Volumn 36, Issue 4, 2009, Pages 1199-1207

Optimization of the acquisition geometry in digital tomosynthesis of the breast

Author keywords

breast; digital mammography; optimization; reconstruction; Tomosynthesis

Indexed keywords

GEOMETRY; IMAGE RECONSTRUCTION; MEDICAL IMAGING; MERGERS AND ACQUISITIONS; OPTIMIZATION;

EID: 63849136026     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3090889     Document Type: Article
Times cited : (142)

References (44)
  • 1
  • 3
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • 0031-9155 10.1088/0031-9155/48/19/R01.
    • J. T. Dobbins III and D. J. Godfrey, " Digital x-ray tomosynthesis: Current state of the art and clinical potential.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/48/19/R01 48, R65-R106 (2003).
    • (2003) Phys. Med. Biol. , vol.48
    • Dobbins III, J.T.1    Godfrey, D.J.2
  • 4
    • 33845927292 scopus 로고    scopus 로고
    • Computation of the glandular radiation dose in digital tomosynthesis of the breast
    • 0094-2405 10.1118/1.2400836.
    • I. Sechopoulos, S. Suryanarayanan, S. Vedantham, C. D'Orsi, and A. Karellas, " Computation of the glandular radiation dose in digital tomosynthesis of the breast.," Med. Phys. 0094-2405 10.1118/1.2400836 34, 221-232 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 221-232
    • Sechopoulos, I.1    Suryanarayanan, S.2    Vedantham, S.3    D'orsi, C.4    Karellas, A.5
  • 5
    • 33846643985 scopus 로고    scopus 로고
    • Scatter radiation in digital tomosynthesis of the breast
    • 0094-2405 10.1118/1.2428404.
    • I. Sechopoulos, S. Suryanarayanan, S. Vedantham, C. J. D'Orsi, and A. Karellas, " Scatter radiation in digital tomosynthesis of the breast.," Med. Phys. 0094-2405 10.1118/1.2428404 34, 564-576 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 564-576
    • Sechopoulos, I.1    Suryanarayanan, S.2    Vedantham, S.3    D'orsi, C.J.4    Karellas, A.5
  • 6
    • 33846186878 scopus 로고    scopus 로고
    • Initial clinical experience with contrast-enhanced digital breast tomosynthesis
    • 1076-6332
    • S. C. Chen, A. K. Carton, M. Albert, E. F. Conant, M. D. Schnall, and A. D. Maidment, " Initial clinical experience with contrast-enhanced digital breast tomosynthesis.," Acad. Radiol. 14, 229-238 (2007). 1076-6332
    • (2007) Acad. Radiol. , vol.14 , pp. 229-238
    • Chen, S.C.1    Carton, A.K.2    Albert, M.3    Conant, E.F.4    Schnall, M.D.5    Maidment, A.D.6
  • 7
    • 35148820740 scopus 로고    scopus 로고
    • Optimization of image quality in breast tomosynthesis using lumpectomy and mastectomy specimens
    • 0277-786X
    • P. Timberg, M. Ruschin, M. Bth, B. Hemdal, I. Andersson, T. Svahn, S. Mattsson, and A. Tingberg, " Optimization of image quality in breast tomosynthesis using lumpectomy and mastectomy specimens.," Proc. SPIE 6510, 651032-651038 (2007). 0277-786X
    • (2007) Proc. SPIE , vol.6510 , pp. 651032-651038
    • Timberg, P.1    Ruschin, M.2    Bth, M.3    Hemdal, B.4    Andersson, I.5    Svahn, T.6    Mattsson, S.7    Tingberg, A.8
  • 8
    • 35148874776 scopus 로고    scopus 로고
    • A new approach to digital breast tomosynthesis for breast cancer screening
    • 0277-786X 10.1117/12.713677.
    • R. M. Nishikawa, I. Reiser, P. Seifi, and C. J. Vyborny, " A new approach to digital breast tomosynthesis for breast cancer screening.," Proc. SPIE 0277-786X 10.1117/12.713677 6510, 65103C-65108C (2007).
    • (2007) Proc. SPIE , vol.6510
    • Nishikawa, R.M.1    Reiser, I.2    Seifi, P.3    Vyborny, C.J.4
  • 9
    • 35648983440 scopus 로고    scopus 로고
    • Anisotropic imaging performance in breast tomosynthesis
