메뉴 건너뛰기




Volumn 100, Issue 3 SUPPL., 2004, Pages 268-276

Biomechanical evaluation of cervical lateral mass fixation: A comparison of the Roy-Camille and Magerl screw techniques

Author keywords

Biomechanical testing spinal fixation; Bone screw; Cervical spine; Lateral mass; Pullout strength

Indexed keywords

ADULT; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE MINERAL; BONE SCREW; CADAVER; CERVICAL SPINE; CLINICAL ARTICLE; CLINICAL PRACTICE; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; MAGERL SCREW TECHNIQUE; PRIORITY JOURNAL; ROY CAMILLE SCREW TECHNIQUE; SPINE STABILIZATION; SURGICAL TECHNIQUE;

EID: 1542378008     PISSN: 00223085     EISSN: None     Source Type: Journal    
DOI: 10.3171/spi.2004.100.3.0268     Document Type: Article
Times cited : (44)

References (37)
  • 1
    • 0032527483 scopus 로고    scopus 로고
    • Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology
    • Albert TJ, Klein GR, Joffe D, et al: Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology. Spine 23:1596-1599, 1998
    • (1998) Spine , vol.23 , pp. 1596-1599
    • Albert, T.J.1    Klein, G.R.2    Joffe, D.3
  • 2
    • 0030057482 scopus 로고    scopus 로고
    • Flexion failure of posterior cervical lateral mass screws. Influence of insertion technique and position
    • Choueka J, Spivak JM, Kummer FJ, et al: Flexion failure of posterior cervical lateral mass screws. Influence of insertion technique and position. Spine 21:462-468, 1996
    • (1996) Spine , vol.21 , pp. 462-468
    • Choueka, J.1    Spivak, J.M.2    Kummer, F.J.3
  • 3
    • 0024430945 scopus 로고
    • Biomechanical evaluation of cervical spinal stabilization methods in a human cadaveric model
    • Coe JD, Warden KE, Sutterlin CE, et al: Biomechanical evaluation of cervical spinal stabilization methods in a human cadaveric model. Spine 14:1122-1131, 1989
    • (1989) Spine , vol.14 , pp. 1122-1131
    • Coe, J.D.1    Warden, K.E.2    Sutterlin, C.E.3
  • 4
    • 0029744848 scopus 로고    scopus 로고
    • The Axis Fixation System for posterior instrumentation of the cervical spine
    • Cooper PR: The Axis Fixation System for posterior instrumentation of the cervical spine. Neurosurgery 39:612-614, 1996
    • (1996) Neurosurgery , vol.39 , pp. 612-614
    • Cooper, P.R.1
  • 6
    • 0026727307 scopus 로고
    • Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine
    • Errico T, Uhl R, Cooper P, et al: Pullout strength comparison of two methods of orienting screw insertion in the lateral masses of the bovine cervical spine. J Spinal Disord 5:459-463, 1992
    • (1992) J Spinal Disord , vol.5 , pp. 459-463
    • Errico, T.1    Uhl, R.2    Cooper, P.3
  • 8
    • 0031409653 scopus 로고    scopus 로고
    • Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy
    • Grubb MR, Currier BL, Stone J, et al: Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy. Spine 22:1948-1954, 1997
    • (1997) Spine , vol.22 , pp. 1948-1954
    • Grubb, M.R.1    Currier, B.L.2    Stone, J.3
  • 9
    • 0035890052 scopus 로고    scopus 로고
    • A comparison of three screw types for unicortical fixation of the lateral mass of the cervical spine
    • Harris BM, Hilibrand AS, Nien Y, et al: A comparison of three screw types for unicortical fixation of the lateral mass of the cervical spine. Spine 26:2427-2431, 2001
    • (2001) Spine , vol.26 , pp. 2427-2431
    • Harris, B.M.1    Hilibrand, A.S.2    Nien, Y.3
  • 10
    • 0025948961 scopus 로고
    • Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine
