메뉴 건너뛰기




Volumn 18, Issue 4, 2005, Pages 297-303

Posterior cervical lateral mass screw fixation: Analysis of 1026 consecutive screws in 143 patients

Author keywords

Cervical; Lateral mass; Screw; Surgery; Vertebral artery

Indexed keywords

ADULT; AGED; ARTERY INJURY; BONE PLATE; BONE SCREW; CERVICAL SPINE; CERVICAL SPINE INJURY; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FOLLOW UP; HUMAN; IMPLANT; MAJOR CLINICAL STUDY; MALE; NERVE ROOT INJURY; ORTHOPEDIC EQUIPMENT; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; REVIEW; RHEUMATOID ARTHRITIS; SPINE INSTABILITY; SPINE STABILIZATION; SPINE SURGERY; SPINE TUMOR; SURGICAL TECHNIQUE; TREATMENT FAILURE; TREATMENT INDICATION; TREATMENT OUTCOME; VERTEBRAL ARTERY; ADOLESCENT; ARTICLE; CHILD; MIDDLE AGED; RADIOGRAPHY;

EID: 32644474179     PISSN: 15360652     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.bsd.0000166640.23448.09     Document Type: Review
Times cited : (95)

References (29)
  • 1
    • 0003111805 scopus 로고
    • Early management of spinal injuries
    • McKibben B, ed. Edinburgh: Churchill-Livingstone
    • Roy-Camille R, Gaillant G, Bertreaux D. Early management of spinal injuries. In: McKibben B, ed. Recent Advances in Orthopedics. Edinburgh: Churchill-Livingstone; 1979:57-87.
    • (1979) Recent Advances in Orthopedics , pp. 57-87
    • Roy-Camille, R.1    Gaillant, G.2    Bertreaux, D.3
  • 2
    • 0031032221 scopus 로고    scopus 로고
    • Posterior cervical fixation for fracture and degenerative disc disease
    • An HS, Coppes MA. Posterior cervical fixation for fracture and degenerative disc disease. Clin Orthop. 1997;335:101-111.
    • (1997) Clin Orthop , vol.335 , pp. 101-111
    • An, H.S.1    Coppes, M.A.2
  • 3
    • 0024318012 scopus 로고
    • Fixation of fractures of the lower cervical spine using methylmethacrylate and wire: Technique and results in 99 patients
    • Branch CL Jr, Kelly DL Jr, Davis CH Jr, et al. Fixation of fractures of the lower cervical spine using methylmethacrylate and wire: Technique and results in 99 patients. Neurosurgery. 1989;25:503-512.
    • (1989) Neurosurgery , vol.25 , pp. 503-512
    • Branch Jr., C.L.1    Kelly Jr., D.L.2    Davis Jr., C.H.3
  • 4
    • 0028113856 scopus 로고
    • Evaluation of spinal laminar fixation by a new, flexible stainless steel cable (Sof'wire): Early results
    • Crockard A. Evaluation of spinal laminar fixation by a new, flexible stainless steel cable (Sof'wire): Early results. Neurosurgery. 1994;35:892-898.
    • (1994) Neurosurgery , vol.35 , pp. 892-898
    • Crockard, A.1
  • 5
    • 0024325510 scopus 로고
    • Titanium wire internal fixation for stabilization of injury of the cervical spine: Clinical results and postoperative magnetic resonance imaging of the spinal cord
    • Geisler FH, Mirvis SE, Zrebeet H, et al. Titanium wire internal fixation for stabilization of injury of the cervical spine: Clinical results and postoperative magnetic resonance imaging of the spinal cord. Neurosurgery. 1989;25:356-362.
    • (1989) Neurosurgery , vol.25 , pp. 356-362
    • Geisler, F.H.1    Mirvis, S.E.2    Zrebeet, H.3
  • 6
    • 0023756419 scopus 로고
    • Use of titanium wire in cervical spine fixation as a means to reduce MR artifacts
    • Mirvis SE, Geisler F, Joslyn JN, et al. Use of titanium wire in cervical spine fixation as a means to reduce MR artifacts. AJNR Am J Neuroradiol. 1988;9:1229-1231.
    • (1988) AJNR Am J Neuroradiol , vol.9 , pp. 1229-1231
    • Mirvis, S.E.1    Geisler, F.2    Joslyn, J.N.3
  • 7
    • 0242382073 scopus 로고    scopus 로고
    • Lateral mass screw-rod fixation of the cervical spine: A prospective clinical series with 1-year follow-up
    • Deen HG, Birch BD, Wharen RE, et al. Lateral mass screw-rod fixation of the cervical spine: A prospective clinical series with 1-year follow-up. Spine J. 2003;3:489-495.
    • (2003) Spine J , vol.3 , pp. 489-495
    • Deen, H.G.1    Birch, B.D.2    Wharen, R.E.3
  • 8
    • 0030062112 scopus 로고    scopus 로고
