메뉴 건너뛰기




Volumn 222, Issue 6, 2008, Pages 991-998

A statistical model and simulator for cardiovascular pressure signals

Author keywords

Arterial blood pressure; Intracranial pressure; Non invasive blood pressure simulators; Simulators

Indexed keywords

ARTERIAL BLOOD PRESSURE; CARDIAC FREQUENCIES; CARDIOVASCULAR PRESSURE SIGNALS; FREQUENCY DOMAINS; HEART RATE VARIABILITIES; INTRACRANIAL PRESSURE; NON-INVASIVE BLOOD PRESSURE SIMULATORS; PHYSIOLOGICAL SIGNALS; PRESSURE SIGNALS; PULSE PRESSURES; RESPIRATORY FREQUENCIES; STATISTICAL MODELS; SYNTHETIC SIGNALS; VALIDATION STUDIES; CARDIOVASCULAR PRESSURE SIGNAL; HEART RATE VARIABILITY; INTRA-CRANIAL PRESSURE; PULSE-PRESSURE VARIATIONS; RESPIRATORY FREQUENCY; TIME AND FREQUENCY DOMAINS;

EID: 58149142502     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM348     Document Type: Article
Times cited : (7)

References (35)
  • 1
    • 0033950920 scopus 로고    scopus 로고
    • Duchêne, J. and Hogrel, J. Y. A model of EMG generation. IEEE Trans. Biomed. Engng, 2000, 47(2), 192-201.
    • Duchêne, J. and Hogrel, J. Y. A model of EMG generation. IEEE Trans. Biomed. Engng, 2000, 47(2), 192-201.
  • 2
    • 0031132719 scopus 로고    scopus 로고
    • Simulation of nonstationary EEG
    • Kaipio, J. P. and Karjalainen, P. A. Simulation of nonstationary EEG. Biol. Cybernetics, 1997, 76(5), 349-356.
    • (1997) Biol. Cybernetics , vol.76 , Issue.5 , pp. 349-356
    • Kaipio, J.P.1    Karjalainen, P.A.2
  • 3
    • 0027739302 scopus 로고
    • Waveform estimation from noisy signals with variable signal delay using bispectrum averaging
    • Nakamura, M. Waveform estimation from noisy signals with variable signal delay using bispectrum averaging. IEEE Trans. Biomed. Engng, 1993, 40(2) ,118-127.
    • (1993) IEEE Trans. Biomed. Engng , vol.40 , Issue.2 , pp. 118-127
    • Nakamura, M.1
  • 4
    • 33746652211 scopus 로고    scopus 로고
    • Tracking tremor frequency in spike trains using the extended Kalman smoother
    • Kim, S. and McNames, J. Tracking tremor frequency in spike trains using the extended Kalman smoother. IEEE Trans. Biomed. Engng, 2006, 53(8), 1569-1577.
    • (2006) IEEE Trans. Biomed. Engng , vol.53 , Issue.8 , pp. 1569-1577
    • Kim, S.1    McNames, J.2
  • 5
    • 33746863672 scopus 로고    scopus 로고
    • An automatic algorithm for stationary segmentation of extracellular microelectrode recordings
    • Aboy, M. and Falkenberg, J. H. An automatic algorithm for stationary segmentation of extracellular microelectrode recordings. Med. Biol. Engng Computing, 2006, 44(6), 511-515.
    • (2006) Med. Biol. Engng Computing , vol.44 , Issue.6 , pp. 511-515
    • Aboy, M.1    Falkenberg, J.H.2
  • 6
    • 0032974147 scopus 로고    scopus 로고
    • Modeling of surface myoelectric signals -part II: Model-based signal interpretation
    • Merletti, R., Roy, S. H., Kupa, E., Roatta, S., and Granata, A. Modeling of surface myoelectric signals -part II: model-based signal interpretation. IEEE Trans. Biomed. Engng, 1999, 46(7), 821-829.
    • (1999) IEEE Trans. Biomed. Engng , vol.46 , Issue.7 , pp. 821-829
    • Merletti, R.1    Roy, S.H.2    Kupa, E.3    Roatta, S.4    Granata, A.5
  • 7
    • 1642372946 scopus 로고    scopus 로고
    • Surface EMG crosstalk evaluated from experimental recordings and simulated signals. Reflections on crosstalk interpretation, quantification and reduction
    • Farina, D., Merletti, R., Indino, B., and Graven- Nielsen, T. Surface EMG crosstalk evaluated from experimental recordings and simulated signals. Reflections on crosstalk interpretation, quantification and reduction. Meth. Inf. Medicine, 2004, 43(1), 30-35.
    • (2004) Meth. Inf. Medicine , vol.43 , Issue.1 , pp. 30-35
    • Farina, D.1    Merletti, R.2    Indino, B.3    Graven- Nielsen, T.4
  • 8
    • 0026444309 scopus 로고
