메뉴 건너뛰기




Volumn 31, Issue 5, 2004, Pages 1243-1248

GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy

Author keywords

[No Author keywords available]

Indexed keywords

MEDICAL APPLICATIONS; PIXELS; SCANNING;

EID: 2442701589     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1712393     Document Type: Article
Times cited : (14)

References (8)
  • 1
    • 0008796868 scopus 로고    scopus 로고
    • Radiochromic film dosimetry. Recommendations of AAPM Radiation Therapy Committee Task Group 55
    • A. Niroomand-Rad et al., "Radiochromic film dosimetry. Recommendations of AAPM Radiation Therapy Committee Task Group 55," Med. Phys. 25, 2093-2115 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2093-2115
    • Niroomand-Rad, A.1
  • 2
    • 0031466420 scopus 로고    scopus 로고
    • GafChromic MD-55: Investigated as a precision dosimeter
    • N. V. Klassen et al., "GafChromic MD-55: Investigated as a precision dosimeter," Med. Phys. 24, 1924-1934 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1924-1934
    • Klassen, N.V.1
  • 3
    • 0025895699 scopus 로고
    • Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry
    • P. J. Muench et al., "Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry," Med. Phys. 18, 769-775 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 769-775
    • Muench, P.J.1
  • 4
    • 0032726570 scopus 로고    scopus 로고
    • An application of GafChromic MD-55-2 film for 67.5 MeV clinical proton beam dosimetry
    • I. Daftari et al., "An application of GafChromic MD-55-2 film for 67.5 MeV clinical proton beam dosimetry," Phys. Med. Biol. 44, 2735-2745 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2735-2745
    • Daftari, I.1
  • 5
    • 0033940082 scopus 로고    scopus 로고
    • 2D and 3D dose distribution determination in proton beam radiotherapy with GafChromic™ film detectors
    • S. O. Troja et al., "2D and 3D dose distribution determination in proton beam radiotherapy with GafChromic™ film detectors," Technol. Health Care 8, 155-164 (2000).
    • (2000) Technol. Health Care , vol.8 , pp. 155-164
    • Troja, S.O.1
  • 6
    • 0034037793 scopus 로고    scopus 로고
    • Quality assurance for an image-guided frameless radiosurgery system using radiochromic film
    • H. Shiomi et al., "Quality assurance for an image-guided frameless radiosurgery system using radiochromic film," Radiat. Med. 18, 107-113 (2000).
    • (2000) Radiat. Med. , vol.18 , pp. 107-113
    • Shiomi, H.1
  • 7
    • 33646664390 scopus 로고    scopus 로고
    • Usefulness of a dose distribution analysis system with a common scanner
    • T. Nakashima et al., "Usefulness of a dose distribution analysis system with a common scanner," Japanese J. of Radiological Technol. 58, 833-839 (2002).
    • (2002) Japanese J. of Radiological Technol. , vol.58 , pp. 833-839
    • Nakashima, T.1
  • 8
    • 0034666808 scopus 로고    scopus 로고
    • Stereotactic dose planning system used in Leksell Gamma Knife model-B: EGS4 Monte Carlo versus GafChromic films MD-55
    • Y. C. Cheung et al., "Stereotactic dose planning system used in Leksell Gamma Knife model-B: EGS4 Monte Carlo versus GafChromic films MD-55," Appl. Radiat. Isot. 53, 427-430 (2000).
    • (2000) Appl. Radiat. Isot. , vol.53 , pp. 427-430
    • Cheung, Y.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.