-
1
-
-
0036720829
-
Ultrasensitive semiautomated chemiluminescent immunoassay for estradiol
-
England B.G., Parsons G.H., Possley R.M., McConnell D.S., and Midgley A.R. Ultrasensitive semiautomated chemiluminescent immunoassay for estradiol. Clin. Chem. 48 (2002) 1584-1586
-
(2002)
Clin. Chem.
, vol.48
, pp. 1584-1586
-
-
England, B.G.1
Parsons, G.H.2
Possley, R.M.3
McConnell, D.S.4
Midgley, A.R.5
-
2
-
-
0036183463
-
Limitations of steroid determination by direct immunoassay
-
Taieb J., Benattar C., Birr A.S., and Lindenbaum A. Limitations of steroid determination by direct immunoassay. Clin. Chem. 48 (2002) 583-585
-
(2002)
Clin. Chem.
, vol.48
, pp. 583-585
-
-
Taieb, J.1
Benattar, C.2
Birr, A.S.3
Lindenbaum, A.4
-
3
-
-
23144447605
-
Analysis of anabolic steroids in the horse: development of a generic ELISA for the screening of 17α-alkyl anabolic steroid metabolites
-
Hungerford N.L., Sortais B., Smart A.G., McKinney A.R., Ridley D.D., Stenhouse A.M., Suann C.J., Munn K.J., Sillence M.N., and McLeod M.D. Analysis of anabolic steroids in the horse: development of a generic ELISA for the screening of 17α-alkyl anabolic steroid metabolites. J. Steroid Biochem. Mol. Biol. 96 (2005) 317-334
-
(2005)
J. Steroid Biochem. Mol. Biol.
, vol.96
, pp. 317-334
-
-
Hungerford, N.L.1
Sortais, B.2
Smart, A.G.3
McKinney, A.R.4
Ridley, D.D.5
Stenhouse, A.M.6
Suann, C.J.7
Munn, K.J.8
Sillence, M.N.9
McLeod, M.D.10
-
4
-
-
23144459650
-
Novel biosensors for the detection of estrogen receptor ligands
-
De S., Macara I.G., and Lannigan D.A. Novel biosensors for the detection of estrogen receptor ligands. J. Steroid Biochem. Mol. Biol. 96 (2005) 235-244
-
(2005)
J. Steroid Biochem. Mol. Biol.
, vol.96
, pp. 235-244
-
-
De, S.1
Macara, I.G.2
Lannigan, D.A.3
-
5
-
-
20944439398
-
HX531, a retinoid X receptor antagonist, inhibited the 9-cis retinoic acid-induced binding with steroid receptor coactivator-1 as detected by surface plasmom resonance
-
Toshie K.T., Tomofumi F., Tadashi O., Takayoshi S., Tomoko N.M., Yoji S., Swada J.I., Inoue K.A., Koichi S., Yasuo O., and Teruhide Y. HX531, a retinoid X receptor antagonist, inhibited the 9-cis retinoic acid-induced binding with steroid receptor coactivator-1 as detected by surface plasmom resonance. J. Steroid Biochem. Mol. Biol. 94 (2005) 303-309
-
(2005)
J. Steroid Biochem. Mol. Biol.
, vol.94
, pp. 303-309
-
-
Toshie, K.T.1
Tomofumi, F.2
Tadashi, O.3
Takayoshi, S.4
Tomoko, N.M.5
Yoji, S.6
Swada, J.I.7
Inoue, K.A.8
Koichi, S.9
Yasuo, O.10
Teruhide, Y.11
-
6
-
-
46749097191
-
Detection of the administration of 17β-nortestosterone in boars by gas chromatography/mass spectrometry
-
Ventura R., Roig M., Perez B., Lopex S., Medina M., Bosch J., and Segura J. Detection of the administration of 17β-nortestosterone in boars by gas chromatography/mass spectrometry. Rapid Commun. Mass Spectrom. 22 (2008) 1863-1870
-
(2008)
Rapid Commun. Mass Spectrom.
