메뉴 건너뛰기




Volumn 34, Issue 3, 2007, Pages 1007-1012

Measurement of Gamma Knife® helmet factors using MOSFETs

Author keywords

[No Author keywords available]

Indexed keywords

DOSIMETERS; METALS; MOS DEVICES; OXIDE SEMICONDUCTORS; SAFETY DEVICES;

EID: 33847655528     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2437282     Document Type: Article
Times cited : (22)

References (21)
  • 1
    • 33847647742 scopus 로고    scopus 로고
    • Gamma Knife technology and physics: Past, present and future, progress in neurological surgery
    • edited by L. D.Lunsford, D.Kondziolka, and J. C.Flickinger (Karger, Basel
    • A. Maitz, J. C. Flickinger, and L. D. Lunsford, " Gamma Knife technology and physics: Past, present and future, progress in neurological surgery., " in Gamma Knife Surgery, edited by, L. D. Lunsford,,, D. Kondziolka,, and, J. C. Flickinger, (Karger, Basel, 1998), Vol. 14, pp. 5-20.
    • (1998) Gamma Knife Surgery , vol.14 , pp. 5-20
    • Maitz, A.1    Flickinger, J.C.2    Lunsford, L.D.3
  • 2
    • 85027218122 scopus 로고
    • AAPM Report No. 54, Stereotactic Radiosurgery, Task Grou42 Radiation Therapy Committee (American Institute of Physics, New York
    • AAPM Report No. 54, Stereotactic Radiosurgery, Task Group 42 Radiation Therapy Committee (American Institute of Physics, New York, 1995).
    • (1995)
  • 4
    • 0038247942 scopus 로고    scopus 로고
    • Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors
    • J. S. Tsai, M. Rivard, M. Engler, J. Mignano, D. Wazer, and W. Shucart, " Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors., " Med. Phys. 30, 986-992 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 986-992
    • Tsai, J.S.1    Rivard, M.2    Engler, M.3    Mignano, J.4    Wazer, D.5    Shucart, W.6
  • 5
    • 0026466465 scopus 로고
    • Physics and dosimetry of the Gamma Knife
    • A. Wu, " Physics and dosimetry of the Gamma Knife., " Neurosurg. Clin. N. Am. 3, 35-50 (1992).
    • (1992) Neurosurg. Clin. N. Am. , vol.3 , pp. 35-50
    • Wu, A.1
  • 7
    • 0032762524 scopus 로고    scopus 로고
    • Monte Carlo calculated output factors of a Leksell Gamma Knife unit
    • J. Cheung, K. N. Yu, R. Ho, and C. P. Yu, " Monte Carlo calculated output factors of a Leksell Gamma Knife unit., " Phys. Med. Biol. 44, N247-N249 (1999).
    • (1999) Phys. Med. Biol. , vol.44
    • Cheung, J.1    Yu, K.N.2    Ho, R.3    Yu, C.P.4
  • 9
    • 0041387395 scopus 로고    scopus 로고
    • ® helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector
    • ® helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector., " Med. Phys. 30, 1976-1981 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1976-1981
    • Araki, F.1    Ikegami, T.2    Ishidoya, T.3    Kubo, H.D.4
  • 11
    • 33847647743 scopus 로고    scopus 로고
    • T. Nielsen, Operator's Manual MOSFET 20, Version 3.1, document No. 100237.15, August, 2003.
    • (2003)
    • Nielsen, T.1
  • 12
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • M. Soubra, J. Cygler, and G. Mackay, " Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter., " Med. Phys. 21, 567-572 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    MacKay, G.3
  • 13
    • 0035990040 scopus 로고    scopus 로고
    • Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    • C. F. Chuang, L. J. Verhey, and P. Xia, " Investigation of the use of MOSFET for clinical IMRT dosimetric verification., " Med. Phys. 29, 1109-1115 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1109-1115
    • Chuang, C.F.1    Verhey, L.J.2    Xia, P.3
  • 16
    • 85027241689 scopus 로고    scopus 로고
    • C. Yu (private communication).
    • Yu, C.1
  • 19
    • 0037368686 scopus 로고    scopus 로고
    • Characterization of the angular response of an isotropic MOSFET dosimeter
    • J. N. Roshau and D. E. Hintenlang, " Characterization of the angular response of an isotropic MOSFET dosimeter., " Health Phys. 84, 376-379 (2003).
    • (2003) Health Phys. , vol.84 , pp. 376-379
    • Roshau, J.N.1    Hintenlang, D.E.2
  • 21
    • 85027220141 scopus 로고    scopus 로고
    • Leksell Gamma Knife Model C Instructions for Use, Chap., Doc. Art. No.: 005232 Rev. 02, April
    • Leksell Gamma Knife Model C Instructions for Use, Chap., Doc. Art. No.: 005232 Rev. 02, April, 2000.
    • (2000)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.