    • Dectection of motor unit action potentials with surface electrodes: Influence of electrode size and spacing
    • Fuglevand, A. J., Winter, D. A., Patla, A. E., and Stashuk, D. Dectection of motor unit action potentials with surface electrodes: influence of electrode size and spacing. Biol. Cybernetics, 1992, 67(2), 143-153.
    • (1992) Biol. Cybernetics , vol.67 , Issue.2 , pp. 143-153
    • Fuglevand, A.J.1    Winter, D.A.2    Patla, A.E.3    Stashuk, D.4
  • 11
    • 0031213551 scopus 로고    scopus 로고
    • Estimation of event-related synchronization changes by a new TVAR method
    • Kaipio, J. P. and Karjalainen, P. A. Estimation of event-related synchronization changes by a new TVAR method. IEEE Trans. Biomed. Engng, 1997, 44(8), 649-656.
    • (1997) IEEE Trans. Biomed. Engng , vol.44 , Issue.8 , pp. 649-656
    • Kaipio, J.P.1    Karjalainen, P.A.2
  • 12
    • 0034283113 scopus 로고    scopus 로고
    • Nonlinear Markov process amplitude EEG model for nonlinear coupling interaction of spontaneous EEG
    • Bai, O., Nakamura, M., Ikeda, A., and Shibasaki, H. Nonlinear Markov process amplitude EEG model for nonlinear coupling interaction of spontaneous EEG. IEEE Trans. Biomed. Engng, 2000, 47(9), 1141-1146.
    • (2000) IEEE Trans. Biomed. Engng , vol.47 , Issue.9 , pp. 1141-1146
    • Bai, O.1    Nakamura, M.2    Ikeda, A.3    Shibasaki, H.4
  • 13
    • 0141646447 scopus 로고    scopus 로고
    • A mathematical approach to the temporal stationarity of background noise in MEG/ EEG measurements
    • Bijma, F., de Munck, J. C., Huizenga, H. M., and Hecthaar, R. M. A mathematical approach to the temporal stationarity of background noise in MEG/ EEG measurements. Neuroimage, 2003, 20(1), 233- 243.
    • (2003) Neuroimage , vol.20 , Issue.1 , pp. 233-243
    • Bijma, F.1    de Munck, J.C.2    Huizenga, H.M.3    Hecthaar, R.M.4
  • 14
    • 33750333534 scopus 로고    scopus 로고
    • Interpretation of the Lempel-Ziv complexity measure in the context of biomedical signal analysis
    • Aboy, M., Hornero, R., Abásolo, D., and Alvarez, D. Interpretation of the Lempel-Ziv complexity measure in the context of biomedical signal analysis. IEEE Trans. Biomed. Engng, 2006, 53(11), 2282-2288.
    • (2006) IEEE Trans. Biomed. Engng , vol.53 , Issue.11 , pp. 2282-2288
    • Aboy, M.1    Hornero, R.2    Abásolo, D.3    Alvarez, D.4
  • 15
    • 0035105006 scopus 로고    scopus 로고
    • Automatic computerized analysis of heart rate variability with digital filtering of ectopic beats
    • Storck, N., Ericson, M., Lindblad, L., and Jensen- Urstad, M. Automatic computerized analysis of heart rate variability with digital filtering of ectopic beats. Clin. Physiology, 2001, 21(1), 115-24.
    • (2001) Clin. Physiology , vol.21 , Issue.1 , pp. 115-124
    • Storck, N.1    Ericson, M.2    Lindblad, L.3    Jensen- Urstad, M.4
  • 16
    • 11244351526 scopus 로고    scopus 로고
    • Spike detection using the continuous wavelet transform
    • Nenadic, Z. and Burdick, J. W. Spike detection using the continuous wavelet transform. IEEE Trans. Biomed. Engng, 2005, 52(1), 74-87.
    • (2005) IEEE Trans. Biomed. Engng , vol.52 , Issue.1 , pp. 74-87
    • Nenadic, Z.1    Burdick, J.W.2
  • 17
    • 0031106763 scopus 로고    scopus 로고
    • A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV
    • Ruha, A., Sallinen, S., and Nissilä, S. A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV. IEEE Trans. Biomed. Engng, 1997, 44(3), 159-167.
    • (1997) IEEE Trans. Biomed. Engng , vol.44 , Issue.3 , pp. 159-167
    • Ruha, A.1    Sallinen, S.2    Nissilä, S.3
  • 19
    • 33645521404 scopus 로고    scopus 로고
    • A robust method for detection of linear and nonlinear interactions: Application to renal blood flow dynamics