    • Heller JG, Carlson GD, Abitbol JJ, et al: Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine. Spine 16:S552-S557, 1991
    • (1991) Spine , vol.16
    • Heller, J.G.1    Carlson, G.D.2    Abitbol, J.J.3
  • 11
    • 0029791895 scopus 로고    scopus 로고
    • Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance
    • Heller JG, Estes BT, Zaouali M, et al: Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance. J Bone Joint Surg Am 78:1315-1321, 1996
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1315-1321
    • Heller, J.G.1    Estes, B.T.2    Zaouali, M.3
  • 12
    • 0028882788 scopus 로고
    • Complications of posterior cervical plating
    • Heller JG, Silcox DH, Sutterlin CE: Complications of posterior cervical plating. Spine 20:2442-2448, 1995
    • (1995) Spine , vol.20 , pp. 2442-2448
    • Heller, J.G.1    Silcox, D.H.2    Sutterlin, C.E.3
  • 13
    • 0026029275 scopus 로고
    • Posterior stabilization of the cervical spine with hook plates
    • Jeanneret B, Magerl F, Ward H, et al: Posterior stabilization of the cervical spine with hook plates. Spine 16: S56-S63, 1991
    • (1991) Spine , vol.16
    • Jeanneret, B.1    Magerl, F.2    Ward, H.3
  • 14
    • 0031010622 scopus 로고    scopus 로고
    • Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison
    • Jones EL, Heller JG, Silcox DH, et al: Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine 22:977-982, 1997
    • (1997) Spine , vol.22 , pp. 977-982
    • Jones, E.L.1    Heller, J.G.2    Silcox, D.H.3
  • 15
    • 0028001036 scopus 로고
    • Anatomical and morphometric studies in posterior cervical spinal screw-plate systems
    • Jonsson H Jr, Rauschning W: Anatomical and morphometric studies in posterior cervical spinal screw-plate systems. J Spinal Disord 7:429-438, 1994
    • (1994) J Spinal Disord , vol.7 , pp. 429-438
    • Jonsson Jr., H.1    Rauschning, W.2
  • 16
    • 0026611965 scopus 로고
    • A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: Design considerations and specifications
    • Kalender WA: A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: design considerations and specifications. Med Phys 19:583-586, 1992
    • (1992) Med Phys , vol.19 , pp. 583-586
    • Kalender, W.A.1
  • 17
    • 0034465557 scopus 로고    scopus 로고
    • Cervical transfacet versus lateral mass screws: A biomechanical comparison
    • Klekamp JW, Ugbo JL, Heller JG, et al: Cervical transfacet versus lateral mass screws: a biomechanical comparison. J Spinal Disord 13:515-518, 2000
    • (2000) J Spinal Disord , vol.13 , pp. 515-518
    • Klekamp, J.W.1    Ugbo, J.L.2    Heller, J.G.3
  • 18
    • 0028918045 scopus 로고
    • Strength of anterior vertebral screw fixation in relationship to bone mineral density
    • Lim TH, An H, Evanich C, et al: Strength of anterior vertebral screw fixation in relationship to bone mineral density. J Spinal Disord 8:121-125, 1995
    • (1995) J Spinal Disord , vol.8 , pp. 121-125
    • Lim, T.H.1    An, H.2    Evanich, C.3
  • 19
    • 0034148872 scopus 로고    scopus 로고
    • Posterior lateral mass plate fixation of the cervical spine
    • Lindsey RW, Miclau T: Posterior lateral mass plate fixation of the cervical spine. J South Orthop Assoc 9:36-42, 2000
    • (2000) J South Orthop Assoc , vol.9 , pp. 36-42
    • Lindsey, R.W.1    Miclau, T.2
  • 20
    • 0034100707 scopus 로고    scopus 로고
    • Spine update: Cervical spine internal fixation using screw and screw-plate constructs
