Volumn 192, Issue 2, 2009, Pages 341-351

False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: Long-term follow-up of 1,280 lesions and review of the literature

Author keywords

Breast needle biopsy; Breast neoplasms; Comparison biopsy; Diagnosis

Indexed keywords

ADULT; AGED; ARTICLE; BREAST BIOPSY; BREAST CANCER; BREAST DISEASE; CALCIFICATION; CANCER DIAGNOSIS; CANCER SURGERY; FALSE NEGATIVE RESULT; FEMALE; FOLLOW UP; HISTOLOGY; HUMAN; HUMAN TISSUE; INTRADUCTAL CARCINOMA; INVASIVE CARCINOMA; MAJOR CLINICAL STUDY; MAMMOGRAPHY; MEDICAL RECORD REVIEW; NEEDLE BIOPSY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STEREOTACTIC BIOPSY;

EID: 59349094273     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.08.1127     Document Type: Article
Times cited : (94)

References (41)
  • 2
    • 0037445974 scopus 로고    scopus 로고
    • False-negative core needle biopsies of the breast: An analysis of clinic, radiologic, and pathologic findings in 27 consecutive cases of missed breast cancer
    • Shah VI, Raju U, Chitale D, Deshpande V, Gregory N, Strand V. False-negative core needle biopsies of the breast: an analysis of clinic, radiologic, and pathologic findings in 27 consecutive cases of missed breast cancer. Cancer 2003; 97:1824-1831
    • (2003) Cancer , vol.97 , pp. 1824-1831
    • Shah, V.I.1    Raju, U.2    Chitale, D.3    Deshpande, V.4    Gregory, N.5    Strand, V.6
  • 3
    • 0034838585 scopus 로고    scopus 로고
    • Diagnostic accuracy of a stereotaxically guided vacuum-assisted large-core biopsy program in Canada
    • Lai JT, Burrowes P, MacGregor JH. Diagnostic accuracy of a stereotaxically guided vacuum-assisted large-core biopsy program in Canada. Can Assoc Radiol J 2001; 52:223-227
    • (2001) Can Assoc Radiol J , vol.52 , pp. 223-227
    • Lai, J.T.1    Burrowes, P.2    MacGregor, J.H.3
  • 4
    • 0036511204 scopus 로고    scopus 로고
    • Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognizable by ultrasonography
    • Apesteguia L, Mellado M, Saenz J, Cordero JL, Reparaz B, De Miguel C. Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognizable by ultrasonography. Eur Radiol 2002; 12:638-645
    • (2002) Eur Radiol , vol.12 , pp. 638-645
    • Apesteguia, L.1    Mellado, M.2    Saenz, J.3    Cordero, J.L.4    Reparaz, B.5    De Miguel, C.6
  • 5
    • 0036721251 scopus 로고    scopus 로고
    • To excise or to sample the mammographic target: What is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy?
    • Liberman L, Kaplan JB, Morris EA, Abramson AF, Menell JH, Dershaw DD. To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy? AJR 2002; 179:679-683
    • (2002) AJR , vol.179 , pp. 679-683
    • Liberman, L.1    Kaplan, J.B.2    Morris, E.A.3    Abramson, A.F.4    Menell, J.H.5    Dershaw, D.D.6
  • 6
    • 0036893114 scopus 로고    scopus 로고
    • Stereotactic 11-gauge vacuum-assisted breast biopsy: A validation study
    • Pfarl G, Helbich TH, Riedl CC, et al. Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR 2002; 179:1503-1507
    • (2002) AJR , vol.179 , pp. 1503-1507
    • Pfarl, G.1    Helbich, T.H.2    Riedl, C.C.3
  • 7
    • 0347985320 scopus 로고    scopus 로고
    • Stereotactic vacuum-assisted breast biopsy in 2874 patients
    • Kettritz U, Rotter K, Schreer I, et al. Stereotactic vacuum-assisted breast biopsy in 2874 patients. Cancer 2004; 100:245-251
    • (2004) Cancer , vol.100 , pp. 245-251
    • Kettritz, U.1    Rotter, K.2    Schreer, I.3
  • 8
    • 59349096094 scopus 로고    scopus 로고
    • Stereotactic vacuum-assisted breast biopsy in 2874 patients. (reply to letter)
    • Kettritz U. Stereotactic vacuum-assisted breast biopsy in 2874 patients. (reply to letter) Cancer 2004; 101:431
    • (2004) Cancer , vol.101 , pp. 431
    • Kettritz, U.1
  • 9
    • 0030774099 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Comparison of 14- and 11-gauge Mammotome probe performance and complication rates
    • Burbank F. Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates. Am Surg 1997; 63:988-995
    • (1997) Am Surg , vol.63 , pp. 988-995
    • Burbank, F.1
  • 10
    • 0031771461 scopus 로고    scopus 로고
    • Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques
    • Jackman RJ, Marzoni FA, Nowels KW. Percutaneous removal of benign mammographic lesions: comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques. AJR 1998; 171:1325-1330
    • (1998) AJR , vol.171 , pp. 1325-1330
    • Jackman, R.J.1    Marzoni, F.A.2    Nowels, K.W.3
  • 11
    • 0033761468 scopus 로고    scopus 로고
    • Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: Results of surgical excision
    • Darling ML, Smith DN, Lester SC, et al. Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: results of surgical excision. AJR 2000; 175:1341-1346
    • (2000) AJR , vol.175 , pp. 1341-1346
    • Darling, M.L.1    Smith, D.N.2    Lester, S.C.3
  • 12
    • 33645120598 scopus 로고    scopus 로고
    • Breast microcalcifications: Retrieval failure at prone stereotactic core and vacuum breast biopsy - frequency, causes, and outcome
    • Jackman RJ, Rodriguez-Soto J. Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy - frequency, causes, and outcome. Radiology 2006; 239:61-70
    • (2006) Radiology , vol.239 , pp. 61-70
    • Jackman, R.J.1    Rodriguez-Soto, J.2
  • 13
    • 0030787433 scopus 로고    scopus 로고
    • Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: Improved reliability with 14-gauge, directional, vacuum-assisted biopsy
    • Jackman RJ, Burbank F, Parker SH, et al. Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: improved reliability with 14-gauge, directional, vacuum-assisted biopsy. Radiology 1997; 204:485-488
    • (1997) Radiology , vol.204 , pp. 485-488
    • Jackman, R.J.1    Burbank, F.2    Parker, S.H.3
  • 14
    • 0035144642 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of nonpalpable lesions: Determinants of ductal carcinoma in situ underestimation rates
    • Jackman RJ, Burbank F, Parker SH, et al. Stereotactic breast biopsy of nonpalpable lesions: determinants of ductal carcinoma in situ underestimation rates. Radiology 2001; 218:497-502
    • (2001) Radiology , vol.218 , pp. 497-502
    • Jackman, R.J.1    Burbank, F.2    Parker, S.H.3
  • 15
    • 0036838432 scopus 로고    scopus 로고
    • Percutaneous core needle biopsy of radial scars of the breast: When is excision necessary?
    • Brenner RJ, Jackman RJ, Parker SH, et al. Percutaneous core needle biopsy of radial scars of the breast: when is excision necessary? AJR 2002; 179:1179-1184
    • (2002) AJR , vol.179 , pp. 1179-1184
    • Brenner, R.J.1    Jackman, R.J.2    Parker, S.H.3
  • 16
    • 1542264000 scopus 로고    scopus 로고
    • Stereotactic 11-gauge vacuum-assisted breast biopsy: Influence of number of specimens on diagnostic accuracy
    • Lomoschitz FM, Helbich TH, Rudas M, et al. Stereotactic 11-gauge vacuum-assisted breast biopsy: influence of number of specimens on diagnostic accuracy. Radiology 2004; 232:897-903
    • (2004) Radiology , vol.232 , pp. 897-903
    • Lomoschitz, F.M.1    Helbich, T.H.2    Rudas, M.3
  • 17
    • 0037369149 scopus 로고    scopus 로고
    • Stereotactic histologic biopsy with patients prone: Technical feasibility in 98% of mammographically detected lesions
    • Jackman RJ, Marzoni FA. Stereotactic histologic biopsy with patients prone: technical feasibility in 98% of mammographically detected lesions. AJR 2003; 180:785-794
    • (2003) AJR , vol.180 , pp. 785-794
    • Jackman, R.J.1    Marzoni, F.A.2
  • 18
    • 0036311741 scopus 로고    scopus 로고
    • Atypical ductal hyperplasia: Can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision?
    • Jackman RJ, Birdwell RL, Ikeda DM. Atypical ductal hyperplasia: can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision? Radiology 2002; 224:548-554
    • (2002) Radiology , vol.224 , pp. 548-554
    • Jackman, R.J.1    Birdwell, R.L.2    Ikeda, D.M.3
  • 19
    • 15744398275 scopus 로고    scopus 로고
    • Follow-up surgical excision is indicated when breast core needle biopsies show atypical lobular hyperplasia or lobular carcinoma in situ: A correlative study of 33 patients with review of the literature
