The Leksell Gamma Knife Perfexion and comparisons with its predecessors
-
0148-396X,. 10.1227/01.neu.0000289726.35330.8a
-
C. Lindquist and I. Paddick, " The Leksell Gamma Knife Perfexion and comparisons with its predecessors.," Neurosurgery 0148-396X 61, 130-140 (2007). 10.1227/01.neu.0000289726.35330.8a
-
(2007)
Neurosurgery
, vol.61
, pp. 130-140
-
-
Lindquist, C.1
Paddick, I.2
-
2
-
-
58949088401
-
Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C
-
0022-3085.
-
J. Novotny, Jr., J. P. Bhatnagar, A. Niranjan, M. A. Quader, M. S. Huq, G. Bednarz, J. C. Flickinger, D. S. Kondziolka, and L. D. Lunsford, " Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C.," J. Neurosurg. 0022-3085 109, 8-14 (2008).
-
(2008)
J. Neurosurg.
, vol.109
, pp. 8-14
-
-
Novotny Jr., J.1
Bhatnagar, J.P.2
Niranjan, A.3
Quader, M.A.4
Huq, M.S.5
Bednarz, G.6
Flickinger, J.C.7
Kondziolka, D.S.8
Lunsford, L.D.9
-
3
-
-
66149084837
-
Efficiency and dose-planning comparisons between the Perfexion and 4C Leksell Gamma Knife units
-
1011-6125 (to be published).
-
A. Niranjan, J. Novotny Jr., J. P. Bhatnagar, D. S. Kondziolka, and L. D. Lunsford, " Efficiency and dose-planning comparisons between the Perfexion and 4C Leksell Gamma Knife units.," Stereotact. Funct. Neurosurg. 1011-6125 (to be published).
-
Stereotact. Funct. Neurosurg.
-
-
Niranjan, A.1
Novotny Jr., J.2
Bhatnagar, J.P.3
Kondziolka, D.S.4
Lunsford, L.D.5
-
4
-
-
0025312455
-
Physics of Gamma Knife approach on convergent beams in stereotactic radiosurgery
-
0360-3016.
-
A. Wu, G. Lindner, A. H. Maitz, A. M. Kalend, L. D. Lunsford, and J. C. Flickinger, " Physics of Gamma Knife approach on convergent beams in stereotactic radiosurgery.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 18, 941-949 (1990).
-
(1990)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.18
, pp. 941-949
-
-
Wu, A.1
Lindner, G.2
Maitz, A.H.3
Kalend, A.M.4
Lunsford, L.D.5
Flickinger, J.C.6
-
5
-
-
0024492354
-
Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source gamma knife
-
0148-396X,. 10.1097/00006123-198902000-00001
-
L. D. Lunsford, J. Flickinger, G. Lindner, and A. Maitz, " Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source gamma knife.," Neurosurgery 0148-396X 24, 151-159 (1989). 10.1097/00006123-198902000-00001
-
(1989)
Neurosurgery
, vol.24
, pp. 151-159
-
-
Lunsford, L.D.1
Flickinger, J.2
Lindner, G.3
Maitz, A.4
-
6
-
-
0034433343
-
First clinical experience with the automatic positioning system and Leksell gamma knife model C, Technical note
-
0022-3085.
-
G. A. Horstmann, H. Schöpgens, A. T. C. J. Van Eck, H. J. Kreiner, and W. Hertz, " First clinical experience with the automatic positioning system and Leksell gamma knife model C, Technical note.," J. Neurosurg. 0022-3085 93, 193-197 (2000).
-
(2000)