, vol.22
, pp. 1863-1870
-
-
Ventura, R.1
Roig, M.2
Perez, B.3
Lopex, S.4
Medina, M.5
Bosch, J.6
Segura, J.7
-
7
-
-
43649092029
-
Gas chromatography-mass spectrometry method for the analysis of 19-nor-4-androstenediol and metabolites in human plasma: Application to pharmacokinetic studies after oral administration of a prohormone supplement
-
Torrado S., Segura J., Farre M., and Ventura R. Gas chromatography-mass spectrometry method for the analysis of 19-nor-4-androstenediol and metabolites in human plasma: Application to pharmacokinetic studies after oral administration of a prohormone supplement. Steroids 73 (2008) 751-759
-
(2008)
Steroids
, vol.73
, pp. 751-759
-
-
Torrado, S.1
Segura, J.2
Farre, M.3
Ventura, R.4
-
8
-
-
41549161611
-
Quantitative determination of progesterones and corticosteroids in human urine using gas chromatography/mass spectrometry: application to pelvic organ prolapsed patients
-
Shama N., Bai S.W., Chung B.C., and Jung B.H. Quantitative determination of progesterones and corticosteroids in human urine using gas chromatography/mass spectrometry: application to pelvic organ prolapsed patients. Rapid Commun. Mass Spectrom. 22 (2008) 959-964
-
(2008)
Rapid Commun. Mass Spectrom.
, vol.22
, pp. 959-964
-
-
Shama, N.1
Bai, S.W.2
Chung, B.C.3
Jung, B.H.4
-
9
-
-
42949149708
-
Hydrophilic interaction liquid chromatography-tandem mass spectrometry determination of estrogen conjugations in human urine
-
Qin F., Zhao Y.-Y., Sawyer M.B., and Li X.-F. Hydrophilic interaction liquid chromatography-tandem mass spectrometry determination of estrogen conjugations in human urine. Anal. Chem. 80 (2008) 3404-3411
-
(2008)
Anal. Chem.
, vol.80
, pp. 3404-3411
-
-
Qin, F.1
Zhao, Y.-Y.2
Sawyer, M.B.3
Li, X.-F.4
-
10
-
-
39149099108
-
Direct quantification of steroid glucuronides in human urine by liquid chromatography-electrospray tandem mass spectrometry
-
Pozo O.J., Eenoo P.V., Thuyne W.V., Deventer K., and Delbeke F.T. Direct quantification of steroid glucuronides in human urine by liquid chromatography-electrospray tandem mass spectrometry. J. Chromatogr. A 1183 (2008) 108-118
-
(2008)
J. Chromatogr. A
, vol.1183
, pp. 108-118
-
-
Pozo, O.J.1
Eenoo, P.V.2
Thuyne, W.V.3
Deventer, K.4
Delbeke, F.T.5
-
11
-
-
0031238945
-
Determination of steroids by liquid chromatography/mass spectrometry
-
Ma Y.C., and Kim H.Y. Determination of steroids by liquid chromatography/mass spectrometry. J. Am. Soc. Mass Spectrom. 8 (1997) 1010-1020
-
(1997)
J. Am. Soc. Mass Spectrom.
, vol.8
, pp. 1010-1020
-
-
Ma, Y.C.1
Kim, H.Y.2
-
12
-
-
40849123942
-
An optimized, highly sensitive radioimmunoassay for the simultaneous measurement if estrone estradiol and estrone sulfate in the ultra-low range in human plasma samples
-
Geisler J., Ekse D., Helle H., Duong N.K., and Lonning P.E. An optimized, highly sensitive radioimmunoassay for the simultaneous measurement if estrone estradiol and estrone sulfate in the ultra-low range in human plasma samples. J. Steroid Biochem. Mol. Biol. 109 (2008) 90-95
-
(2008)
J. Steroid Biochem. Mol. Biol.
, vol.109
, pp. 90-95
-
-
Geisler, J.1
Ekse, D.2
Helle, H.3
Duong, N.K.4
Lonning, P.E.5
-
13
-
-
31044456138
-
Development and validation of a simple and direct ELISA method for the determination of conjugated (glucuronide) and non-conjugated testosterone excretion in urine
-
Aldujaili E.A.S. Development and validation of a simple and direct ELISA method for the determination of conjugated (glucuronide) and non-conjugated testosterone excretion in urine. Clin. Chim. Acta 364 (2006) 172-179
-
(2006)
Clin. Chim. Acta
, vol.364
, pp. 172-179
-
-
Aldujaili, E.A.S.1
-
15
-
-
0035902938
-
Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species
-
Cui Y., Wei Q., Park H., and Lieber C.M. Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species. Science 293 (2001) 1289-1292
-
(2001)
Science
, vol.293
, pp. 1289-1292
-
-
Cui, Y.1
Wei, Q.2
Park, H.3
Lieber, C.M.4
-
16
-
-
4644230429
-
Electrical detection of single viruses
-
Patolsky F., Zheng G., Hayden O., Lakadamyali M., Zhuang X., and Lieber C.M. Electrical detection of single viruses. Proc. Natl. Acad. Sci. U.S.A. 101 (2004) 14017-14022
-
(2004)
Proc. Natl. Acad. Sci. U.S.A.