    • Elsheikh TM, Silverman JF. Follow-up surgical excision is indicated when breast core needle biopsies show atypical lobular hyperplasia or lobular carcinoma in situ: a correlative study of 33 patients with review of the literature. Am J Surg Pathol 2005; 29:534-543
    • (2005) Am J Surg Pathol , vol.29 , pp. 534-543
    • Elsheikh, T.M.1    Silverman, J.F.2
  • 20
    • 39749105846 scopus 로고    scopus 로고
    • Lobular neoplasia at percutaneous breast biopsy: Variables associated with carcinoma at surgical excision
    • Brem RF, Lechner MC, Jackman RJ, et al. Lobular neoplasia at percutaneous breast biopsy: variables associated with carcinoma at surgical excision. AJR 2008; 190:637-641
    • (2008) AJR , vol.190 , pp. 637-641
    • Brem, R.F.1    Lechner, M.C.2    Jackman, R.J.3
  • 21
    • 33646690731 scopus 로고    scopus 로고
    • Management of radial scars found at percutaneous breast biopsy
    • Becker L, Trop I, David J, et al. Management of radial scars found at percutaneous breast biopsy. Can Assoc Radiol J 2006; 57:72-78
    • (2006) Can Assoc Radiol J , vol.57 , pp. 72-78
    • Becker, L.1    Trop, I.2    David, J.3
  • 22
    • 24144431542 scopus 로고    scopus 로고
    • Fibroepithelial lesions with cellular stroma on breast core needle biopsy: Are there predictors of outcome on surgical excision?
    • Jacobs TW, Chen YY, Guinee DG, et al. Fibroepithelial lesions with cellular stroma on breast core needle biopsy: are there predictors of outcome on surgical excision? Am J Clin Pathol 2005; 124:342-354
    • (2005) Am J Clin Pathol , vol.124 , pp. 342-354
    • Jacobs, T.W.1    Chen, Y.Y.2    Guinee, D.G.3
  • 25
    • 33745572727 scopus 로고    scopus 로고
    • Is surgical excision warranted after benign, concordant diagnosis of papilloma at percutaneous breast biopsy?
    • Liberman L, Tornos C, Huzjan R, Bartella L, Morris EA, Dershaw DD. Is surgical excision warranted after benign, concordant diagnosis of papilloma at percutaneous breast biopsy? AJR 2006; 186:1328-1334
    • (2006) AJR , vol.186 , pp. 1328-1334
    • Liberman, L.1    Tornos, C.2    Huzjan, R.3    Bartella, L.4    Morris, E.A.5    Dershaw, D.D.6
  • 26
    • 4344680282 scopus 로고    scopus 로고
    • Surgical excision is warranted following a core biopsy diagnosis of mucocoele-like lesion of the breast
    • Carder PJ, Murphy CE, Liston JC. Surgical excision is warranted following a core biopsy diagnosis of mucocoele-like lesion of the breast. Histopathology 2004; 45:148-154
    • (2004) Histopathology , vol.45 , pp. 148-154
    • Carder, P.J.1    Murphy, C.E.2    Liston, J.C.3
  • 27
    • 33745546605 scopus 로고    scopus 로고
    • Mucocelelike lesions of the breast: Mammographic findings with pathologic correlation
    • Leibman AJ, Staeger CN, Charney DA. Mucocelelike lesions of the breast: mammographic findings with pathologic correlation. AJR 2006; 186:1356-1360
    • (2006) AJR , vol.186 , pp. 1356-1360
    • Leibman, A.J.1    Staeger, C.N.2    Charney, D.A.3
  • 28
    • 0037325117 scopus 로고    scopus 로고
    • Histopathologic analysis of atypical lesions in image-guided core breast biopsies
    • Bonnett M, Wallis T, Rossmann M, et al. Histopathologic analysis of atypical lesions in image-guided core breast biopsies. Mod Pathol 2003; 16:154-160
    • (2003) Mod Pathol , vol.16 , pp. 154-160
    • Bonnett, M.1    Wallis, T.2    Rossmann, M.3
  • 29
    • 0003783933 scopus 로고    scopus 로고
    • American College of Radiology, 3rd ed. Reston, VA: American College of Radiology
    • American College of Radiology. Illustrated breast imaging reporting and data system (BI-RADS), 3rd ed. Reston, VA: American College of Radiology, 1998
    • (1998) Illustrated breast imaging reporting and data system (BI-RADS)
  • 30
    • 0034671616 scopus 로고    scopus 로고
    • Imaging-histologic discordance at percutaneous breast biopsy: An indicator of missed cancer
    • Liberman L, Drotman M, Morris EA, et al. Imaging-histologic discordance at percutaneous breast biopsy: an indicator of missed cancer. Cancer 2000; 89:2538-2546
    • (2000) Cancer , vol.89 , pp. 2538-2546
    • Liberman, L.1    Drotman, M.2    Morris, E.A.3
  • 31
    • 0032976596 scopus 로고    scopus 로고
