메뉴 건너뛰기




Volumn 10, Issue 1, 2009, Pages 21-26

Image-based drill templates for cervical pedicle screw placement: Laboratory investigation

Author keywords

Cervical spine; Drill template; Pedicle screw; Rapid prototype

Indexed keywords

ARTICLE; CERVICAL SPINAL CORD; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; HUMAN; HUMAN TISSUE; PEDICLE SCREW; BONE SCREW; CADAVER; CERVICAL SPINE; INSTRUMENTATION; METHODOLOGY; RADIOGRAPHY; SPINE FUSION; SURGICAL INSTRUMENT; THREE DIMENSIONAL IMAGING;

EID: 61549124125     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2008.9.SPI08229     Document Type: Article
Times cited : (48)

References (42)
  • 1
    • 0032950970 scopus 로고    scopus 로고
    • One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems
    • Abumi K, Kaneda K, Shono Y, Fujiya M: One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg 90:19-26, 1999 (Pubitemid 29037129)
    • (1999) Journal of Neurosurgery , vol.90 , Issue.1 SUPPL. , pp. 19-26
    • Abumi, K.1    Kaneda, K.2    Shono, Y.3    Fujiya, M.4
  • 2
    • 0034655412 scopus 로고    scopus 로고
    • Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
    • DOI 10.1097/00007632-200004150-00011
    • Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K: Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962-969, 2000 (Pubitemid 30235856)
    • (2000) Spine , vol.25 , Issue.8 , pp. 962-969
    • Abumi, K.1    Shono, Y.2    Ito, M.3    Taneichi, H.4    Kotani, Y.5    Kaneda, K.6
  • 3
    • 0033958049 scopus 로고    scopus 로고
    • Indirect posterior reduction and fusion of the traumatic herniated disc by using a cervical pedicle screw system
    • Abumi K, Shono Y, Kotani Y, Kaneda K: Indirect posterior reduction and fusion of the traumatic herniated disc by using a cervical pedicle screw system. J Neurosurg 92:30-37, 2000 (Pubitemid 30020447)
    • (2000) Journal of Neurosurgery , vol.92 , Issue.1 SUPPL. , pp. 30-37
    • Abumi, K.1    Shono, Y.2    Kotani, Y.3    Kaneda, K.4
  • 4
    • 0032725360 scopus 로고    scopus 로고
    • Correction of cervical kyphosis using pedicle screw fixation systems
    • Abumi K, Shono Y, Taneichi H, Ito M, Kaneda K: Correction of cervical kyphosis using pedicle screw fixation systems. Spine 24:2389-2396, 1999
    • (1999) Spine , vol.24 , pp. 2389-2396
    • Abumi, K.1    Shono, Y.2    Taneichi, H.3    Ito, M.4    Kaneda, K.5
  • 5
    • 1542378008 scopus 로고    scopus 로고
    • Biomechanical evaluation of cervical lateral mass fixation: A comparison of the Roy-Camille and Magerl screw techniques
    • Barrey C, Mertens P, Rumelhart C, Cotton F, Jund J, Perrin G: Biomechanical evaluation of cervical lateral mass fixation: a comparison of the Roy-Camille and Magerl screw techniques. J Neurosurg 100:268-276, 2004 (Pubitemid 38294989)
    • (2004) Journal of Neurosurgery , vol.100 , Issue.3 SUPPL. , pp. 268-276
    • Barrey, C.1    Mertens, P.2    Rumelhart, C.3    Cotton, F.4    Jund, J.5    Perrin, G.6
  • 7
    • 0038750566 scopus 로고    scopus 로고
    • Evaluation of registration methods used in frameless stereotactic surgery for the lumbar and cervical regions of the spine
    • Buchowski JM, Helm PA, Huckell CB, Riley LH III, Cohen DB, Ahn NU, et al: Evaluation of registration methods used in frameless stereotactic surgery for the lumbar and cervical regions of the spine. Am J Orthop 32:90-97, 2003