    • Feng, L., Siu, K., Moore, L. C., Marsh, D. J., and Chon, K. H. A robust method for detection of linear and nonlinear interactions: application to renal blood flow dynamics. Ann. Biomed. Engng, 2006, 34(2), 339-353.
    • (2006) Ann. Biomed. Engng , vol.34 , Issue.2 , pp. 339-353
    • Feng, L.1    Siu, K.2    Moore, L.C.3    Marsh, D.J.4    Chon, K.H.5
  • 20
    • 0029935394 scopus 로고    scopus 로고
    • BreathSim, a mathematical model-based simulation of the anesthesia breathing circuit, may facilitate testing and evaluation of respiratory gas monitoring equipment
    • Goldman, J. M., Ward, D. R., and Daniel, L. BreathSim, a mathematical model-based simulation of the anesthesia breathing circuit, may facilitate testing and evaluation of respiratory gas monitoring equipment. Biomed. Sci. Instrumn, 1996, 32, 293-298.
    • (1996) Biomed. Sci. Instrumn , vol.32 , pp. 293-298
    • Goldman, J.M.1    Ward, D.R.2    Daniel, L.3
  • 21
    • 0025761673 scopus 로고
    • Finite limb dimensions and finite muscle length in a model for the generation of electromyographic signals. Electroencephalography Clin
    • Gootzen, T. H., Stegeman, D. F., and Van Oosterom, A. Finite limb dimensions and finite muscle length in a model for the generation of electromyographic signals. Electroencephalography Clin. Neurophysiology, 1991, 81(2), 152-162.
    • (1991) Neurophysiology , vol.81 , Issue.2 , pp. 152-162
    • Gootzen, T.H.1    Stegeman, D.F.2    Van Oosterom, A.3
  • 22
    • 3242666222 scopus 로고    scopus 로고
    • Beat-to-beat ECG ventricular late potentials variance detection by filter bank and wavelet transform as beat-sequence filter
    • Vai, M. I. and Zhou, L. G. Beat-to-beat ECG ventricular late potentials variance detection by filter bank and wavelet transform as beat-sequence filter. IEEE Trans. Biomed. Engng, 2004, 51(8), 1407-1413.
    • (2004) IEEE Trans. Biomed. Engng , vol.51 , Issue.8 , pp. 1407-1413
    • Vai, M.I.1    Zhou, L.G.2
  • 23
    • 0033918279 scopus 로고    scopus 로고
    • A simulation study of the consistency of oscillometric blood pressure measurements with and without artefacts
    • Amoore, J. N. A simulation study of the consistency of oscillometric blood pressure measurements with and without artefacts. Blood Pressure Monitoring, 2000, 5(2), 69-79.
    • (2000) Blood Pressure Monitoring , vol.5 , Issue.2 , pp. 69-79
    • Amoore, J.N.1
  • 24
    • 0033936833 scopus 로고    scopus 로고
    • Can simulators evaluate systematic differences between oscillometric non-invasive blood-pressure monitors?
    • Amoore, J. N. and Scot, D. H. Can simulators evaluate systematic differences between oscillometric non-invasive blood-pressure monitors? Blood Pressure Monitoring, 2000, 5(2), 81-89.
    • (2000) Blood Pressure Monitoring , vol.5 , Issue.2 , pp. 81-89
    • Amoore, J.N.1    Scot, D.H.2
  • 25
    • 18844415051 scopus 로고    scopus 로고
    • Oscillometric blood pressure devices and simulators: Measurements of repeatability and differences between models
    • Sims, A. J., Reay, C. A., Bousfield, D. R., Menes, J. A., and Murray, A. Oscillometric blood pressure devices and simulators: measurements of repeatability and differences between models. J. Med. Engng Technol., 2005, 29(3), 112-118.
    • (2005) J. Med. Engng Technol , vol.29 , Issue.3 , pp. 112-118
    • Sims, A.J.1    Reay, C.A.2    Bousfield, D.R.3    Menes, J.A.4    Murray, A.5
  • 26
    • 20044380065 scopus 로고    scopus 로고
    • Differences in oscillometric non-invasive blood pressure measurements recorded by different revisions of the Philips component monitoring system
    • Murray, I. C., Amoore, J. N., and Scott, D. H. T. Differences in oscillometric non-invasive blood pressure measurements recorded by different revisions of the Philips component monitoring system. Blood Pressure Monitoring, 2005, 10(4), 215-222.
    • (2005) Blood Pressure Monitoring , vol.10 , Issue.4 , pp. 215-222