    • Stereotactic, automated, large-core needle biopsy of non-palpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    • Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni FA, Finkelstein SI, Shepard MJ. Stereotactic, automated, large-core needle biopsy of non-palpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 1999; 210:799-805
    • (1999) Radiology , vol.210 , pp. 799-805
    • Jackman, R.J.1    Nowels, K.W.2    Rodriguez-Soto, J.3    Marzoni, F.A.4    Finkelstein, S.I.5    Shepard, M.J.6
  • 32
    • 0033008296 scopus 로고    scopus 로고
    • Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: Frequency of mammographic change and false-negative rate
    • Lee CH, Philpotts LE, Horvath LJ, Tocino I. Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: frequency of mammographic change and false-negative rate. Radiology 1999; 212:189-194
    • (1999) Radiology , vol.212 , pp. 189-194
    • Lee, C.H.1    Philpotts, L.E.2    Horvath, L.J.3    Tocino, I.4
  • 33
    • 0034011038 scopus 로고    scopus 로고
    • Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: A meta-analysis
    • Verkooijen HM, Peeters PH, Buskens E, et al. Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer 2000; 82:1017-1021
    • (2000) Br J Cancer , vol.82 , pp. 1017-1021
    • Verkooijen, H.M.1    Peeters, P.H.2    Buskens, E.3
  • 34
    • 0033810096 scopus 로고    scopus 로고
    • Stereotactic core-needle breast biopsy by surgeons: Minimum 2-year follow-up of benign lesions
    • Burns RP, Brown JP, Roe M, Sprouse LR, Yancey AE, Witherspoon LE. Stereotactic core-needle breast biopsy by surgeons: minimum 2-year follow-up of benign lesions. Ann Surg 2000; 232:542-548
    • (2000) Ann Surg , vol.232 , pp. 542-548
    • Burns, R.P.1    Brown, J.P.2    Roe, M.3    Sprouse, L.R.4    Yancey, A.E.5    Witherspoon, L.E.6
  • 35
    • 0031931765 scopus 로고    scopus 로고
    • Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy
    • Liberman L, Dershaw DD, Rosen PP, Morris EA, Abramson AF, Borgen PI. Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy. Radiology 1998; 206:711-715
    • (1998) Radiology , vol.206 , pp. 711-715
    • Liberman, L.1    Dershaw, D.D.2    Rosen, P.P.3    Morris, E.A.4    Abramson, A.F.5    Borgen, P.I.6
  • 36
    • 0032843390 scopus 로고    scopus 로고
    • Complete removal of non-palpable breast malignancies with a stereotactic percutaneous vacuum-assisted biopsy instrument
    • Gajdos C, Levy M, Herman Z, Herman G, Bleiweiss IJ, Tarter PI. Complete removal of non-palpable breast malignancies with a stereotactic percutaneous vacuum-assisted biopsy instrument. J Am Coll Surg 1999; 189:237-240
    • (1999) J Am Coll Surg , vol.189 , pp. 237-240
    • Gajdos, C.1    Levy, M.2    Herman, Z.3    Herman, G.4    Bleiweiss, I.J.5    Tarter, P.I.6
  • 38
    • 17344376758 scopus 로고    scopus 로고
    • Causes of inconsistency in diagnosing and classifying intraductal proliferations of the breast. European Commission Working Group on Breast Screening Pathology
    • Elston CW, Sloane JP, Amendoeira I, et al. Causes of inconsistency in diagnosing and classifying intraductal proliferations of the breast. European Commission Working Group on Breast Screening Pathology. Eur J Cancer 2000; 36:1769-1772
    • (2000) Eur J Cancer , vol.36 , pp. 1769-1772
    • Elston, C.W.1    Sloane, J.P.2    Amendoeira, I.3
  • 40
    • 0034856963 scopus 로고    scopus 로고
    • The significance of malignancies incidental to microcalcification in breast spot localization biopsy specimens
    • Rosenfeld I, Tartter PI, Gajdos C, Hermann G, Bleiweiss I. The significance of malignancies incidental to microcalcification in breast spot localization biopsy specimens. Am J Surg 2001; 182:1-5
    • (2001) Am J Surg , vol.182 , pp. 1-5
    • Rosenfeld, I.1    Tartter, P.I.2    Gajdos, C.3    Hermann, G.4    Bleiweiss, I.5
  • 41
    • 0030749032 scopus 로고    scopus 로고
    • Needle-localized breast biopsy: Why do we fail?
    • Jackman RJ, Marzoni FA. Needle-localized breast biopsy: why do we fail? Radiology 1997; 204:677-684
    • (1997) Radiology , vol.204 , pp. 677-684
    • Jackman, R.J.1    Marzoni, F.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.