Volumn 7, Issue 2, 2006, Pages 1-8

Analysis of the sources of uncertainty for EDR2 film-based IMRT quality assurance

Author keywords

Calibration curve; EDR2; Film dosimetry; IMRT; Uncertainty

Indexed keywords

ARTICLE; CALIBRATION; FILM DOSIMETER; HEALTH CARE QUALITY; HUMAN; INTENSITY MODULATED RADIATION THERAPY; STANDARD; UNCERTAINTY; X RAY FILM;

EID: 34347377755     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v7i2.2230     Document Type: Article
Times cited : (26)

References (7)
  • 1
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    • Zhu XR, Jursinic PA, Grimm DF, Lopez F, Rownd JJ, Gillin MT. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys. 2002;29:1687-1692.
    • (2002) Med Phys , vol.29 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6
  • 2
    • 0142025621 scopus 로고    scopus 로고
    • The response of Kodak EDR2 film in high-energy electron beams
    • Gerbi BJ, Dimitroyannis DA. The response of Kodak EDR2 film in high-energy electron beams. Med Phys. 2003;30:2703-2705.
    • (2003) Med Phys , vol.30 , pp. 2703-2705
    • Gerbi, B.J.1    Dimitroyannis, D.A.2
  • 3
    • 0037153141 scopus 로고    scopus 로고
    • Comparative evaluation of Kodak EDR2 and XV 2 films for verification of intensity modulated radiation therapy
    • Dogan N, Leybovich LB, Sethi A. Comparative evaluation of Kodak EDR2 and XV 2 films for verification of intensity modulated radiation therapy. Phys Med Biol. 2002;47:4121-4130. '
    • (2002) Phys Med Biol , vol.47 , pp. 4121-4130
    • Dogan, N.1    Leybovich, L.B.2    Sethi, A.3
  • 4
    • 14644419015 scopus 로고    scopus 로고
    • Dosimetric accuracy of Kodak EDR2 film for IMRT verifications
    • Childress NL, Salehpour M, Dong L, Bloch C. Dosimetric accuracy of Kodak EDR2 film for IMRT verifications. Med Phys. 2005;32:539-548.
    • (2005) Med Phys , vol.32 , pp. 539-548
    • Childress, N.L.1    Salehpour, M.2    Dong, L.3    Bloch, C.4
  • 5
    • 12744273439 scopus 로고    scopus 로고
    • Calibration of Kodak EDR2 film for patient skin dose asessment in cardiac catheterization procedures
    • Morrell RE, Rogers A. Calibration of Kodak EDR2 film for patient skin dose asessment in cardiac catheterization procedures. Phys Med Biol. 2004;49:5559-5570.
    • (2004) Phys Med Biol , vol.49 , pp. 5559-5570
    • Morrell, R.E.1    Rogers, A.2
  • 7
    • 21144451652 scopus 로고    scopus 로고
    • Past radiographic film calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification
    • Yan Y, Papanikolaou N, Weng X, Penagaricano J, Ratanatharathorn V. Past radiographic film calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification. Med Phys. 2005;32:1566-1570.
    • (2005) Med Phys , vol.32 , pp. 1566-1570
    • Yan, Y.1    Papanikolaou, N.2    Weng, X.3    Penagaricano, J.4    Ratanatharathorn, V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.