Can simulators evaluate systematic differences between oscillometric non-invasive blood-pressure monitors?

Author keywords

Blood pressure measurement; Evaluation; Non invasive blood pressure monitors; Simulators; Systematic errors

Indexed keywords

ACCURACY; ALGORITHM; ARTERIAL PRESSURE; ARTICLE; BLOOD PRESSURE MEASUREMENT; CALIBRATION; DIASTOLIC BLOOD PRESSURE; MEAN ARTERIAL PRESSURE; OSCILLOMETRY; PRIORITY JOURNAL; SIGNAL PROCESSING; SIMULATOR; SYSTOLIC BLOOD PRESSURE;

EID: 0033936833     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (28)

References (16)
  • 1
    • 0018376613 scopus 로고
    • Noninvasive automatic determination of mean arterial blood pressure
    • 1 Ramsey M III. Noninvasive automatic determination of mean arterial blood pressure. Med Biol Eng Comput 1979; 17:11-18.
    • (1979) Med Biol Eng Comput , vol.17 , pp. 11-18
    • Ramsey M. III1
  • 2
    • 0020307159 scopus 로고
    • Characterisation of the oscillometric method for measuring indirect blood pressure
    • 2 Geddes LA, Voelz M, Combs C, Reiner D, Babbs CF. Characterisation of the oscillometric method for measuring indirect blood pressure. Ann Biomed Eng 1982; 10:271-280.
    • (1982) Ann Biomed Eng , vol.10 , pp. 271-280
    • Geddes, L.A.1    Voelz, M.2    Combs, C.3    Reiner, D.4    Babbs, C.F.5
  • 3
    • 0028532654 scopus 로고
    • Survey of automated non-invasive blood pressure monitors
    • 3 Ng K-G, Small CF. Survey of automated non-invasive blood pressure monitors. J Clin Eng 1994; 19:452-475.
    • (1994) J Clin Eng , vol.19 , pp. 452-475
    • Ng, K.-G.1    Small, C.F.2
  • 4
    • 0001849046 scopus 로고
    • The British Hypertension Society protocol for the evaluation of blood pressure measuring devices
    • 4 O'Brien E, Petrie J, Littler R, De Sweit M, Padfield PL, Altman D, et al. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens 1993; 11 (suppl 2):S43-S63.
    • (1993) J Hypertens , vol.11 , Issue.SUPPL. 2
    • O'Brien, E.1    Petrie, J.2    Littler, R.3    De Sweit, M.4    Padfield, P.L.5    Altman, D.6
  • 5
    • 0027479012 scopus 로고
    • National standard for measurement of resting and ambulatory blood pressure with automated sphygmomanometers
    • 5 White WB, Berson AS, Robbins C, Jamieson MJ, Prisant LM, Roccella E, et al. National standard for measurement of resting and ambulatory blood pressure with automated sphygmomanometers. Hypertension 1993; 21:504-509.
    • (1993) Hypertension , vol.21 , pp. 504-509
    • White, W.B.1    Berson, A.S.2    Robbins, C.3    Jamieson, M.J.4    Prisant, L.M.5    Roccella, E.6
  • 6
    • 0026945456 scopus 로고
    • Review of methods and simulators for evaluation of non-invasive blood pressure monitors
    • 6 Ng K-G, Small CF. Review of methods and simulators for evaluation of non-invasive blood pressure monitors. J Clin Eng 1992; 17:469-479.
    • (1992) J Clin Eng , vol.17 , pp. 469-479
    • Ng, K.-G.1    Small, C.F.2
  • 7
    • 0030946816 scopus 로고    scopus 로고
    • Evaluation of the Critikon 8100 and SpaceLabs 90207 non-invasive blood pressure monitors using a test simulator
    • 7 Amoore JN, Geake WB. Evaluation of the Critikon 8100 and SpaceLabs 90207 non-invasive blood pressure monitors using a test simulator. J Hum Hypertens 1997; 11:163-169.
    • (1997) J Hum Hypertens , vol.11 , pp. 163-169
    • Amoore, J.N.1    Geake, W.B.2