, vol.101
, pp. 14017-14022
-
-
Patolsky, F.1
Zheng, G.2
Hayden, O.3
Lakadamyali, M.4
Zhuang, X.5
Lieber, C.M.6
-
17
-
-
33847342833
-
Nanowire labeled direct-charge transfer biosensor for detecting Bacillus species
-
Pal S., Alocilja E.C., and Downes P.F. Nanowire labeled direct-charge transfer biosensor for detecting Bacillus species. Biosens. Bioelectron. 22 (2007) 2329-2336
-
(2007)
Biosens. Bioelectron.
, vol.22
, pp. 2329-2336
-
-
Pal, S.1
Alocilja, E.C.2
Downes, P.F.3
-
18
-
-
24144464524
-
Single-walled carbon nanotube biosensors using aptamers as molecular recognition elements
-
So H.M., Won K., Kim Y.H., Kim B.K., Ryu B.H., Na P.S., Kim H., and Lee J.O. Single-walled carbon nanotube biosensors using aptamers as molecular recognition elements. J. Am. Chem. Soc. 127 (2005) 11906-11907
-
(2005)
J. Am. Chem. Soc.
, vol.127
, pp. 11906-11907
-
-
So, H.M.1
Won, K.2
Kim, Y.H.3
Kim, B.K.4
Ryu, B.H.5
Na, P.S.6
Kim, H.7
Lee, J.O.8
-
19
-
-
2342663629
-
An FET-type charge sensor for highly sensitive detection of DNA sequence
-
Kim D.S., Jeong Y.T., Park H.J., Shin J.K., Choi P., Lee J.H., and Lim G. An FET-type charge sensor for highly sensitive detection of DNA sequence. Biosens. Bioelectron. 20 (2004) 69-74
-
(2004)
Biosens. Bioelectron.
, vol.20
, pp. 69-74
-
-
Kim, D.S.1
Jeong, Y.T.2
Park, H.J.3
Shin, J.K.4
Choi, P.5
Lee, J.H.6
Lim, G.7
-
20
-
-
0141521856
-
Enzyme-coated carbon nanotubes as single-molecule biosensors
-
Besteman K., Lee J.O., Wiertz F.G.M., Heering H.A., and Dekker C. Enzyme-coated carbon nanotubes as single-molecule biosensors. Nano Lett. 3 (2003) 727-730
-
(2003)
Nano Lett.
, vol.3
, pp. 727-730
-
-
Besteman, K.1
Lee, J.O.2
Wiertz, F.G.M.3
Heering, H.A.4
Dekker, C.5
-
22
-
-
14744276690
-
Label-free detection of small-molecule-protein interactions by using nanowire nanosensors
-
Wang W.U., Chen C., Lin K.H., Fang Y., and Lieber C.M. Label-free detection of small-molecule-protein interactions by using nanowire nanosensors. Proc. Natl. Acad. Sci. U.S.A. 102 (2005) 3208-3212
-
(2005)
Proc. Natl. Acad. Sci. U.S.A.
, vol.102
, pp. 3208-3212
-
-
Wang, W.U.1
Chen, C.2
Lin, K.H.3
Fang, Y.4
Lieber, C.M.5
-
25
-
-
0025886145
-
5-3-ketosteroid isomerase. Direct spectroscopic evidence for dienol intermediates
-
5-3-ketosteroid isomerase. Direct spectroscopic evidence for dienol intermediates. Biochemistry 30 (1991) 4991-4997
-
(1991)
Biochemistry
, vol.30
, pp. 4991-4997
-
-
Xue, L.1
Kuliopulos, A.2
Mildvan, A.S.3
Talalay, P.4
-
26
-
-
4644373998
-
Enzymatic mechanisms for catalysis of enolization: ketosteroid isomerase
-
Pollack R.M. Enzymatic mechanisms for catalysis of enolization: ketosteroid isomerase. Bioorg Chem. 32 (2004) 341-353
-
(2004)
Bioorg Chem.
