-
1
-
-
44249116685
-
Digital dentistry: An overview of recent developments for CAD/CAM generated restorations
-
Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J. 2008 204 : 505 511.
-
(2008)
Br Dent J.
, vol.204
, pp. 505-511
-
-
Beuer, F.1
Schweiger, J.2
Edelhoff, D.3
-
2
-
-
0035453135
-
Alumina ceramic implant abutments used for single-tooth replacement: A prospective 1- to 3-year multicenter study
-
Andersson B, Taylor A, Lang BR, Scheller H, Scharer P, Sorensen JA et al. Alumina ceramic implant abutments used for single-tooth replacement: a prospective 1- to 3-year multicenter study. Int J Prosthodont. 2001 14 : 432 438.
-
(2001)
Int J Prosthodont.
, vol.14
, pp. 432-438
-
-
Andersson, B.1
Taylor, A.2
Lang, B.R.3
Scheller, H.4
Scharer, P.5
Sorensen, J.A.6
-
3
-
-
2342652157
-
Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years
-
Bindl A, Mormann WH. Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5 years. Eur J Oral Sci. 2004 112 : 197 204.
-
(2004)
Eur J Oral Sci.
, vol.112
, pp. 197-204
-
-
Bindl, A.1
Mormann, W.H.2
-
4
-
-
33644686403
-
Guidelines for success with zirconia ceramics: The changing standards
-
Devaud V. Guidelines for success with zirconia ceramics: the changing standards. Pract Proced Aesthet Dent. 2005 17 : 508 510.
-
(2005)
Pract Proced Aesthet Dent.
, vol.17
, pp. 508-510
-
-
Devaud, V.1
-
5
-
-
0036725232
-
Retention of selected core materials to zirconia posts
-
Edelhoff D, Sorensen JA. Retention of selected core materials to zirconia posts. Oper Dent. 2002 27 : 455 461.
-
(2002)
Oper Dent.
, vol.27
, pp. 455-461
-
-
Edelhoff, D.1
Sorensen, J.A.2
-
6
-
-
29644436765
-
All-ceramic fixed partial dentures. Part I: In vitro studies
-
Raigrodski AJ, Chiche GJ. All-ceramic fixed partial dentures. Part I: in vitro studies. J Esthet Restor Dent. 2002 14 : 188 191.
-
(2002)
J Esthet Restor Dent.
, vol.14
, pp. 188-191
-
-
Raigrodski, A.J.1
Chiche, G.J.2
-
8
-
-
34250653055
-
Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
-
Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007 20 : 383 388.
-
(2007)
Int J Prosthodont.
, vol.20
, pp. 383-388
-
-
Sailer, I.1
Feher, A.2
Filser, F.3
Gauckler, L.J.4
Luthy, H.5
Hammerle, C.H.6
-
10
-
-
14844364021
-
All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. a 2-year clinical study
-
Vult vonSteyernP, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. a 2-year clinical study. J Oral Rehabil. 2005 32 : 180 187.
-
(2005)
J Oral Rehabil.
, vol.32
, pp. 180-187
-
-
Vonsteyernp, V.1
Carlson, P.2
Nilner, K.3
-
11
-
-
0033868436
-
Advanced biomaterials used for a new telescopic retainer for removable dentures
-
Weigl P, Hahn L, Lauer HC. Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res. 2000 53 : 320 336.
-
(2000)
J Biomed Mater Res.
, vol.53
, pp. 320-336
-
-
Weigl, P.1
Hahn, L.2
Lauer, H.C.3
-
12
-
-
34247491685
-
Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks
-
Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci. 2007 115 : 161 166.
-
(2007)
Eur J Oral Sci.
, vol.115
, pp. 161-166
-
-
Kohorst, P.1
Herzog, T.J.2
Borchers, L.3
Stiesch-Scholz, M.4
-
13
-
-
25144478046
-
Strength and reliability of four unit all-ceramic posterior bridges
-
Luthy H, Filser F, Loeffel O, Schumacher M, Gauckler L, Hammerle CH. Strength and reliability of four unit all-ceramic posterior bridges. Dent Mater. 2005 21 : 930 937.
-
(2005)
Dent Mater.
, vol.21
, pp. 930-937
-
-
Luthy, H.1
Filser, F.2
Loeffel, O.3
Schumacher, M.4
Gauckler, L.5
Hammerle, C.H.6
-
15
-
-
33749677224
-
The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
-
Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S et al. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent. 2006 96 : 237 244.