J. Neurosurg.
, vol.93
, pp. 193-197
-
-
Horstmann, G.A.1
Schöpgens, H.2
Van Eck, A.T.C.J.3
Kreiner, H.J.4
Hertz, W.5
-
7
-
-
0036484633
-
An evaluation of the Model C gamma knife with automatic patient positioning
-
0148-396X,. 10.1097/00006123-200202000-00041
-
D. Kondziolka, A. H. Maitz, A. Niranjan, J. C. Flickinger, and L. D. Lunsford, " An evaluation of the Model C gamma knife with automatic patient positioning.," Neurosurgery 0148-396X 50, 429-431 (2002). 10.1097/00006123-200202000-00041
-
(2002)
Neurosurgery
, vol.50
, pp. 429-431
-
-
Kondziolka, D.1
Maitz, A.H.2
Niranjan, A.3
Flickinger, J.C.4
Lunsford, L.D.5
-
8
-
-
3042819108
-
The Leksell gamma knife Model U versus Model C: A quantitative comparison of radiosurgical treatment parameters
-
0148-396X,. 10.1227/01.NEU.0000126880.33125.E6
-
J. S. Kuo, C. Yu, S. L. Giannotta, Z. Petrovich, and M. L. Apuzzo, " The Leksell gamma knife Model U versus Model C: A quantitative comparison of radiosurgical treatment parameters.," Neurosurgery 0148-396X 55, 168-172 (2004). 10.1227/01.NEU.0000126880.33125.E6
-
(2004)
Neurosurgery
, vol.55
, pp. 168-172
-
-
Kuo, J.S.1
Yu, C.2
Giannotta, S.L.3
Petrovich, Z.4
Apuzzo, M.L.5
-
9
-
-
13744258554
-
A comparison of the gamma knife model C and the automatic positioning system with Leksell model B
-
0022-3085.
-
D. Tlachacova, M. Schmitt, J. Novotny, Jr., J. Novotny, M. Majali, and R. Liscak, " A comparison of the gamma knife model C and the automatic positioning system with Leksell model B.," J. Neurosurg. 0022-3085 102, 25-28 (2005).
-
(2005)
J. Neurosurg.
, vol.102
, pp. 25-28
-
-
Tlachacova, D.1
Schmitt, M.2
Novotny Jr., J.3
Novotny, J.4
Majali, M.5
Liscak, R.6
-
10
-
-
85027239742
-
-
Leksell Gamma Plan 8.2 Online Reference Manual, ELEKTA Instruments AB, Stockholm, Sweden, Document No. 1005472, Rev.01.
-
Leksell Gamma Plan 8.2 Online Reference Manual, ELEKTA Instruments AB, Stockholm, Sweden, Document No. 1005472, Rev.01, 2007.
-
(2007)
-
-
-
11
-
-
0037152478
-
Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams
-
0031-9155 10.1088/0031-9155/47/20/306.
-
G. Bednarz, M. S. Huq, and U. Rosenow, " Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/47/20/306 47, 3643-3649 (2002).
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 3643-3649
-
-
Bednarz, G.1
Huq, M.S.2
Rosenow, U.3
-
12
-
-
0036732644
-
Precision dosimetry for narrow photon beams used in radiosurgery- Determination of Gamma Knife output factors
-
0094-2405 10.1118/1.1501138.
-
A. Mack, S. Scheib, J. Major, S. Gianolini, G. Pazmandi, H. Feist, H. Czempiel, and H. J. Kreiner, " Precision dosimetry for narrow photon beams used in radiosurgery-Determination of Gamma Knife output factors.," Med. Phys. 0094-2405 10.1118/1.1501138 29, 2080-2089 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 2080-2089
-
-
MacK, A.1
Scheib, S.2
Major, J.3
Gianolini, S.4
Pazmandi, G.5
Feist, H.6
Czempiel, H.7
Kreiner, H.J.8
-
13
-
-
0038247942
-
Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors
-
0094-2405 10.1118/1.1567736.
-
J. Tsai, M. J. Rivard, M. J. Engler, J. E. Mignano, D. E. Wazer, and W. A. Schucart, " Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors.," Med. Phys. 0094-2405 10.1118/1.1567736 30, 986-992 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 986-992
-
-
Tsai, J.1
Rivard, M.J.2
Engler, M.J.3
Mignano, J.E.4
Wazer, D.E.5
Schucart, W.A.6
-
14
-
-
0041387395
-
Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector
-
0094-2405 10.1118/1.1587451.
-
F. Araki, T. Ikegami, I. Ishidoya, and H. D. Kubo, " Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector.," Med. Phys. 0094-2405 10.1118/1.1587451 30, 1976-1981 (2003).
-
(2003)
Med. Phys.
, vol.30
, pp. 1976-1981
-
-
Araki, F.1
Ikegami, T.2
Ishidoya, I.3
Kubo, H.D.4
-
15
-
-
33847655528
-
Measurement of Gamma Knife helmet factors using MOSFETs
-
0094-2405 10.1118/1.2437282.