  • 8
    • 0031434311 scopus 로고    scopus 로고
    • Substitution of simulators for human subjects
    • 8 Mieke S. Substitution of simulators for human subjects. Blood Press Monit 1997; 2:251-256.
    • (1997) Blood Press Monit , vol.2 , pp. 251-256
    • Mieke, S.1
  • 9
    • 0031464019 scopus 로고    scopus 로고
    • Considerations for simulation-based evaluation of noninvasive blood pressure monitors
    • 9 Ng K-G. Considerations for simulation-based evaluation of noninvasive blood pressure monitors. Blood Press Monit 1997; 2:256-268.
    • (1997) Blood Press Monit , vol.2 , pp. 256-268
    • Ng, K.-G.1
  • 10
    • 0032408393 scopus 로고    scopus 로고
    • A comparative evaluation of the DINAMAP 8100 and DINAMAP Compact TS using an NIBP simulator
    • 10 Amoore JN. A comparative evaluation of the DINAMAP 8100 and DINAMAP Compact TS using an NIBP simulator. Blood Press Monit 1998; 3:309-314.
    • (1998) Blood Press Monit , vol.3 , pp. 309-314
    • Amoore, J.N.1
  • 11
    • 0031088983 scopus 로고    scopus 로고
    • An evaluation of three oscillometric non-invasive blood pressure simulators
    • 11 Amoore JN, Geake WB. An evaluation of three oscillometric non-invasive blood pressure simulators. J Clin Eng 1997; 22:93-100.
    • (1997) J Clin Eng , vol.22 , pp. 93-100
    • Amoore, J.N.1    Geake, W.B.2
  • 12
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 12 Bland JM Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0025186940 scopus 로고
    • Assessment of four ambulatory blood pressure monitors and measurements by clinicians versus intraarterial blood pressure at rest and during exercise
    • 13 White WB, Lund-Johansen P, Omvik P. Assessment of four ambulatory blood pressure monitors and measurements by clinicians versus intraarterial blood pressure at rest and during exercise. Am J Cardiol 1990; 65:60-66.
    • (1990) Am J Cardiol , vol.65 , pp. 60-66
    • White, W.B.1    Lund-Johansen, P.2    Omvik, P.3
  • 14
    • 0023686899 scopus 로고
    • Validation of portable noninvasive blood pressure monitoring devices: Comparisons with intra-arterial and sphygmomanometer measurements
    • 14 Graettinger WF, Lipson JL, Cheung DG, Weber MA. Validation of portable noninvasive blood pressure monitoring devices: comparisons with intra-arterial and sphygmomanometer measurements. Am Heart J 1988; 116:1155-1160.
    • (1988) Am Heart J , vol.116 , pp. 1155-1160
    • Graettinger, W.F.1    Lipson, J.L.2    Cheung, D.G.3    Weber, M.A.4
  • 15
    • 0030110895 scopus 로고    scopus 로고
    • An arm phantom: A digital simulation system for testing sphygmomanometers
    • 15 Groß H, Mieke S, Ulbrich M. An arm phantom: a digital simulation system for testing sphygmomanometers. J Med Eng Tech 1996; 20:75 -83.
    • (1996) J Med Eng Tech , vol.20 , pp. 75-83
    • Groß, H.1    Mieke, S.2    Ulbrich, M.3
  • 16
    • 0031105405 scopus 로고    scopus 로고
    • Oscillometric non invasive blood pressure measurements: The influence of the make of instrument on the reading?
    • 16 Amoore JN, Geake WB, Scott DHT. Oscillometric non invasive blood pressure measurements: the influence of the make of instrument on the reading? Med Biol Eng Comput 1997; 35:131-134.
    • (1997) Med Biol Eng Comput , vol.35 , pp. 131-134
    • Amoore, J.N.1    Geake, W.B.2    Scott, D.H.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.