-
(2006)
J Prosthet Dent.
, vol.96
, pp. 237-244
-
-
Raigrodski, A.J.1
Chiche, G.J.2
Potiket, N.3
Hochstedler, J.L.4
Mohamed, S.E.5
Billiot, S.6
-
16
-
-
29144487947
-
Load-to-fracture value of different all-ceramic crown systems
-
Snyder MD, Hogg KD. Load-to-fracture value of different all-ceramic crown systems. J Contemp Dent Pract. 2005 6 : 54 63.
-
(2005)
J Contemp Dent Pract.
, vol.6
, pp. 54-63
-
-
Snyder, M.D.1
Hogg, K.D.2
-
18
-
-
0035351260
-
Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: A laboratory study
-
Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001 14 : 231 238.
-
(2001)
Int J Prosthodont.
, vol.14
, pp. 231-238
-
-
Tinschert, J.1
Natt, G.2
Mautsch, W.3
Augthun, M.4
Spiekermann, H.5
-
19
-
-
33846988966
-
Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations
-
Tinschert J, Natt G, Mohrbotter N, Spiekermann H, Schulze KA. Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations. J Biomed Mater Res B Appl Biomater. 2007 80 : 317 321.
-
(2007)
J Biomed Mater Res B Appl Biomater.
, vol.80
, pp. 317-321
-
-
Tinschert, J.1
Natt, G.2
Mohrbotter, N.3
Spiekermann, H.4
Schulze, K.A.5
-
20
-
-
33646531223
-
The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic
-
Curtis AR, Wright AJ, Fleming GJ. The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic. J Dent. 2006 34 : 317 325.
-
(2006)
J Dent.
, vol.34
, pp. 317-325
-
-
Curtis, A.R.1
Wright, A.J.2
Fleming, G.J.3
-
21
-
-
32044466739
-
The influence of surface modification techniques on the performance of a Y-TZP dental ceramic
-
Curtis AR, Wright AJ, Fleming GJ. The influence of surface modification techniques on the performance of a Y-TZP dental ceramic. J Dent. 2006 34 : 195 206.
-
(2006)
J Dent.
, vol.34
, pp. 195-206
-
-
Curtis, A.R.1
Wright, A.J.2
Fleming, G.J.3
-
22
-
-
0033222358
-
The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic
-
Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater. 1999 15 : 426 433.
-
(1999)
Dent Mater.
, vol.15
, pp. 426-433
-
-
Kosmac, T.1
Oblak, C.2
Jevnikar, P.3
Funduk, N.4
Marion, L.5
-
23
-
-
17844402484
-
Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
-
Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci. 2005 113 : 174 179.
-
(2005)
Eur J Oral Sci.
, vol.113
, pp. 174-179
-
-
Reich, S.1
Wichmann, M.2
Nkenke, E.3
Proeschel, P.4
-
24
-
-
20044367673
-
Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
-
Bindl A, Mormann WH. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil. 2005 32 : 441 447.
-
(2005)
J Oral Rehabil.
, vol.32
, pp. 441-447
-
-
Bindl, A.1
Mormann, W.H.2
-
25
-
-
0024006282
-
A comparison of the marginal fit of three cast ceramic crown systems
-
Schaerer P, Sato T, Wohlwend A. A comparison of the marginal fit of three cast ceramic crown systems. J Prosthet Dent. 1988 59 : 534 542.
-
(1988)
J Prosthet Dent.
, vol.59
, pp. 534-542
-
-
Schaerer, P.1
Sato, T.2
Wohlwend, A.3
-
27
-
-
0025028550
-
Marginal fit of porcelain-fused-to-metal and two types of ceramic crown
-
Hung SH, Hung KS, Eick JD, Chappell RP. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent. 1990 63 : 26 31.
-
(1990)
J Prosthet Dent.
, vol.63
, pp. 26-31
-
-
Hung, S.H.1
Hung, K.S.2
Eick, J.D.3
Chappell, R.P.4
-
29
-
-
0021975697
-
Fit of three porcelain-fused-to-metal marginal designs in vivo: A scanning electron microscope study
-
Belser UC, MacEntee MI, Richter WA. Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent. 1985 53 : 24 29.
-
(1985)
J Prosthet Dent.