    • McCullen GM, Garfin SR: Spine update: cervical spine internal fixation using screw and screw-plate constructs. Spine 25:643-652, 2000
    • (2000) Spine , vol.25 , pp. 643-652
    • McCullen, G.M.1    Garfin, S.R.2
  • 21
    • 0035420056 scopus 로고    scopus 로고
    • Biomechanical comparison of posterior cervical fixation
    • Mihara H, Cheng BC, David SM, et al: Biomechanical comparison of posterior cervical fixation. Spine 26:1662-1667, 2001
    • (2001) Spine , vol.26 , pp. 1662-1667
    • Mihara, H.1    Cheng, B.C.2    David, S.M.3
  • 22
    • 0026035433 scopus 로고
    • Biomechanics of cervical spine internal fixation
    • Montesano PX, Juach EC, Anderson PA, et al: Biomechanics of cervical spine internal fixation. Spine 16:S10-S16, 1991
    • (1991) Spine , vol.16
    • Montesano, P.X.1    Juach, E.C.2    Anderson, P.A.3
  • 23
    • 0026794946 scopus 로고
    • Anatomic and biomechanical study of posterior cervical spine plate arthrodesis: An evaluation of two different techniques of screw placement
    • Montesano PX, Jauch E, Jonsson H Jr: Anatomic and biomechanical study of posterior cervical spine plate arthrodesis: an evaluation of two different techniques of screw placement. J Spinal Disord 5:301-305, 1992
    • (1992) J Spinal Disord , vol.5 , pp. 301-305
    • Montesano, P.X.1    Jauch, E.2    Jonsson Jr., H.3
  • 24
    • 0034329881 scopus 로고    scopus 로고
    • Techniques and pitfalls of cervical lateral mass plate fixation
    • Muffoletto AJ, Hadjipavlou AG, Jensen RE, et al: Techniques and pitfalls of cervical lateral mass plate fixation. Am J Orthop 29:897-903, 2000
    • (2000) Am J Orthop , vol.29 , pp. 897-903
    • Muffoletto, A.J.1    Hadjipavlou, A.G.2    Jensen, R.E.3
  • 25
    • 0029023484 scopus 로고
    • European semi-anthropomorphic spine phantom for the calibration of bone densitometers: Assessment of precision, stability and accuracy
    • The European Quantitation of Osteoporosis Study Group
    • Pearson J, Dequeker J, Henley M, et al: European semi-anthropomorphic spine phantom for the calibration of bone densitometers: assessment of precision, stability and accuracy. The European Quantitation of Osteoporosis Study Group. Osteoporos Int 5:174-184, 1995
    • (1995) Osteoporos Int , vol.5 , pp. 174-184
    • Pearson, J.1    Dequeker, J.2    Henley, M.3
  • 26
    • 1542278554 scopus 로고
    • Etude bioméchanique de l' ancrage des vis pédiculaires dorsales et lombaires
    • Roy-Camille R, Garcon P, Begue TH, et al: Etude bioméchanique de l' ancrage des vis pédiculaires dorsales et lombaires. Rachis 3:109-114, 1991
    • (1991) Rachis , vol.3 , pp. 109-114
    • Roy-Camille, R.1    Garcon, P.2    Begue, T.H.3
  • 27
    • 0002454389 scopus 로고
    • Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws
    • Cervical Spine Research Society (eds). New York: Lippincott
    • Roy-Camille R, Saillant G, Mazel C: Internal fixation of the unstable cervical spine by a posterior osteosynthesis with plates and screws, in Cervical Spine Research Society (eds): The Cervical Spine. New York: Lippincott, 1989, pp 390-403
    • (1989) The Cervical Spine , pp. 390-403
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 28
    • 0032733596 scopus 로고    scopus 로고
    • Characteristics of unicortical and bicortical lateral mass screws in the cervical spine
    • Seybold EA, Baker JA, Criscitiello AA, et al: Characteristics of unicortical and bicortical lateral mass screws in the cervical spine. Spine 24:2397-2403, 1999