-
L. Kurjewicz and A. Berndt, " Measurement of Gamma Knife helmet factors using MOSFETs.," Med. Phys. 0094-2405 10.1118/1.2437282 34, 1007-1012 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 1007-1012
-
-
Kurjewicz, L.1
Berndt, A.2
-
16
-
-
0032762524
-
Monte Carlo calculated output factors of a Leksell Gamma Knife unit
-
0031-9155,. 10.1088/0031-9155/44/12/401
-
J. Y. C. Cheung, K. N. Yu, C. P. Yu, and R. T. K. Ho, " Monte Carlo calculated output factors of a Leksell Gamma Knife unit.," Phys. Med. Biol. 0031-9155 44, N247-N249 (1999). 10.1088/0031-9155/44/12/401
-
(1999)
Phys. Med. Biol.
, vol.44
-
-
Cheung, J.Y.C.1
Yu, K.N.2
Yu, C.P.3
Ho, R.T.K.4
-
17
-
-
0037150458
-
Monte Carlo simulation of the Leksell GammaKnife: I. Source modeling and calculation in homogeneous media
-
0031-9155 10.1088/0031-9155/47/12/301.
-
V. Moskvin, C. DesRosiers, L. Papiez, R. Timmerman, M. Randall, and P. DesRosiers, " Monte Carlo simulation of the Leksell GammaKnife: I. Source modeling and calculation in homogeneous media.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/47/12/301 47, 1995-2011 (2002).
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 1995-2011
-
-
Moskvin, V.1
Desrosiers, C.2
Papiez, L.3
Timmerman, R.4
Randall, M.5
Desrosiers, P.6
-
18
-
-
33845920500
-
MCNP-based computational model for the Leksell Gamma Knife
-
0094-2405 10.1118/1.2401054.
-
J. Trnka, J. Novotny, Jr., and J. Kluson, " MCNP-based computational model for the Leksell Gamma Knife.," Med. Phys. 0094-2405 10.1118/1.2401054 34, 63-75 (2007).
-
(2007)
Med. Phys.
, vol.34
, pp. 63-75
-
-
Trnka, J.1
Novotny Jr., J.2
Kluson, J.3
-
19
-
-
0008796868
-
Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine
-
0094-2405 10.1118/1.598407.
-
A. Niroomand-Rad, " Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine.," Med. Phys. 0094-2405 10.1118/1.598407 25, 2093-2115 (1998).
-
(1998)
Med. Phys.
, vol.25
, pp. 2093-2115
-
-
Niroomand-Rad, A.1
-
20
-
-
0029909070
-
High-resolution dosimetry using radiochromic film and a document scanner
-
0031-9155 10.1088/0031-9155/41/11/008.
-
M. A. Stevens, J. R. Turner, R. P. Hugtenburg, and P. H. Butler, " High-resolution dosimetry using radiochromic film and a document scanner.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/41/11/008 41, 2357-2365 (1996).
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 2357-2365
-
-
Stevens, M.A.1
Turner, J.R.2
Hugtenburg, R.P.3
Butler, P.H.4
-
21
-
-
0034037793
-
Quality assurance for an image-guided frameless radiosurgery system using radiochromic film
-
0288-2043.
-
H. Shiomi, T. Inoue, and S. Nakamura, " Quality assurance for an image-guided frameless radiosurgery system using radiochromic film.," Radiat. Med. 0288-2043 18, 107-113 (2000).
-
(2000)
Radiat. Med.
, vol.18
, pp. 107-113
-
-
Shiomi, H.1
Inoue, T.2
Nakamura, S.3
-
22
-
-
0033010557
-
Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors
-
0031-9155 10.1088/0031-9155/44/4/006.
-
A. Somigliana, " Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/44/4/006 44, 887-897 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 887-897
-
-
Somigliana, A.1
-
23
-
-
2442701589
-
GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy
-
0094-2405 10.1118/1.1712393.