    • 0094-2405 10.1118/1.2779943.
    • A. Badano, I. S. Kyprianou, R. J. Jennings, and J. Sempau, " Anisotropic imaging performance in breast tomosynthesis.," Med. Phys. 0094-2405 10.1118/1.2779943 34, 4076-4091 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 4076-4091
    • Badano, A.1    Kyprianou, I.S.2    Jennings, R.J.3    Sempau, J.4
  • 13
    • 34548225376 scopus 로고    scopus 로고
    • Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography
    • 0361-803X 10.2214/AJR.07.2231.
    • S. P. Poplack, T. D. Tosteson, C. A. Kogel, and H. M. Nagy, " Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography.," AJR, Am. J. Roentgenol. 0361-803X 10.2214/AJR.07.2231 189, 616-623 (2007).
    • (2007) AJR, Am. J. Roentgenol. , vol.189 , pp. 616-623
    • Poplack, S.P.1    Tosteson, T.D.2    Kogel, C.A.3    Nagy, H.M.4
  • 14
    • 35148833931 scopus 로고    scopus 로고
    • Optimization of detector operation and imaging geometry for breast tomosynthesis
    • 0277-786X 10.1117/12.713718.
    • W. Zhao, B. Zhao, P. R. Fisher, P. Warmoes, T. Mertelmeier, and J. Orman, " Optimization of detector operation and imaging geometry for breast tomosynthesis.," Proc. SPIE 0277-786X 10.1117/12.713718 6510, 65101M-65112M (2007).
    • (2007) Proc. SPIE , vol.6510
    • Zhao, W.1    Zhao, B.2    Fisher, P.R.3    Warmoes, P.4    Mertelmeier, T.5    Orman, J.6
  • 16
    • 3042639644 scopus 로고    scopus 로고
    • Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method
    • 0277-786X 10.1117/12.534446.
    • T. Wu, J. Zhang, R. Moore, E. Rafferty, D. Kopans, W. Meleis, and D. Kaeli, " Digital tomosynthesis mammography using a parallel maximum-likelihood reconstruction method.," Proc. SPIE 0277-786X 10.1117/12.534446 5368, 1-11 (2004).
    • (2004) Proc. SPIE , vol.5368 , pp. 1-11
    • Wu, T.1    Zhang, J.2    Moore, R.3    Rafferty, E.4    Kopans, D.5    Meleis, W.6    Kaeli, D.7
  • 18
    • 34347399809 scopus 로고    scopus 로고
    • Physical characteristics of five clinical systems for digital mammography
    • 0094-2405 10.1118/1.2742498.
    • B. Lazzari, G. Belli, C. Gori, and M. Rosselli Del Turco, " Physical characteristics of five clinical systems for digital mammography.," Med. Phys. 0094-2405 10.1118/1.2742498 34, 2730-2743 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 2730-2743
    • Lazzari, B.1    Belli, G.2    Gori, C.3    Rosselli Del Turco, M.4
  • 19
    • 38849146317 scopus 로고    scopus 로고
    • Physical characteristics of GE Senographe Essential and DS digital mammography detectors
    • 0094-2405 10.1118/1.2828185.
    • C. Ghetti, A. Borrini, O. Ortenzia, R. Rossi, and P. L. Ordonez, " Physical characteristics of GE Senographe Essential and DS digital mammography detectors.," Med. Phys. 0094-2405 10.1118/1.2828185 35, 456-463 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 456-463
    • Ghetti, C.1    Borrini, A.2    Ortenzia, O.3    Rossi, R.4    Ordonez, P.L.5
  • 23
    • 33847676189 scopus 로고    scopus 로고
    • A computer simulation platform for the optimization of a breast tomosynthesis system
    • 0094-2405 10.1118/1.2558160.
    • J. Zhou, B. Zhao, and W. Zhao, " A computer simulation platform for the optimization of a breast tomosynthesis system.," Med. Phys. 0094-2405 10.1118/1.2558160 34, 1098-1109 (2007).
    • (2007) Med. Phys. , vol.34 , pp. 1098-1109
    • Zhou, J.1    Zhao, B.2    Zhao, W.3
  • 25
    • 85027217429 scopus 로고    scopus 로고
    • Anatomical noise in breast images: Noise power spectrum comparisons between mammography and dedicated breast CT
    • (Radiological Society of North America, Chicago, IL),.
