Volumn 31, Issue 5, 2006, Pages 536-540

Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy

Author keywords

Accuracy; Cervical; Fluoroscopy; Instrumentation; Navigation; Three dimensional

Indexed keywords

ACCURACY; ARTICLE; AUTOMATION; CERVICAL SPINE; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; FLUOROSCOPY; HUMAN; HUMAN TISSUE; INCISION; LIGHT EMITTING DIODE; MINIMALLY INVASIVE SURGERY; PEDICLE SCREW; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; BONE SCREW; FEASIBILITY STUDY; IMPLANTATION; METHODOLOGY; REPRODUCIBILITY; SPINE DISEASE;

EID: 33645499877     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/01.brs.0000201297.83920.a1     Document Type: Article
Times cited : (88)

References (17)
  • 1
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular fixation technique
    • Madawi AA, Casey AT, Solanki GK, et al. Radiological and anatomical evaluation of the atlantoaxial transarticular fixation technique. J Neurosurg 1997;86:961-8.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.2    Solanki, G.K.3
  • 2
    • 0034659356 scopus 로고    scopus 로고
    • Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws
    • Mandel IM, Kambach BJ, Petersilge CA, et al. Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine 2000;25:1542-7.
    • (2000) Spine , vol.25 , pp. 1542-1547
    • Mandel, I.M.1    Kambach, B.J.2    Petersilge, C.A.3
  • 3
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickman CA, Sonntag VKH. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 1996;85: 221-4.
    • (1996) J Neurosurg , vol.85 , pp. 221-224
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.H.3
  • 4
    • 0033561455 scopus 로고    scopus 로고
    • Image-guided anterior cervical corpectomy: A feasibility study
    • Albert TJ, Klein GR, Vaccaro AR. Image-guided anterior cervical corpectomy: a feasibility study. Spine 1999;24:826-30.
    • (1999) Spine , vol.24 , pp. 826-830
    • Albert, T.J.1    Klein, G.R.2    Vaccaro, A.R.3
  • 5
    • 0034866583 scopus 로고    scopus 로고
    • Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
    • Spine 1
    • Bloch O, Holly LT, Park J, et al. Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement. J Neurosurg 2001 (Spine 1); 95:74-9.
    • (2001) J Neurosurg , vol.95 , pp. 74-79
    • Bloch, O.1    Holly, L.T.2    Park, J.3
  • 6
    • 0033395291 scopus 로고    scopus 로고
    • Frameless stereotaxy and anterior cervical surgery
    • Bolger C, Wigfield C, Melkent T, et al. Frameless stereotaxy and anterior cervical surgery. Comput Aided Surg 1999;4:322-27.
    • (1999) Comput Aided Surg , vol.4 , pp. 322-327
    • Bolger, C.1    Wigfield, C.2    Melkent, T.3
  • 7
    • 0002669361 scopus 로고    scopus 로고
    • Frameless stereotactic guidance of cervical spine lateral mass screw placement
    • Nolte LP, Gans R, eds. Bern, Switzerland: Hogrefe and Huber
    • Foley KT, Smith KR, Smith MM. Frameless stereotactic guidance of cervical spine lateral mass screw placement. In: Nolte LP, Gans R, eds. Computer Assisted Orthopaedic Surgery (CAOS). Bern, Switzerland: Hogrefe and Huber, 1999:89-98.
    • (1999) Computer Assisted Orthopaedic Surgery (CAOS) , pp. 89-98
    • Foley, K.T.1    Smith, K.R.2    Smith, M.M.3
  • 8
    • 0006026676 scopus 로고    scopus 로고
    • Frameless stereotactic guidance of C1-2 transarticular screw placement: Clinical experience
    • Foley KT, Smith MM. Frameless stereotactic guidance of C1-2 transarticular screw placement: clinical experience [Abstract]. J Neurosurg 1997;86:360A.
    • (1997) J Neurosurg , vol.86
    • Foley, K.T.1    Smith, M.M.2
  • 9
    • 0035489950 scopus 로고    scopus 로고
    • Frameless stereotaxy for anterior spinal procedures
    • Holly LT, Bloch O, Obasi C, et al. Frameless stereotaxy for anterior spinal procedures. J Neurosurg (Spine 2) 2001;95:196-201.
    • (2001) J Neurosurg (Spine 2) , vol.95 , pp. 196-201
    • Holly, L.T.1    Bloch, O.2    Obasi, C.3
  • 10
    • 0030922136 scopus 로고    scopus 로고
    • Frameless stereotactic guidance for surgery of the upper cervical spine
    • Welch WC, Subach BR, Pollack IF, et al. Frameless stereotactic guidance for surgery of the upper cervical spine. Neurosurgery 1997;40:958-64.
    • (1997) Neurosurgery , vol.40 , pp. 958-964
    • Welch, W.C.1    Subach, B.R.2    Pollack, I.F.3
  • 11
    • 0035865652 scopus 로고    scopus 로고
    • Virtual fluoroscopy: Computer-assisted fluoroscopic navigation
    • Foley KT, Simon DA, Rampersaud YA. Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 2001;26:347-51.
    • (2001) Spine , vol.26 , pp. 347-351
    • Foley, K.T.1    Simon, D.A.2    Rampersaud, Y.A.3
  • 12
    • 0042568676 scopus 로고    scopus 로고
    • Intraoperative spinal navigation
    • Holly LT, Foley KT. Intraoperative spinal navigation. Spine 2003;28(suppl): 54-61.
    • (2003) Spine , vol.28 , Issue.SUPPL. , pp. 54-61
    • Holly, L.T.1    Foley, K.T.2
  • 13
    • 0025952072 scopus 로고
    • Atlantoaxial fusion with transarticular screw fixation
    • Grob D, Jeanneret B, Aebi M, et al. Atlantoaxial fusion with transarticular screw fixation. J Bone Joint Surg Br 1991;73:972-6.
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 972-976
    • Grob, D.1    Jeanneret, B.2    Aebi, M.3
  • 14
    • 0030062112 scopus 로고    scopus 로고
    • Posterior cervical arthrodesis and stabilization with a lateral mass plate: Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications
    • Graham AW, Swank ML, Kinard RE, et al. Posterior cervical arthrodesis and stabilization with a lateral mass plate: clinical and computed tomographic evaluation of lateral mass screw placement and associated complications. Spine 1996;21:323-9.
    • (1996) Spine , vol.21 , pp. 323-329
    • Graham, A.W.1    Swank, M.L.2    Kinard, R.E.3
  • 15
    • 0028882788 scopus 로고
    • Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine
    • Heller JG, Carlson GD, Abitol JJ, et al. Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine. Spine 1995;20:2442-8.
    • (1995) Spine , vol.20 , pp. 2442-2448
    • Heller, J.G.1    Carlson, G.D.2    Abitol, J.J.3
  • 16
    • 0142120104 scopus 로고    scopus 로고
    • Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement
    • Holly LT, Foley KT. Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement [Technical note]. J Neurosurg 2003; 99(suppl 3):324-9.
    • (2003) J Neurosurg , vol.99 , Issue.3 SUPPL. , pp. 324-329
    • Holly, L.T.1    Foley, K.T.2
  • 17
    • 0036288337 scopus 로고    scopus 로고
    • Percutaneous pedicle screw fixation of the lumbar spine: Preliminary clinical results
    • Spine 1
    • Foley KT, Gupta SK. Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results. J Neurosurg 2002;97(Spine 1):7-12.
    • (2002) J Neurosurg , vol.97 , pp. 7-12
    • Foley, K.T.1    Gupta, S.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.