-
M. Yamauchi, T. Tominaga, O. Nakamura, R. Ueda, and M. Hoshi, " GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy.," Med. Phys. 0094-2405 10.1118/1.1712393 31, 1243-1248 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 1243-1248
-
-
Yamauchi, M.1
Tominaga, T.2
Nakamura, O.3
Ueda, R.4
Hoshi, M.5
-
24
-
-
0000274968
-
Verification of dose plans using film dosimetry for quality assurance in radiosurgery
-
10.1159/000062344
-
A. Mack, G. Mack, D. Weltz, H. Czempiel, and H. J. Kreiner, " Verification of dose plans using film dosimetry for quality assurance in radiosurgery.," Radiosurgery 4, 213-227 (2002). 10.1159/000062344
-
(2002)
Radiosurgery
, vol.4
, pp. 213-227
-
-
MacK, A.1
MacK, G.2
Weltz, D.3
Czempiel, H.4
Kreiner, H.J.5
-
25
-
-
33749872451
-
Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams
-
0144-8420,. 10.1093/rpd/ncj006
-
M. Ahmad, Z. Chen, H. Song, J. Deng, and R. Nath, " Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams.," Radiat. Prot. Dosim. 0144-8420 120, 159-162 (2006). 10.1093/rpd/ncj006
-
(2006)
Radiat. Prot. Dosim.
, vol.120
, pp. 159-162
-
-
Ahmad, M.1
Chen, Z.2
Song, H.3
Deng, J.4
Nath, R.5
-
26
-
-
0031466420
-
GafChromic MD-55: Investigated as a precision dosimeter
-
0094-2405 10.1118/1.598106.
-
N. V. Klassen and L. Van der Zvan, " GafChromic MD-55: Investigated as a precision dosimeter.," Med. Phys. 0094-2405 10.1118/1.598106 24, 1924-1934 (1997).
-
(1997)
Med. Phys.
, vol.24
, pp. 1924-1934
-
-
Klassen, N.V.1
Van Der Zvan, L.2
-
27
-
-
34247503351
-
Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry
-
0031-9155 10.1088/0031-9155/52/1/015.
-
L. Paelinck, W. De Neve, and C. De Wagter, " Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/52/1/015 52, 231-242 (2007).
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 231-242
-
-
Paelinck, L.1
De Neve, W.2
De Wagter, C.3
-
28
-
-
0032727433
-
The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry
-
0094-2405 10.1118/1.598730.
-
J. L. Robar and B. G. Clark, " The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry.," Med. Phys. 0094-2405 10.1118/1.598730 26, 2144-2150 (1999).
-
(1999)
Med. Phys.
, vol.26
, pp. 2144-2150
-
-
Robar, J.L.1
Clark, B.G.2
-
29
-
-
0034088508
-
A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery
-
0094-2405 10.1118/1.598962.
-
J. L. Robar and B. G. Clark, " A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.," Med. Phys. 0094-2405 10.1118/1.598962 27, 978-987 (2000).
-
(2000)
Med. Phys.
, vol.27
, pp. 978-987
-
-
Robar, J.L.1
Clark, B.G.2
-
30
-
-
85024787603
-
Characterization and use of EBT radiochromic film for IMRT dose verification
-
0094-2405 10.1118/1.2360012.
-
O. A. Zeidan, S. A. L. Stephenson, S. L. Meeks, T. H. Wagner, T. R. Willoughby, P. A. Kupelian, and K. M. Langen, " Characterization and use of EBT radiochromic film for IMRT dose verification.," Med. Phys. 0094-2405 10.1118/1.2360012 33, 4064-4072 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 4064-4072
-
-
Zeidan, O.A.1
Stephenson, S.A.L.2
Meeks, S.L.3
Wagner, T.H.4
Willoughby, T.R.5
Kupelian, P.A.6
Langen, K.M.7
-
31
-
-
51349090600
-
Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification
-
S. Suriyapee, N. Pitaxtarnin, S. Oonsiri, C. Jumpangern, I. Israngul, and N. Ayuthaya, " Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.," Biomedical Imaging Intervention 4, 1-12 (2008).
-
(2008)
Biomedical Imaging Intervention
, vol.4
, pp. 1-12
-
-
Suriyapee, S.1
Pitaxtarnin, N.2
Oonsiri, S.3
Jumpangern, C.4
Israngul, I.5
Ayuthaya, N.6
-
32
-
-
3142727652
-
EDR2 film dosimetry for IMRT verification using low-energy photon filters
-
0094-2405 10.1118/1.1760190.
