메뉴 건너뛰기




Volumn 29, Issue 5, 2009, Pages 1147-1153

Improved Vessel Delineation in Keyhole Time- Resolved Contrast-Enhanced MR Angiography Using a Gadolinium Doped Flush

Author keywords

Carotid artery; Cerebral vessels; Cineangiography; Gadolinium; Gadoterate; Internal; Magnetic resonance angiography

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM; GADOTERATE MEGLUMINE; GADOTERIC ACID; SODIUM CHLORIDE; GADOLINIUM 1,4,7,10-TETRAAZACYCLODODECANE-N,N',N'',N'''-TETRAACETATE; HETEROCYCLIC COMPOUND; ORGANOMETALLIC COMPOUND;

EID: 66149105147     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21761     Document Type: Article
Times cited : (9)

References (20)
  • 1
    • 10744232941 scopus 로고    scopus 로고
    • Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: A prospective, multi-centre blinded comparison with digital subtraction angiography
    • Hentsch A, Aschauer MA, Balzer JO, et al. Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography. Eur Radiol 2003;13: 2103-2114.
    • (2003) Eur Radiol , vol.13 , pp. 2103-2114
    • Hentsch, A.1    Aschauer, M.A.2    Balzer, J.O.3
  • 2
    • 11144238401 scopus 로고    scopus 로고
    • Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: A prospective, intra-individual comparative analysis with digital subtraction angiography
    • Willinek WA, von Falkenhausen M, Born M, et al. Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography. Stroke 2005;36:38-43.
    • (2005) Stroke , vol.36 , pp. 38-43
    • Willinek, W.A.1    von Falkenhausen, M.2    Born, M.3
  • 3
    • 33845904906 scopus 로고    scopus 로고
    • Ultrafast time-resolved contrast-enhanced 3D pulmonary venous cardiovascular magnetic resonance angiography using SENSE combined with CENTRA-keyhole
    • Korperich H, Gieseke J, Esdorn H, et al. Ultrafast time-resolved contrast-enhanced 3D pulmonary venous cardiovascular magnetic resonance angiography using SENSE combined with CENTRA-keyhole. J Cardiovasc Magn Reson 2007;9:77-87.
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 77-87
    • Korperich, H.1    Gieseke, J.2    Esdorn, H.3
  • 4
    • 0027633059 scopus 로고
    • Keyhole method for accelerating imaging of contrast agent uptake
    • van Vaals JJ, Brummer ME, Dixon WT, et al. "Keyhole" method for accelerating imaging of contrast agent uptake. J Magn Reson Imaging 1993;3:671-675.
    • (1993) J Magn Reson Imaging , vol.3 , pp. 671-675
    • van Vaals, J.J.1    Brummer, M.E.2    Dixon, W.T.3
  • 5
    • 10644244513 scopus 로고    scopus 로고
    • Highresolution time-resolved contrast-enhanced 3D MRA by combining SENSE with keyhole and SLAM strategies
    • Wu Y, Goodrich KC, Buswell HR, Katzman GL, Parker DL. Highresolution time-resolved contrast-enhanced 3D MRA by combining SENSE with keyhole and SLAM strategies. Magn Reson Imaging 2004;22:1161-1168.
    • (2004) Magn Reson Imaging , vol.22 , pp. 1161-1168
    • Wu, Y.1    Goodrich, K.C.2    Buswell, H.R.3    Katzman, G.L.4    Parker, D.L.5
  • 6
    • 0036829410 scopus 로고    scopus 로고
    • Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: Initial experience
    • Willinek WA, Gieseke J, Conrad R, et al. Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology 2002;225:583-588.
    • (2002) Radiology , vol.225 , pp. 583-588
    • Willinek, W.A.1    Gieseke, J.2    Conrad, R.3
  • 7
    • 34047100331 scopus 로고    scopus 로고
    • Time-resolved, high-resolution contrast-enhanced MR angiography of dialysis shunts using the CENTRA keyhole technique with parallel imaging
    • Mende KA, Froehlich JM, von Weymarn C, et al. Time-resolved, high-resolution contrast-enhanced MR angiography of dialysis shunts using the CENTRA keyhole technique with parallel imaging. J Magn Reson Imaging 2007;25:832-840.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 832-840
    • Mende, K.A.1    Froehlich, J.M.2    von Weymarn, C.3
  • 8
    • 44449098200 scopus 로고    scopus 로고
    • 4D timeresolved MR angiography with keyhole (4D-TRAK) : More than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0T
    • Willinek WA, Hadizadeh DR, von Falkenhausen M, et al. 4D timeresolved MR angiography with keyhole (4D-TRAK) : more than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0T. J Magn Reson Imaging 2008;27:1455-1460.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1455-1460
    • Willinek, W.A.1    Hadizadeh, D.R.2    von Falkenhausen, M.3