    • (2003) Am J Orthop , vol.32 , pp. 90-97
    • Buchowski, J.M.1    Helm, P.A.2    Huckell, C.B.3    Riley III, L.H.4    Cohen, D.B.5    Ahn, N.U.6
  • 8
    • 29444440003 scopus 로고    scopus 로고
    • Biomodeling as an aid to spinal instrumentation
    • DOI 10.1097/01.brs.0000190886.56895.3d
    • D'Urso PS, Williamson OD, Thompson RG: Biomodeling as an aid to spinal instrumentation. Spine 30:2841-2845, 2005 (Pubitemid 43011052)
    • (2005) Spine , vol.30 , Issue.24 , pp. 2841-2845
    • D'Urso, P.S.1    Williamson, O.D.2    Thompson, R.G.3
  • 9
    • 0031022259 scopus 로고    scopus 로고
    • Morphometric evaluation of lower cervical pedicle and its projection
    • DOI 10.1097/00007632-199701010-00001
    • Ebraheim NA, Xu R, Knight T, Yeasting RA: Morphometric evaluation of lower cervical pedicle and its projection. Spine 22:1-6, 1997 (Pubitemid 27044829)
    • (1997) Spine , vol.22 , Issue.1 , pp. 1-6
    • Ebraheim, N.A.1    Xu, R.2    Knight, T.3    Yeasting, R.A.4
  • 10
    • 0035875841 scopus 로고    scopus 로고
    • Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2
    • DOI 10.1097/00007632-200106150-00017
    • Goffin J, Van Brussel K, Martens K, Vander Sloten J, Van Audekercke R, Smet MH: Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2. Spine 26:1343-1347, 2001 (Pubitemid 32552511)
    • (2001) Spine , vol.26 , Issue.12 , pp. 1343-1347
    • Goffin, J.1    Van Brussel, K.2    Martens, K.3    Vander Sloten, J.4    Van Audekercke, R.5    Smet, M.-H.6
  • 11
    • 33645499877 scopus 로고    scopus 로고
    • Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy
    • Holly LT, Foley KT: Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536-541, 2006
    • (2006) Spine , vol.31 , pp. 536-541
    • Holly, L.T.1    Foley, K.T.2
  • 13
    • 0031010622 scopus 로고    scopus 로고
    • Cervical pedicle screws versus lateral mass screws: Anatomic feasibility and biomechanical comparison
    • DOI 10.1097/00007632-199705010-00009
    • Jones EL, Heller JG, Silcox DH, Hutton WC: Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine 22:977-982, 1997 (Pubitemid 27203488)
    • (1997) Spine , vol.22 , Issue.9 , pp. 977-982
    • Jones, E.L.1    Heller, J.G.2    Silcox, D.H.3    Hutton, W.C.4
  • 14
    • 0034466242 scopus 로고    scopus 로고
    • Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
    • DOI 10.1097/00002517-200006000-00004
    • Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K: Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218-224, 2000 (Pubitemid 32201546)
    • (2000) Journal of Spinal Disorders , vol.13 , Issue.3 , pp. 218-224
    • Kamimura, M.1    Ebara, S.2    Itoh, H.3    Tateiwa, Y.4    Kinoshita, T.5    Takaoka, K.6
  • 15
    • 0030965497 scopus 로고    scopus 로고
    • Morphologic characteristics of human cervical pedicles
    • DOI 10.1097/00007632-199703010-00005
    • Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr: Morphologic characteristics of human cervical pedicles. Spine 22:493-500, 1997 (Pubitemid 27118518)
    • (1997) Spine , vol.22 , Issue.5 , pp. 493-500
    • Karaikovic, E.E.1    Daubs, M.D.2    Madsen, R.W.3    Gaines Jr., R.W.4
  • 16
    • 0033797290 scopus 로고    scopus 로고
    • Surgical anatomy of the cervical pedicles: Landmarks for posterior cervical pedicle entrance localization
    • Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr: Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13:63-72, 2000
    • (2000) J Spinal Disord , vol.13 , pp. 63-72
    • Karaikovic, E.E.1    Kunakornsawat, S.2    Daubs, M.D.3    Madsen, T.W.4    Gaines Jr., R.W.5
  • 17
    • 0035890086 scopus 로고    scopus 로고
    • Accuracy of cervical pedicle screw placement using the funnel technique
    • DOI 10.1097/00007632-200111150-00012
    • Karaikovic EE, Yingsakmongkol W, Gaines RW Jr: Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26:2456-2462, 2001 (Pubitemid 33065056)
    • (2001) Spine , vol.26 , Issue.22 , pp. 2456-2462
    • Karaikovic, E.E.1    Yingsakmongkol, W.2    Gaines Jr., R.W.3
  • 18
    • 33644658640 scopus 로고    scopus 로고
    • Complications of transpedicular screw fixation in the cervical spine
    • DOI 10.1007/s00586-004-0861-7
    • Kast E, Mohr K, Richter HP, Borm W: Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 15:327-334, 2006 (Pubitemid 43327667)
    • (2006) European Spine Journal , vol.15 , Issue.3 , pp. 327-334
    • Kast, E.1    Mohr, K.2    Richter, H.-P.3    Borm, W.4
  • 19
    • 0242662355 scopus 로고    scopus 로고
    • The Accuracy of Computed Tomography in Assessing Cervical Pedicle Screw Placement
    • DOI 10.1097/01.BRS.0000090830.94641.AE
    • Kim HS, Heller JG, Hudgins PA, Fountain JA: The accuracy of computed tomography in assessing cervical pedicle screw placement. Spine 28:2441-2446, 2003 (Pubitemid 37386222)
    • (2003) Spine , vol.28 , Issue.21 , pp. 2441-2446
    • Kim, H.-S.1    Heller, J.G.2    Hudgins, P.A.3    Fountain, J.A.4
  • 20
    • 0142120120 scopus 로고    scopus 로고
    • Improved accuracy of computer-assisted cervical pedicle screw insertion
    • Kotani Y, Abumi K, Ito M, Minami A: Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99:257-263, 2003
    • (2003) J Neurosurg , vol.99 , pp. 257-263
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Minami, A.4
  • 21
    • 4444332803 scopus 로고    scopus 로고
    • Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine
    • DOI 10.1097/01.brs.0000137287.67388.0b
    • Kothe R, Ruther W, Schneider E, Linke B: Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine 29:1869-1875, 2004 (Pubitemid 39181043)
    • (2004) Spine , vol.29 , Issue.17 , pp. 1869-1875
    • Kothe, R.1    Ruther, W.2    Schneider, E.3    Linke, B.4
  • 22
    • 39049192490 scopus 로고    scopus 로고
    • Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique
    • Chinese
    • Liu YJ, Tian W, Liu B, Li Q, Hu L, Li ZY, et al: [Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique.] Zhonghua Wai Ke Za Zhi 43:1328-1330, 2005 (Chinese)
    • (2005) Zhonghua Wai Ke Za Zhi , vol.43 , pp. 1328-1330
    • Liu, Y.J.1    Tian, W.2    Liu, B.3    Li, Q.4    Hu, L.5    Li, Z.Y.6
  • 23
    • 0034667343 scopus 로고    scopus 로고
    • Cervical pedicle screws: Comparative accuracy of two insertion techniques
    • Ludwig SC, Kowalski JM, Edwards CC II, Heller JG: Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine 25:2675-2681, 2000
    • (2000) Spine , vol.25 , pp. 2675-2681
    • Ludwig, S.C.1    Kowalski, J.M.2    Edwards II, C.C.3    Heller, J.G.4
  • 24
    • 0033925472 scopus 로고    scopus 로고