, vol.53
, pp. 24-29
-
-
Belser, U.C.1
MacEntee, M.I.2
Richter, W.A.3
-
30
-
-
0027620312
-
The fit of Procera titanium crowns. An in vitro and clinical study
-
Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand. 1993 51 : 129 134.
-
(1993)
Acta Odontol Scand.
, vol.51
, pp. 129-134
-
-
Karlsson, S.1
-
31
-
-
0015209415
-
The estimation of cement film thickness by an in vivo technique
-
McLean JW, von FraunhoferJA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971 131 : 107 111.
-
(1971)
Br Dent J.
, vol.131
, pp. 107-111
-
-
McLean, J.W.1
Von Fraunhofer, J.A.2
-
32
-
-
0031217183
-
A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns
-
Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. Int J Prosthodont. 1997 10 : 478 484.
-
(1997)
Int J Prosthodont.
, vol.10
, pp. 478-484
-
-
Sulaiman, F.1
Chai, J.2
Jameson, L.M.3
Wozniak, W.T.4
-
33
-
-
34250198314
-
Clinical study of the color stability of veneering ceramics for zirconia frameworks
-
Sailer I, Holderegger C, Jung RE, Suter A, Thievent B, Pietrobon N et al. Clinical study of the color stability of veneering ceramics for zirconia frameworks. Int J Prosthodont. 2007 20 : 263 269.
-
(2007)
Int J Prosthodont.
, vol.20
, pp. 263-269
-
-
Sailer, I.1
Holderegger, C.2
Jung, R.E.3
Suter, A.4
Thievent, B.5
Pietrobon, N.6
-
34
-
-
33746383047
-
Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques
-
Witkowski S, Komine F, Gerds T. Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. J Prosthet Dent. 2006 96 : 47 52.
-
(2006)
J Prosthet Dent.
, vol.96
, pp. 47-52
-
-
Witkowski, S.1
Komine, F.2
Gerds, T.3
-
35
-
-
0036886299
-
All-ceramic crowns: Bonding or cementing?
-
Pospiech P. All-ceramic crowns: bonding or cementing? Clin Oral Investig. 2002 6 : 189 197.
-
(2002)
Clin Oral Investig.
, vol.6
, pp. 189-197
-
-
Pospiech, P.1
-
36
-
-
2342478568
-
Crowns cemented on crown preparations lacking geometric resistance form. Part II: Effect of cement
-
Proussaefs P. Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement. J Prosthodont. 2004 13 : 36 41.
-
(2004)
J Prosthodont.
, vol.13
, pp. 36-41
-
-
Proussaefs, P.1
-
37
-
-
5444219837
-
Precision of a CAD/CAM technique for the production of zirconium dioxide copings
-
Coli P, Karlsson S. Precision of a CAD/CAM technique for the production of zirconium dioxide copings. Int J Prosthodont. 2004 17 : 577 580.
-
(2004)
Int J Prosthodont.
, vol.17
, pp. 577-580
-
-
Coli, P.1
Karlsson, S.2
-
39
-
-
22144498882
-
Clinical marginal and internal gaps of Procera AllCeram crowns
-
Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult vonSteyern P, Fukushima S. Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil. 2005 32 : 526 530.
-
(2005)
J Oral Rehabil.
, vol.32
, pp. 526-530
-
-
Kokubo, Y.1
Ohkubo, C.2
Tsumita, M.3
Miyashita, A.4
Vult Vonsteyern, P.5
Fukushima, S.6
-
40
-
-
10444286626
-
An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing
-
Luthardt RG, Bornemann G, Lemelson S, Walter MH, Huls A. An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont. 2004 17 : 680 685.
-
(2004)
Int J Prosthodont.
, vol.17
, pp. 680-685
-
-
Luthardt, R.G.1
Bornemann, G.2
Lemelson, S.3
Walter, M.H.4
Huls, A.5
-
41
-
-
36949012997
-
Fit of all-ceramic posterior fixed partial denture frameworks in vitro
-
Bindl A, Mormann WH. Fit of all-ceramic posterior fixed partial denture frameworks in vitro. Int J Periodontics Restorative Dent. 2007 27 : 567 575.
-
(2007)
Int J Periodontics Restorative Dent.
, vol.27
, pp. 567-575
-
-
Bindl, A.1
Mormann, W.H.2
|