, vol.32
, pp. 341-353
-
-
Pollack, R.M.1
-
30
-
-
0028243146
-
5-3-ketosteroid isomerase by time-resolved fluorescence and circular dichroism
-
5-3-ketosteroid isomerase by time-resolved fluorescence and circular dichroism. Biochemistry 33 (1994) 7415-7422
-
(1994)
Biochemistry
, vol.33
, pp. 7415-7422
-
-
Wu, P.1
Li, Y.-K.2
Talalay, P.3
Brand, L.4
-
31
-
-
0001305507
-
5-3-ketosteroid isomerase with and without a reaction intermediate analogue
-
5-3-ketosteroid isomerase with and without a reaction intermediate analogue. Biochemistry 36 (1997) 14030-14036
-
(1997)
Biochemistry
, vol.36
, pp. 14030-14036
-
-
Kim, S.W.1
Cha, S.-S.2
Cho, H.-S.3
Kim, J.-S.4
HA, N.-C.5
Cho, M.-J.6
Joo, S.7
Kim, K.K.8
Choi, K.Y.9
Oh, B.-H.10
-
32
-
-
28544435430
-
In vivo regulatory phosphorylation of novel phosphoenolpyruvate carboxylase isoforms in endosperm of developing castor oil seeds
-
Tripodi K.E., Turner W.L., Gennidakis S., and Plaxton W.C. In vivo regulatory phosphorylation of novel phosphoenolpyruvate carboxylase isoforms in endosperm of developing castor oil seeds. Plant Physiol. 139 (2005) 969-978
-
(2005)
Plant Physiol.
, vol.139
, pp. 969-978
-
-
Tripodi, K.E.1
Turner, W.L.2
Gennidakis, S.3
Plaxton, W.C.4
-
33
-
-
0003051583
-
Controlled nucleation of the regulation of the particle size in monodisperse gold solution
-
Frens G. Controlled nucleation of the regulation of the particle size in monodisperse gold solution. Nat. Phys. Sci. 241 (1973) 20-22
-
(1973)
Nat. Phys. Sci.
, vol.241
, pp. 20-22
-
-
Frens, G.1
-
35
-
-
27644586326
-
Chemical sensors using peptide-functionalized conducting polymer nanojunction arrays
-
Aguilar A.D., Forzani E.S., Li X., Tao N., Nagahara L.A., Amlani I., and Tsui R. Chemical sensors using peptide-functionalized conducting polymer nanojunction arrays. Appl. Phys. Lett. 87 (2005) 193108-193110
-
(2005)
Appl. Phys. Lett.
, vol.87
, pp. 193108-193110
-
-
Aguilar, A.D.1
Forzani, E.S.2
Li, X.3
Tao, N.4
Nagahara, L.A.5
Amlani, I.6
Tsui, R.7
-
36
-
-
33751571782
-
Silicon-based nanoelectronic field-effect pH sensor with local gate control
-
Chen Y., Wang X., Erramilli S., Mohanty P., and Kalinowski A. Silicon-based nanoelectronic field-effect pH sensor with local gate control. Appl. Phys. Lett. 89 (2006) 223512-223514
-
(2006)
Appl. Phys. Lett.
, vol.89
, pp. 223512-223514
-
-
Chen, Y.1
Wang, X.2
Erramilli, S.3
Mohanty, P.4
Kalinowski, A.5
-
37
-
-
49149097342
-
Fabrication and characterisation of CMOS compatible silicon nanowire biosensor
-
Kan G.B., Park J.M., Kim S.G., Koo J.G., Park J.H., Sohn Y.S., and Kim Y.T. Fabrication and characterisation of CMOS compatible silicon nanowire biosensor. Electron. Lett. 44 (2008) 953-955
-
(2008)
Electron. Lett.
, vol.44
, pp. 953-955
-
-
Kan, G.B.1
Park, J.M.2
Kim, S.G.3
Koo, J.G.4
Park, J.H.5
Sohn, Y.S.6
Kim, Y.T.7
|