    • Placement of pedicle screws in the human cadaveric cervical spine: Comparative accuracy of three techniques
    • DOI 10.1097/00007632-200007010-00009
    • Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ: Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25:1655-1667, 2000 (Pubitemid 30460467)
    • (2000) Spine , vol.25 , Issue.13 , pp. 1655-1667
    • Ludwig, S.C.1    Kramer, D.L.2    Balderston, R.A.3    Vaccaro, A.R.4    Foley, K.F.5    Albert, T.J.6
  • 26
    • 0242487967 scopus 로고    scopus 로고
    • Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
    • DOI 10.1007/s00586-003-0549-4
    • Mac-Thiong JM, Labelle H, Rooze M, Feipel V, Aubin CE: Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine. Eur Spine J 12:542-547, 2003 (Pubitemid 37409957)
    • (2003) European Spine Journal , vol.12 , Issue.5 , pp. 542-547
    • Mac-Thiong, J.-M.1    Labelle, H.2    Rooze, M.3    Feipel, V.4    Aubin, C.-E.5
  • 27
    • 18644366161 scopus 로고    scopus 로고
    • Design of cervical pedicle locator and three-dimensional location of cervical pedicle
    • DOI 10.1097/01.brs.0000161011.08086.5b
    • Mao GP, Zhao JN, Wang YR, Li JS, Chen YX, Wu SJ, et al: Design of cervical pedicle locator and three-dimensional location of cervical pedicle. Spine 30:1045-1050, 2005 (Pubitemid 40663911)
    • (2005) Spine , vol.30 , Issue.9 , pp. 1045-1050
    • Mao, G.-P.1    Zhao, J.-N.2    Wang, Y.-R.3    Li, J.-S.4    Chen, Y.-X.5    Wu, S.-J.6    Bao, N.-R.7
  • 28
    • 0029848159 scopus 로고    scopus 로고
    • Anatomic consideration of transpedicular screw placement in the cervical spine: An analysis of two approaches
    • DOI 10.1097/00007632-199610150-00003
    • Miller RM, Ebraheim NA, Xu R, Yeasting RA: Anatomic consideration of transpedicular screw placement in the cervical spine. An analysis of two approaches. Spine 21:2317-2322, 1996 (Pubitemid 26362112)
    • (1996) Spine , vol.21 , Issue.20 , pp. 2317-2322
    • Miller, R.M.1    Ebraheim, N.A.2    Xu, R.3    Yeasting, R.A.4
  • 31
    • 33846421082 scopus 로고    scopus 로고
    • Cervical pedicle screw placement: Feasibility and accuracy of two new insertion techniques based on morphometric data
    • DOI 10.1007/s00586-006-0104-1
    • Reinhold M, Magerl F, Rieger M, Blauth M: Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data. Eur Spine J 16:47-56, 2006 (Pubitemid 46147227)
    • (2007) European Spine Journal , vol.16 , Issue.1 , pp. 47-56
    • Reinhold, M.1    Magerl, F.2    Rieger, M.3    Blauth, M.4
  • 32
    • 33645524938 scopus 로고    scopus 로고
    • A comparison of pedicle and lateral mass screw construct stiffnesses at the cervicothoracic junction: A biomechanical study
    • Rhee JM, Kraiwattanapong C, Hutton WC: A comparison of pedicle and lateral mass screw construct stiffnesses at the cervicothoracic junction: a biomechanical study. Spine 30:E636-E640, 2005
    • (2005) Spine , vol.30
    • Rhee, J.M.1    Kraiwattanapong, C.2    Hutton, W.C.3
  • 33
    • 0001908749 scopus 로고    scopus 로고
    • Computer-assisted surgery in posterior instrumentation of the cervical spine: An in-vitro feasibility study
    • Richter M, Amiot LP, Neller S, Kluger P, Puhl W: Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study. Eur Spine J 9 (1 Suppl):S65-S70, 2000
    • (2000) Eur Spine J , vol.9 , Issue.1 SUPPL.