    • J. M. Boone, K. M. Metheany, and C. K. Abbey, " Anatomical noise in breast images: Noise power spectrum comparisons between mammography and dedicated breast CT.," Radiological Society of North America 93rd Scientific Assembly and Annual Meeting Program (Radiological Society of North America, Chicago, IL, 2007), p. 451.
    • (2007) Radiological Society of North America 93rd Scientific Assembly and Annual Meeting Program , pp. 451
    • Boone, J.M.1    Metheany, K.M.2    Abbey, C.K.3
  • 26
    • 0033735247 scopus 로고    scopus 로고
    • Scatter/primary in mammography: Comprehensive results
    • 0094-2405 10.1118/1.1312812.
    • J. M. Boone, K. K. Lindfors, V. N. Cooper 3rd, and J. A. Seibert, " Scatter/primary in mammography: Comprehensive results.," Med. Phys. 0094-2405 10.1118/1.1312812 27, 2408-2416 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2408-2416
    • Boone, J.M.1    Lindfors, K.K.2    Cooper III, V.N.3    Seibert, J.A.4
  • 27
    • 0036703710 scopus 로고    scopus 로고
    • A dual-energy subtraction technique for microcalcification imaging in digital mammography-A signal-to-noise analysis
    • 0094-2405 10.1118/1.1494832.
    • M. R. Lemacks, S. C. Kappadath, C. C. Shaw, X. Liu, and G. J. Whitman, " A dual-energy subtraction technique for microcalcification imaging in digital mammography-A signal-to-noise analysis.," Med. Phys. 0094-2405 10.1118/1.1494832 29, 1739-1751 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1739-1751
    • Lemacks, M.R.1    Kappadath, S.C.2    Shaw, C.C.3    Liu, X.4    Whitman, G.J.5
  • 28
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • 0094-2405 10.1118/1.595715.
    • R. L. Siddon, " Fast calculation of the exact radiological path for a three-dimensional CT array.," Med. Phys. 0094-2405 10.1118/1.595715 12, 252-255 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 252-255
    • Siddon, R.L.1
  • 29
    • 63849142013 scopus 로고    scopus 로고
    • Ph.D. thesis, Georgia Institute of Technology.
    • I. Sechopoulos, Ph.D. thesis, Georgia Institute of Technology, 2007.
    • (2007)
    • Sechopoulos, I.1
  • 30
    • 0031466296 scopus 로고    scopus 로고
    • Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    • 0094-2405 10.1118/1.598100.
    • J. M. Boone, T. R. Fewell, and R. J. Jennings, " Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography.," Med. Phys. 0094-2405 10.1118/1.598100 24, 1863-1874 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1863-1874
    • Boone, J.M.1    Fewell, T.R.2    Jennings, R.J.3
  • 32
    • 0041461316 scopus 로고    scopus 로고
    • A method for modifying the image quality parameters of digital radiographic images
    • 0094-2405 10.1118/1.1621870.
    • R. S. Saunders, Jr. and E. Samei, " A method for modifying the image quality parameters of digital radiographic images.," Med. Phys. 0094-2405 10.1118/1.1621870 30, 3006-3017 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 3006-3017
    • Saunders Jr., R.S.1    Samei, E.2
  • 33
    • 33748303079 scopus 로고    scopus 로고
    • Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis
    • 0094-2405 10.1118/1.2241994.
    • J. G. Mainprize, A. K. Bloomquist, M. P. Kempston, and M. J. Yaffe, " Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis.," Med. Phys. 0094-2405 10.1118/1.2241994 33, 3159-3164 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 3159-3164
    • Mainprize, J.G.1    Bloomquist, A.K.2    Kempston, M.P.3    Yaffe, M.J.4
  • 34
    • 0017501583 scopus 로고
    • A maximum likelihood approach to transmission image reconstruction from projections