    • Murray, I.C.1    Amoore, J.N.2    Scott, D.H.T.3
  • 27
    • 33744508715 scopus 로고    scopus 로고
    • Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices?
    • Amoore, J. N., Vacher, E., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., and Murray, A. Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? Blood Pressure Monitoring, 2006, 11(2), 63-67.
    • (2006) Blood Pressure Monitoring , vol.11 , Issue.2 , pp. 63-67
    • Amoore, J.N.1    Vacher, E.2    Murray, I.C.3    Mieke, S.4    King, S.T.5    Smith, F.E.6    Murray, A.7
  • 28
    • 0031088983 scopus 로고    scopus 로고
    • An evaluation of three oscillometric non-invasive blood pressure simulators
    • Amoore, J. N. and Geake, W. B. An evaluation of three oscillometric non-invasive blood pressure simulators. J. Clin. Engng, 1997, 22(2), 93-100.
    • (1997) J. Clin. Engng , vol.22 , Issue.2 , pp. 93-100
    • Amoore, J.N.1    Geake, W.B.2
  • 29
    • 0026945456 scopus 로고
    • Review of methods & simulators for evaluation of noninvasive blood pressure monitors
    • Ng, K. G. and Small, C. F. Review of methods & simulators for evaluation of noninvasive blood pressure monitors. J. Clin. Engng, 1992, 17(6), 469- 479.
    • (1992) J. Clin. Engng , vol.17 , Issue.6 , pp. 469-479
    • Ng, K.G.1    Small, C.F.2
  • 30
    • 0028397522 scopus 로고
    • Update on methods & simulators for evaluation of noninvasive bloodpressure monitors
    • Ng, K. G. and Small, C. F. Update on methods & simulators for evaluation of noninvasive bloodpressure monitors. J. Clin. Engng, 1994, 19(2), 125- 134.
    • (1994) J. Clin. Engng , vol.19 , Issue.2 , pp. 125-134
    • Ng, K.G.1    Small, C.F.2
  • 32
    • 23844483701 scopus 로고    scopus 로고
    • Adaptive modeling and spectral estimation of nonstationary biomedical signals based on Kalman filtering
    • Aboy, M., Márquez, O. W., McNames, J., Hornero, R., Trong, T., and Goldstein, B. Adaptive modeling and spectral estimation of nonstationary biomedical signals based on Kalman filtering. IEEE Trans. Biomed. Engng, 2005, 52(8), 1485-1489.
    • (2005) IEEE Trans. Biomed. Engng , vol.52 , Issue.8 , pp. 1485-1489
    • Aboy, M.1    Márquez, O.W.2    McNames, J.3    Hornero, R.4    Trong, T.5    Goldstein, B.6
  • 33
    • 0030045391 scopus 로고    scopus 로고
    • Laboratory testing of three intracranial pressure microtransducers: Technical report
    • Czosnyka, M., Czosnyka, Z., and Pickard, J. D. Laboratory testing of three intracranial pressure microtransducers: technical report. Neurosurgery, 1996, 38(1), 219-224.
    • (1996) Neurosurgery , vol.38 , Issue.1 , pp. 219-224
    • Czosnyka, M.1    Czosnyka, Z.2    Pickard, J.D.3
  • 34
    • 0030703187 scopus 로고    scopus 로고
    • Laboratory testing of the Spiegelberg brain pressure monitor: A technical report
    • Czosnyka, M., Czosnyka, Z., and Pickard, J. D. Laboratory testing of the Spiegelberg brain pressure monitor: a technical report. J. Neurology, Neurosurg. Psychiatry, 1997, 63(6), 732-735.
    • (1997) J. Neurology, Neurosurg. Psychiatry , vol.63 , Issue.6 , pp. 732-735
    • Czosnyka, M.1    Czosnyka, Z.2    Pickard, J.D.3
  • 35
    • 26444568107 scopus 로고    scopus 로고
    • Interpretation of approximate entropy: Analysis of intracranial pressure approximate entropy during acute intracranial hypertension
    • Hornero, R., Aboy, M., Abásolo, D., McNames, J., and Goldstein, B. Interpretation of approximate entropy: analysis of intracranial pressure approximate entropy during acute intracranial hypertension. IEEE Trans. Biomed. Engng, 2005, 52(10), 1671-1680.
    • (2005) IEEE Trans. Biomed. Engng , vol.52 , Issue.10 , pp. 1671-1680
    • Hornero, R.1    Aboy, M.2    Abásolo, D.3    McNames, J.4    Goldstein, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.