech (Bristol, Avon) 19 (2004) 1000-1008
    • (2004) Clin Biomech (Bristol, Avon) , vol.19 , pp. 1000-1008
    • Oosterom, R.1    Rozing, P.M.2    Bersee, H.E.3
  • 25
    • 0022465759 scopus 로고
    • Glenohumeral osteometry by computed tomography in normal and unstable shoulders
    • Randelli M., and Gambrioli P.L. Glenohumeral osteometry by computed tomography in normal and unstable shoulders. Clin Orthop Relat Res (1986) 151-156
    • (1986) Clin Orthop Relat Res , pp. 151-156
    • Randelli, M.1    Gambrioli, P.L.2
  • 26
    • 42749093373 scopus 로고    scopus 로고
    • The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritis
    • Scalise J.J., Codsi M.J., Bryan J., and Iannotti J.P. The three-dimensional glenoid vault model can estimate normal glenoid version in osteoarthritis. J Shoulder Elbow Surg 17 (2008) 487-491
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 487-491
    • Scalise, J.J.1    Codsi, M.J.2    Bryan, J.3    Iannotti, J.P.4
  • 29
    • 16844379953 scopus 로고    scopus 로고
    • The effect of humeral component anteversion on shoulder stability with glenoid component retroversion
    • Spencer Jr. E.E., Valdevit A., Kambic H., Brems J.J., and Iannotti J.P. The effect of humeral component anteversion on shoulder stability with glenoid component retroversion. J Bone Joint Surg Am 87 (2005) 808-814
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 808-814
    • Spencer Jr., E.E.1    Valdevit, A.2    Kambic, H.3    Brems, J.J.4    Iannotti, J.P.5
  • 32
    • 0032859420 scopus 로고    scopus 로고
    • Morphologic study of the glenoid in primary glenohumeral osteoarthritis
    • Walch G., Badet R., Boulahia A., and Khoury A. Morphologic study of the glenoid in primary glenohumeral osteoarthritis. J Arthroplasty 14 (1999) 756-760
    • (1999) J Arthroplasty , vol.14 , pp. 756-760
    • Walch, G.1    Badet, R.2    Boulahia, A.3    Khoury, A.4
  • 33
    • 16644386289 scopus 로고    scopus 로고
    • CT-based preoperative analysis of scapula morphology and glenohumeral joint geometry
    • Welsch G., Mamisch T.C., Kikinis R., et al. CT-based preoperative analysis of scapula morphology and glenohumeral joint geometry. Comput Aided Surg 8 (2003) 264-268
    • (2003) Comput Aided Surg , vol.8 , pp. 264-268
    • Welsch, G.1    Mamisch, T.C.2    Kikinis, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.