    • Posterior cervical arthrodesis and stabilization with a lateral mass plate. Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications
    • Graham AW, Swank ML, Kinard RE, et al. Posterior cervical arthrodesis and stabilization with a lateral mass plate. Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications. Spine. 1996;21:323-329.
    • (1996) Spine , vol.21 , pp. 323-329
    • Graham, A.W.1    Swank, M.L.2    Kinard, R.E.3
  • 9
    • 0033015463 scopus 로고    scopus 로고
    • Posterior cervical arthrodesis and stabilization: An early report using a novel lateral mass screw and rod technique
    • Horgan MA, Kellogg JX, Chesnut RM. Posterior cervical arthrodesis and stabilization: an early report using a novel lateral mass screw and rod technique. Neurosurgery. 1999;44:1267-1271.
    • (1999) Neurosurgery , vol.44 , pp. 1267-1271
    • Horgan, M.A.1    Kellogg, J.X.2    Chesnut, R.M.3
  • 10
    • 0034329881 scopus 로고    scopus 로고
    • Techniques and pitfalls of cervical lateral mass plate fixation
    • Muffoletto AJ, Hadjipavlou AG, Jensen RE, et al. Techniques and pitfalls of cervical lateral mass plate fixation. Am J Orthop. 2000;29:897-903.
    • (2000) Am J Orthop , vol.29 , pp. 897-903
    • Muffoletto, A.J.1    Hadjipavlou, A.G.2    Jensen, R.E.3
  • 11
    • 0025979504 scopus 로고
    • Posterior cervical arthrodesis with AO reconstruction plates and bone graft
    • Anderson PA, Henley MB, Grady MS, et al. Posterior cervical arthrodesis with AO reconstruction plates and bone graft. Spine. 1991;16:S72-S79.
    • (1991) Spine , vol.16
    • Anderson, P.A.1    Henley, M.B.2    Grady, M.S.3
  • 12
    • 0026727307 scopus 로고
    • Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine
    • Errico T, Uhl R, Cooper P, et al. Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine. J Spinal Disord. 1992;5:459-463.
    • (1992) J Spinal Disord , vol.5 , pp. 459-463
    • Errico, T.1    Uhl, R.2    Cooper, P.3
  • 13
    • 0032701121 scopus 로고    scopus 로고
    • Outcome of 51 cases of unilateral locked cervical facets: Interspinous braided cable for lateral mass plate fusion compared with interspinous wire and facet wiring with iliac crest
    • Shapiro S, Snyder W, Kaufman K, et al. Outcome of 51 cases of unilateral locked cervical facets: Interspinous braided cable for lateral mass plate fusion compared with interspinous wire and facet wiring with iliac crest. J Neurosurg. 1999;91:19-24.
    • (1999) J Neurosurg , vol.91 , pp. 19-24
    • Shapiro, S.1    Snyder, W.2    Kaufman, K.3
  • 14
    • 0035057857 scopus 로고    scopus 로고
    • Internal fixation on the lower cervical spine - Biomechanics and clinical practice of procedures and implants
    • Ulrich C, Arand M, Nothwang J. Internal fixation on the lower cervical spine - Biomechanics and clinical practice of procedures and implants. Eur Spine J. 2001;10:88-100.
    • (2001) Eur Spine J , vol.10 , pp. 88-100
    • Ulrich, C.1    Arand, M.2    Nothwang, J.3
  • 15
    • 0031809357 scopus 로고    scopus 로고
    • Modified Magerl technique of lateral mass screw placement in the lower cervical spine: An anatomic study
    • Xu R, Ebraheim NA, Klausner T, et al. Modified Magerl technique of lateral mass screw placement in the lower cervical spine: An anatomic study. J Spinal Disord. 1998;11:237-240.
    • (1998) J Spinal Disord , vol.11 , pp. 237-240
    • Xu, R.1    Ebraheim, N.A.2    Klausner, T.3
  • 16
    • 0033214753 scopus 로고    scopus 로고
    • The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques
    • Xu R, Haman SP, Ebraheim NA, et al. The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques. Spine. 1999;24:2057-2061.
    • (1999) Spine , vol.24 , pp. 2057-2061
    • Xu, R.1    Haman, S.P.2    Ebraheim, N.A.3
  • 17
    • 0032618546 scopus 로고    scopus 로고
    • Anatomic relationship of the cervical nerves to the lateral masses
    • Ebraheim NA, Xu R, Stanescu S, et al. Anatomic relationship of the cervical nerves to the lateral masses. Am J Orthop. 1999;28:39-42.
    • (1999) Am J Orthop , vol.28 , pp. 39-42
    • Ebraheim, N.A.1    Xu, R.2    Stanescu, S.3
  • 18