    • (1999) Spine , vol.24 , pp. 2397-2403
    • Seybold, E.A.1    Baker, J.A.2    Criscitiello, A.A.3
  • 29
    • 0025351033 scopus 로고
    • Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study
    • Skinner R, Maybee J, Transfeldt E, et al: Experimental pullout testing and comparison of variables in transpedicular screw fixation. A biomechanical study. Spine 15:195-201, 1990
    • (1990) Spine , vol.15 , pp. 195-201
    • Skinner, R.1    Maybee, J.2    Transfeldt, E.3
  • 30
    • 0031030970 scopus 로고    scopus 로고
    • A biomechanical study of a cervical spine stabilization device: Roy-Camille plates
    • Smith ME, Cibischino M, Langrana NA, et al: A biomechanical study of a cervical spine stabilization device: Roy-Camille plates. Spine 22:38-43, 1997
    • (1997) Spine , vol.22 , pp. 38-43
    • Smith, M.E.1    Cibischino, M.2    Langrana, N.A.3
  • 31
    • 0031059878 scopus 로고    scopus 로고
    • Rigid internal fixation with lateral mass plates in multilevel anterior and posterior reconstruction of the cervical spine
    • Swank ML, Sutterlin CE, Bossons CR, et al: Rigid internal fixation with lateral mass plates in multilevel anterior and posterior reconstruction of the cervical spine. Spine 22:274-282, 1997
    • (1997) Spine , vol.22 , pp. 274-282
    • Swank, M.L.1    Sutterlin, C.E.2    Bossons, C.R.3
  • 32
    • 0026775054 scopus 로고
    • Anterior and posterior plate stabilization of the cervical spine
    • Traynelis VC: Anterior and posterior plate stabilization of the cervical spine. Neurosurg Q 2:59-76, 1992
    • (1992) Neurosurg Q , vol.2 , pp. 59-76
    • Traynelis, V.C.1
  • 33
    • 0035057857 scopus 로고    scopus 로고
    • Internal fixation on the lower cervical spine-biomechanics and clinical practice of procedures and implants
    • Ulrich C, Arand M, Nothwang J: Internal fixation on the lower cervical spine-biomechanics and clinical practice of procedures and implants. Eur Spine J 10:88-100, 2001
    • (2001) Eur Spine J , vol.10 , pp. 88-100
    • Ulrich, C.1    Arand, M.2    Nothwang, J.3
  • 34
    • 0025970215 scopus 로고
    • Biomechanics of fixation systems to the cervical spine
    • Ulrich C, Woersdoerfer O, Kalff R, et al: Biomechanics of fixation systems to the cervical spine. Spine 16:S4-S9, 1991
    • (1991) Spine , vol.16
    • Ulrich, C.1    Woersdoerfer, O.2    Kalff, R.3
  • 35
    • 0032518499 scopus 로고    scopus 로고
    • Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients
    • Wellman BJ, Follett KA, Traynelis VC: Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients. Spine 23:193-200, 1998
    • (1998) Spine , vol.23 , pp. 193-200
    • Wellman, B.J.1    Follett, K.A.2    Traynelis, V.C.3
  • 36
    • 0031809357 scopus 로고    scopus 로고
    • Modified Magerl technique of lateral mass screw placement in the lower cervical spine: An anatomic study
    • Xu R, Ebraheim NA, Klausner T, et al: Modified Magerl technique of lateral mass screw placement in the lower cervical spine: an anatomic study. J Spinal Disord 11:237-240, 1998
    • (1998) J Spinal Disord , vol.11 , pp. 237-240
    • Xu, R.1    Ebraheim, N.A.2    Klausner, T.3
  • 37
    • 0028954599 scopus 로고
    • Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect
    • Xu R, Ebraheim NA, Yeasting R, et al: Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8:116-120, 1995.
    • (1995) J Spinal Disord , vol.8 , pp. 116-120
    • Xu, R.1    Ebraheim, N.A.2    Yeasting, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.