    • Richter, M.1    Amiot, L.P.2    Neller, S.3    Kluger, P.4    Puhl, W.5
  • 34
    • 27144527301 scopus 로고    scopus 로고
    • Cervical pedicle screws: Conventional versus computer-assisted placement of cannulated screws
    • DOI 10.1097/01.brs.0000182275.31425.cd
    • Richter M, Cakir B, Schmidt R: Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30:2280-2287, 2005 (Pubitemid 41504897)
    • (2005) Spine , vol.30 , Issue.20 , pp. 2280-2287
    • Richter, M.1    Cakir, B.2    Schmidt, R.3
  • 35
    • 1442277695 scopus 로고    scopus 로고
    • Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
    • DOI 10.1007/s00586-003-0604-1
    • Richter M, Mattes T, Cakir B: Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J 13:50-60, 2004 (Pubitemid 38292037)
    • (2004) European Spine Journal , vol.13 , Issue.1 , pp. 50-59
    • Richter, M.1    Mattes, T.2    Cakir, B.3
  • 36
    • 14844347683 scopus 로고    scopus 로고
    • Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle
    • DOI 10.1097/01.brs.0000144404.68486.85
    • Sakamoto T, Neo M, Nakamura T: Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine 29:2510-2515, 2004 (Pubitemid 40353269)
    • (2004) Spine , vol.29 , Issue.22 , pp. 2510-2514
    • Sakamoto, T.1    Neo, M.2    Nakamura, T.3
  • 37
    • 21344457217 scopus 로고    scopus 로고
    • Effect of constrained posterior screw and rod systems for primary stability: Biomechanical in vitro comparison of various instrumentations in a single-level corpectomy model
    • DOI 10.1007/s00586-004-0763-8
    • Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M: Effect of constrained posterior screw and rod systems for primary stability: biomechanical in vitro comparison of various instrumentations in a single-level corpectomy model. Eur Spine J 14:372-380, 2005 (Pubitemid 40909609)
    • (2005) European Spine Journal , vol.14 , Issue.4 , pp. 372-380
    • Schmidt, R.1    Wilke, H.-J.2    Claes, L.3    Puhl, W.4    Richter, M.5
  • 38
    • 0041472666 scopus 로고    scopus 로고
    • Pedicle screws enhance primary stability in multilevel cervical corpectomies: Biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instumentations
    • DOI 10.1097/01.BRS.0000083287.23521.48
    • Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M: Pedicle screws enhance primary stability in multilevel cervical corpectomies: biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instumentations. Spine 28:1821-1828, 2003 (Pubitemid 37012758)
    • (2003) Spine , vol.28 , Issue.16 , pp. 1821-1828
    • Schmidt, R.1    Wilke, H.-J.2    Claes, L.3    Puhl, W.4    Richter, M.5
  • 39
    • 32644474179 scopus 로고    scopus 로고
    • Posterior cervical lateral mass screw fixation: Analysis of 1026 consecutive screws in 143 patients
    • DOI 10.1097/01.bsd.0000166640.23448.09, PII 0002472020050800000001
    • Sekhon LH: Posterior cervical lateral mass screw fixation: analysis of 1026 consecutive screws in 143 patients. J Spinal Disord Tech 18:297-303, 2005 (Pubitemid 44378144)
    • (2005) Journal of Spinal Disorders and Techniques , vol.18 , Issue.4 , pp. 297-303
    • Sekhon, L.H.S.1
  • 40
    • 0033825575 scopus 로고    scopus 로고
    • The anatomic variability of human cervical pedicles: Considerations for transpedicular screw fixation in the middle and lower cervical spine
    • Shin EK, Panjabi MM, Chen NC, Wang JL: The anatomic variability of human cervical pedicles: considerations for transpedicular screw fixation in the middle and lower cervical spine. Eur Spine J 9:61-66, 2000
    • (2000) Eur Spine J , vol.9 , pp. 61-66
    • Shin, E.K.1    Panjabi, M.M.2    Chen, N.C.3    Wang, J.L.4
  • 41
    • 0033759317 scopus 로고    scopus 로고
    • Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures
    • Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Caglar S, et al: Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47:1162-1169, 2000
    • (2000) Neurosurgery , vol.47 , pp. 1162-1169
    • Ugur, H.C.1    Attar, A.2    Uz, A.3    Tekdemir, I.4    Egemen, N.5    Caglar, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.