-
I. J. Yeo, A. B. Ardakani, Y. B. Cho, M. Heydarian, T. Zhang, and M. Islam, " EDR2 film dosimetry for IMRT verification using low-energy photon filters.," Med. Phys. 0094-2405 10.1118/1.1760190 31, 1960-1963 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 1960-1963
-
-
Yeo, I.J.1
Ardakani, A.B.2
Cho, Y.B.3
Heydarian, M.4
Zhang, T.5
Islam, M.6
-
33
-
-
34347377755
-
Analysis of the sources of uncertainty for EDR2 film-based IMRT quality assurance
-
1526-9914 10.1120/jacmv7i2.2230.
-
C. Shi, N. Papanikolaou, Y. Yan, X. Weng, and H. Jiang, " Analysis of the sources of uncertainty for EDR2 film-based IMRT quality assurance.," J. Appl. Clin. Med. Phys. 1526-9914 10.1120/jacmp.v7i2.2230 7, 1-8 (2006).
-
(2006)
J. Appl. Clin. Med. Phys.
, vol.7
, pp. 1-8
-
-
Shi, C.1
Papanikolaou, N.2
Yan, Y.3
Weng, X.4
Jiang, H.5
-
34
-
-
33746898695
-
Evaluation of Gafchromic EBT film for intensity modulated radiation therapy dose distribution verification
-
A. Sankar, P. G. G. Kurup, V. Murali, K. M. Ayyangar, R. M. Nehru, and J. Velmurugan, " Evaluation of Gafchromic EBT film for intensity modulated radiation therapy dose distribution verification.," Journal of Medical Physics 31, 78-82 (2006).
-
(2006)
Journal of Medical Physics
, vol.31
, pp. 78-82
-
-
Sankar, A.1
Kurup, P.G.G.2
Murali, V.3
Ayyangar, K.M.4
Nehru, R.M.5
Velmurugan, J.6
-
35
-
-
33750510893
-
Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification
-
0739-0211,. 10.1016/j.meddos.2006.06.001
-
A. Sankar, K. M. Ayyangar, R. M. Nehru, P. G. G. Kurup, V. Murali, C. A. Enke, and J. Velmurugan, " Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification.," Med. Dosim. 0739-0211 31, 273-282 (2006). 10.1016/j.meddos.2006.06.001
-
(2006)
Med. Dosim.
, vol.31
, pp. 273-282
-
-
Sankar, A.1
Ayyangar, K.M.2
Nehru, R.M.3
Kurup, P.G.G.4
Murali, V.5
Enke, C.A.6
Velmurugan, J.7
-
37
-
-
58149210333
-
PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter
-
0168-583X 10.1016/0168-583X(95)00349-5.
-
J. Baro, J. Sempau, J. M. Fernandez-Varea, and F. Salvat, "' PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter.," Nucl. Instrum. Methods Phys. Res. B 0168-583X 10.1016/0168-583X(95)00349-5 100, 31-46 (1995).
-
(1995)
Nucl. Instrum. Methods Phys. Res. B
, vol.100
, pp. 31-46
-
-
Baro, J.1
Sempau, J.2
Fernandez-Varea, J.M.3
Salvat, F.4
-
38
-
-
0003410374
-
-
Informes Tecnicos CIEMAT No. 799, Madrid, Spain.
-
F. Salvat, J. M. Fernandez-Varea, J. Baro and J. Sempau, " PENELOPE, an algorithm and computer code for Monte Carlo simulation of electron-photon shower.," Informes Tecnicos CIEMAT No. 799, Madrid, Spain, 1996.
-
(1996)
PENELOPE, An Algorithm and Computer Code for Monte Carlo Simulation of Electron-photon Shower
-
-
Salvat, F.1
Fernandez-Varea, J.M.2
Baro, J.3
Sempau, J.4
-
39
-
-
63849324254
-
Unintended attenuation in the Leksell Gamma Knife Perfexion calibration-phantom adaptor and its effect on dose calibration
-
10.1118/1.3093240
-
J. P. Bhatnagar, J. Novotny Jr., M. A. Quader, G. Bednarz, and M. S. Huq, " Unintended attenuation in the Leksell Gamma Knife Perfexion calibration-phantom adaptor and its effect on dose calibration.," Med. Phys. 36, 1208-1211 (2009). 10.1118/1.3093240
-
(2009)
Med. Phys.
, vol.36
, pp. 1208-1211
-
-
Bhatnagar, J.P.1
Novotny Jr., J.2
Quader, M.A.3
Bednarz, G.4
Huq, M.S.5
|