  • 9
    • 37348998523 scopus 로고    scopus 로고
    • Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA
    • Hadizadeh DR von Falkenhausen M, Gieseke J, et al. Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA. Radiology 2008;246:205-213.
    • (2008) Radiology , vol.246 , pp. 205-213
    • Hadizadeh, D.R.1    von Falkenhausen, M.2    Gieseke, J.3
  • 10
    • 35148883787 scopus 로고    scopus 로고
    • Gamma knife surgery for arteriovenous malformations in the brain: Integration of time-resolved contrast-enhanced magnetic resonance angiography into dosimetry planning. Technical note
    • Taschner CA, Le Thuc V, Reyns N, et al. Gamma knife surgery for arteriovenous malformations in the brain: integration of time-resolved contrast-enhanced magnetic resonance angiography into dosimetry planning. Technical note. J Neurosurg 2007;107:854-859.
    • (2007) J Neurosurg , vol.107 , pp. 854-859
    • Taschner, C.A.1    Le Thuc, V.2    Reyns, N.3
  • 11
    • 24144445451 scopus 로고    scopus 로고
    • Dose optimization of contrast-enhanced carotid MR angiography
    • Unterweger M, Froehlich JM, Kubik-Huch RA, et al. Dose optimization of contrast-enhanced carotid MR angiography. Eur Radiol 2005;15:1797-1805.
    • (2005) Eur Radiol , vol.15 , pp. 1797-1805
    • Unterweger, M.1    Froehlich, J.M.2    Kubik-Huch, R.A.3
  • 12
    • 45149118018 scopus 로고    scopus 로고
    • Direct MR arthrography at 1.5 and 3.0T: Signal dependence on gadolinium and iodine concentrations - phantom study
    • Andreisek G, Froehlich JM, Hodler J, et al. Direct MR arthrography at 1.5 and 3.0T: signal dependence on gadolinium and iodine concentrations - phantom study. Radiology 2008;247:706-716.
    • (2008) Radiology , vol.247 , pp. 706-716
    • Andreisek, G.1    Froehlich, J.M.2    Hodler, J.3
  • 14
    • 34247854907 scopus 로고    scopus 로고
    • Time-resolved contrast-enhanced carotid imaging using undersampled projection reconstruction acquisition
    • Du J, Fain SB, Korosec FR, Grist TM, Mistretta CA. Time-resolved contrast-enhanced carotid imaging using undersampled projection reconstruction acquisition. J Magn Reson Imaging 2007;25:1093-1099.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 1093-1099
    • Du, J.1    Fain, S.B.2    Korosec, F.R.3    Grist, T.M.4    Mistretta, C.A.5
  • 15
    • 33646684312 scopus 로고    scopus 로고
    • Time-resolved 3D contrastenhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: Initial experience
    • Meckel S, Mekle R, Taschner C, et al. Time-resolved 3D contrastenhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience. Neuroradiology 2006;48:291-299.
    • (2006) Neuroradiology , vol.48 , pp. 291-299
    • Meckel, S.1    Mekle, R.2    Taschner, C.3
  • 16
    • 4644262669 scopus 로고    scopus 로고
    • High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction
    • Zhu H, Buck DG, Zhang Z, et al. High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction. Magn Reson Med 2004;52:14-18.
    • (2004) Magn Reson Med , vol.52 , pp. 14-18
    • Zhu, H.1    Buck, D.G.2    Zhang, Z.3
  • 17
    • 0035084669 scopus 로고    scopus 로고
    • Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes
    • Boos M, Scheffler K, Haselhorst R, Reese E, Frohlich J, Bongartz GM. Arterial first pass gadolinium-CM dynamics as a function of several intravenous saline flush and Gd volumes. J Magn Reson Imaging 2001;13:568-576.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 568-576
    • Boos, M.1    Scheffler, K.2    Haselhorst, R.3    Reese, E.4    Frohlich, J.5    Bongartz, G.M.6
  • 18
    • 41949089144 scopus 로고    scopus 로고
    • Time-resolved contrastenhanced MR angiography of intracranial lesions
    • Zou Z, Ma L, Cheng L, Cai Y, Meng X. Time-resolved contrastenhanced MR angiography of intracranial lesions. J Magn Reson Imaging 2008;27:692-699.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 692-699
    • Zou, Z.1    Ma, L.2    Cheng, L.3    Cai, Y.4    Meng, X.5
  • 19
    • 4444225987 scopus 로고    scopus 로고
    • Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: Initial experience
    • Tsuchiya K, Aoki C, Fujikawa A, Hachiya J. Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience. Eur Radiol 2004;14:1494-1497.
    • (2004) Eur Radiol , vol.14 , pp. 1494-1497
    • Tsuchiya, K.1    Aoki, C.2    Fujikawa, A.3    Hachiya, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.