    • 0029927045 scopus 로고    scopus 로고
    • The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation
    • Ebraheim NA, Xu R, Yeasting RA. The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation. Spine. 1996;21:1291-1295.
    • (1996) Spine , vol.21 , pp. 1291-1295
    • Ebraheim, N.A.1    Xu, R.2    Yeasting, R.A.3
  • 19
    • 0026044673 scopus 로고
    • Anatomic considerations for plate-screw fixation of the cervical spine
    • An HS, Gordin R, Renner K. Anatomic considerations for plate-screw fixation of the cervical spine. Spine. 1991;16:S548-S551.
    • (1991) Spine , vol.16
    • An, H.S.1    Gordin, R.2    Renner, K.3
  • 20
    • 0025948961 scopus 로고
    • Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine
    • Heller JG, Carlson GD, Abitbol JJ, et al. Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine. Spine. 1991;16:S552-S557.
    • (1991) Spine , vol.16
    • Heller, J.G.1    Carlson, G.D.2    Abitbol, J.J.3
  • 21
    • 0028882788 scopus 로고
    • Complications of posterior cervical plating
    • Heller JG, Silcox DH, Sutterlin CE. Complications of posterior cervical plating. Spine. 1995;20:2442-2448.
    • (1995) Spine , vol.20 , pp. 2442-2448
    • Heller, J.G.1    Silcox, D.H.2    Sutterlin, C.E.3
  • 22
    • 0029004460 scopus 로고
    • Quadrant anatomy of the articular pillars (lateral cervical mass) of the cervical spine
    • Pait TG, McAllister PV, Kaufman HH. Quadrant anatomy of the articular pillars (lateral cervical mass) of the cervical spine. J Neurosurg. 1995;82:1011-1014.
    • (1995) J Neurosurg , vol.82 , pp. 1011-1014
    • Pait, T.G.1    McAllister, P.V.2    Kaufman, H.H.3
  • 23
    • 0026029275 scopus 로고
    • Posterior stabilization of the cervical spine with hook plates
    • Jeanneret B, Magerl F, Ward EH, et al. Posterior stabilization of the cervical spine with hook plates. Spine. 1991;16:S56-S63.
    • (1991) Spine , vol.16
    • Jeanneret, B.1    Magerl, F.2    Ward, E.H.3
  • 24
    • 0032518499 scopus 로고    scopus 로고
    • Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients
    • Wellman BJ, Follett KA, Traynelis VC. Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients. Spine. 1998;23:193-200.
    • (1998) Spine , vol.23 , pp. 193-200
    • Wellman, B.J.1    Follett, K.A.2    Traynelis, V.C.3
  • 25
    • 0029791895 scopus 로고    scopus 로고
    • Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance
    • Heller JG, Estes BT, Zaouali M, et al. Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance. J Bone Joint Surg Am. 1996;78:1315-1321.
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1315-1321
    • Heller, J.G.1    Estes, B.T.2    Zaouali, M.3
  • 26
    • 0032733596 scopus 로고    scopus 로고
    • Characteristics of unicortical and bicortical lateral mass screws in the cervical spine
    • Seybold EA, Baker JA, Criscitiello AA, et al. Characteristics of unicortical and bicortical lateral mass screws in the cervical spine. Spine. 1999;24:2397-2403.
    • (1999) Spine , vol.24 , pp. 2397-2403
    • Seybold, E.A.1    Baker, J.A.2    Criscitiello, A.A.3
  • 27
    • 0031427940 scopus 로고    scopus 로고
    • Pedicle screw fixation for nontraumatic lesions of the cervical spine
    • Abumi K, Kaneda K. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine. 1997;22:1853-1863.
    • (1997) Spine , vol.22 , pp. 1853-1863
    • Abumi, K.1    Kaneda, K.2
  • 28
    • 0034655412 scopus 로고    scopus 로고
    • Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
    • Abumi K, Shono Y, Ito M, et al. Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine. 2000;25:962-969.
    • (2000) Spine , vol.25 , pp. 962-969
    • Abumi, K.1    Shono, Y.2    Ito, M.3
  • 29
    • 0033565624 scopus 로고    scopus 로고
    • Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems
    • Abumi K, Takada T, Shono Y, et al. Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems. Spine. 1999;24:1425-1434.
    • (1999) Spine , vol.24 , pp. 1425-1434
    • Abumi, K.1    Takada, T.2    Shono, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.