    • 0018-9499
    • A. J. Rockmore and A. Macovski, " A maximum likelihood approach to transmission image reconstruction from projections.," IEEE Trans. Nucl. Sci. 24, 1929-1935 (1977). 0018-9499
    • (1977) IEEE Trans. Nucl. Sci. , vol.24 , pp. 1929-1935
    • Rockmore, A.J.1    Macovski, A.2
  • 35
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • 0278-0062 10.1109/TMI.1982.4307558.
    • L. A. Shepp and Y. Vardi, " Maximum likelihood reconstruction for emission tomography.," IEEE Trans. Med. Imaging 0278-0062 10.1109/TMI.1982.4307558 1, 113-122 (1982).
    • (1982) IEEE Trans. Med. Imaging , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 36
    • 0023421482 scopus 로고
    • A maximum a posteriori probability expectation maximization algorithm or image reconstruction in emission tomography
    • 0278-0062
    • E. Levitan and G. T. Herman, " A maximum a posteriori probability expectation maximization algorithm or image reconstruction in emission tomography.," IEEE Trans. Med. Imaging 6, 185-192 (1987). 0278-0062
    • (1987) IEEE Trans. Med. Imaging , vol.6 , pp. 185-192
    • Levitan, E.1    Herman, G.T.2
  • 37
    • 0024681039 scopus 로고
    • A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
    • 0278-0062 10.1109/42.24868.
    • T. Hebert and R. Leahy, " A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors.," IEEE Trans. Med. Imaging 0278-0062 10.1109/42.24868 8, 194-202 (1989).
    • (1989) IEEE Trans. Med. Imaging , vol.8 , pp. 194-202
    • Hebert, T.1    Leahy, R.2
  • 38
    • 0026837707 scopus 로고
    • Developments with maximum likelihood X-ray computed tomography
    • 0278-0062
    • J. A. Browne and T. J. Holmes, " Developments with maximum likelihood X-ray computed tomography.," IEEE Trans. Med. Imaging 11, 40-52 (1992). 0278-0062
    • (1992) IEEE Trans. Med. Imaging , vol.11 , pp. 40-52
    • Browne, J.A.1    Holmes, T.J.2
  • 39
    • 0029020079 scopus 로고
    • Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT
    • 0031-9155 10.1088/0031-9155/40/7/006.
    • S. H. Manglos, G. M. Gagne, A. Krol, F. D. Thomas, and R. Narayanaswamy, " Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT.," Phys. Med. Biol. 0031-9155 10.1088/0031-9155/40/7/006 40, 1225-1241 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 1225-1241
    • Manglos, S.H.1    Gagne, G.M.2    Krol, A.3    Thomas, F.D.4    Narayanaswamy, R.5
  • 40
    • 0031195392 scopus 로고    scopus 로고
    • Choice of initial conditions in the ML reconstruction of fan-beam transmission with truncated projection data
    • 0278-0062 10.1109/42.611352.
    • T. -S. Pan, B. M. W. Tsui, and C. L. Byrne, " Choice of initial conditions in the ML reconstruction of fan-beam transmission with truncated projection data.," IEEE Trans. Med. Imaging 0278-0062 10.1109/42.611352 16, 426-438 (1997).
    • (1997) IEEE Trans. Med. Imaging , vol.16 , pp. 426-438
    • Pan, T.-S.1    Tsui, B.M.W.2    Byrne, C.L.3
  • 42
    • 4644334876 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for breast tomosynthesis
    • 0094-2405 10.1118/1.1786692.
    • T. Wu, R. H. Moore, E. A. Rafferty, and D. B. Kopans, " A comparison of reconstruction algorithms for breast tomosynthesis.," Med. Phys. 0094-2405 10.1118/1.1786692 31, 2636-2647 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2636-2647
    • Wu, T.1    Moore, R.H.2    Rafferty, E.A.3    Kopans, D.B.4
  • 43
    • 85027221324 scopus 로고    scopus 로고
    • Hologic, Inc. (personal communication).
    • A. Smith, Hologic, Inc. (personal communication).
    • Smith, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.