Volumn 55, Issue 5, 2008, Pages 2465-2474

A novel time-based readout scheme for a combined PET-CT detector using APDs

Author keywords

Avalanche photodiodes (APD); lutetium oxyorthosilicate (LSO); time based readout; Time over threshold discrimination

Indexed keywords

AVALANCHE PHOTODIODES; AVALANCHES (SNOWSLIDES); DIAGNOSTIC RADIOGRAPHY; ELECTRIC INSTRUMENT TRANSFORMERS; FADING (RADIO); LUTETIUM; MEDICAL APPLICATIONS; MEDICAL IMAGING; OPTOELECTRONIC DEVICES; PHOTODETECTORS; PHOTODIODES; PHOTONS; POSITRON ANNIHILATION SPECTROSCOPY; SIGNAL PROCESSING; SIGNAL TO NOISE RATIO; SNOW; TOMOGRAPHY;

EID: 57849102152     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2008.2004036     Document Type: Article
Times cited : (26)

References (21)
  • 1
    • 1642633805 scopus 로고    scopus 로고
    • PET/CT today and tomorrow
    • D. W. Townsend et al., "PET/CT today and tomorrow," J. Nucl. Med., vol. 45, no. 1, pp. 4-14, 2004.
    • (2004) J. Nucl. Med , vol.45 , Issue.1 , pp. 4-14
    • Townsend, D.W.1
  • 2
    • 23844550282 scopus 로고    scopus 로고
    • Architecture of a dual-modality, high-resolution, fully digital positron emission tomography/computed tomography (PET/CT) scanner for small animal imaging
    • Jun
    • R. Fontaine et al., "Architecture of a dual-modality, high-resolution, fully digital positron emission tomography/computed tomography (PET/CT) scanner for small animal imaging," IEEE Trans. Nucl. Sci., vol. 52, no. 3, pp. 691-696, Jun. 2005.
    • (2005) IEEE Trans. Nucl. Sci , vol.52 , Issue.3 , pp. 691-696
    • Fontaine, R.1
  • 3
    • 35348969898 scopus 로고    scopus 로고
    • The road to the common PET/CT detector
    • Oct
    • A. Nassalski et al., "The road to the common PET/CT detector," IEEE Trans. Nucl. Sci., vol. 54, no. 5, pp. 1464-1473, Oct. 2007.
    • (2007) IEEE Trans. Nucl. Sci , vol.54 , Issue.5 , pp. 1464-1473
    • Nassalski, A.1
  • 4
    • 57849140185 scopus 로고    scopus 로고
    • BioCare (Molecular Imaging for Biologically Optimized Cancer Therapy), European Commission 6th Framework, Proposal No. 505 785 [Online], Available: http://www.biocare-eu.com/home.aspx?r=4&s=1&ss=
    • BioCare (Molecular Imaging for Biologically Optimized Cancer Therapy), European Commission 6th Framework, Proposal No. 505 785 [Online], Available: http://www.biocare-eu.com/home.aspx?r=4&s=1&ss=
  • 5
    • 0027649130 scopus 로고
    • 2(SiO4)O:Ce
    • Aug
    • 2(SiO4)O:Ce," IEEE Trans. Nucl. Sci., vol. 40, no. 4, pp. 380-383. Aug. 1993.
    • (1993) IEEE Trans. Nucl. Sci , vol.40 , Issue.4 , pp. 380-383
    • Suzuki, H.1
  • 6
    • 3042626143 scopus 로고    scopus 로고
    • Scintillation: Mechanisms and new crystals
    • M. J. Weber, "Scintillation: Mechanisms and new crystals," Nucl. Instrum. Methods Phys. Res. A, vol. A527, pp. 9-14, 2004.
    • (2004) Nucl. Instrum. Methods Phys. Res. A , vol.A527 , pp. 9-14
    • Weber, M.J.1
  • 7
    • 57849138346 scopus 로고    scopus 로고
    • Online, Available
    • Hamamatsu [Online]. Available: http://jp.hamamatsu.com/products/sensor- ssd/pd078/pd079/pd085/S8550/index-en.ht l
    • Hamamatsu
  • 8
    • 0032685865 scopus 로고    scopus 로고
    • Characterization of avalanche photodiodes for calorimetry applications
    • J. Ch. Vanel, "Characterization of avalanche photodiodes for calorimetry applications," Nucl. Instrum. Methods Phys. Res. A, vol. A428, pp. 413-431, 1999.
    • (1999) Nucl. Instrum. Methods Phys. Res. A , vol.A428 , pp. 413-431
    • Vanel, J.C.1
  • 9
    • 0038521578 scopus 로고    scopus 로고
    • Hamamatsu S8550 APD arrays for high-resolution scintillator matrices readout
    • M. Kapusta et al., "Hamamatsu S8550 APD arrays for high-resolution scintillator matrices readout," Nucl. Instrum. Methods Phys. Res. A, vol. A504, pp. 139-142, 2003.
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.A504 , pp. 139-142
    • Kapusta, M.1
  • 10
    • 33144470922 scopus 로고    scopus 로고
    • Fast CMOS binary front end for silicon strip detectors at LHC experiments
    • Dec
    • J. Kaplon et al., "Fast CMOS binary front end for silicon strip detectors at LHC experiments," IEEE Trans. Nucl. Sci., vol. 52, no. 6, pp. 2713-2720, Dec. 2005.
    • (2005) IEEE Trans. Nucl. Sci , vol.52 , Issue.6 , pp. 2713-2720
    • Kaplon, J.1
  • 11
    • 77949903911 scopus 로고    scopus 로고
    • Online, Available
    • ATLAS Collaboration [Online]. Available: http://atlas.web.cern.ch/Atlas/ index.html
    • ATLAS Collaboration
  • 12
    • 8344272162 scopus 로고    scopus 로고
    • NINO: An ultrafast low-power front-end amplifier discriminator for the time-of-flight detector in the ALICE experiment
    • Oct
    • F. Anghinolfi et al., "NINO: An ultrafast low-power front-end amplifier discriminator for the time-of-flight detector in the ALICE experiment," IEEE Trans. Nucl. Sci., vol. 51, no. 5, pp. 1974-1978, Oct. 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , Issue.5 , pp. 1974-1978
    • Anghinolfi, F.1
  • 13
    • 84887462248 scopus 로고    scopus 로고
    • Online, Available
    • ALICE Collaboration [Online]. Available: http://aliceinfo.cern.ch
    • ALICE Collaboration
  • 14
    • 57849138346 scopus 로고    scopus 로고
    • Online, Available
    • Hamamatsu [Online]. Available: http://jp.hamamatsu.com/products/sensor- etd/pd002/pd394/H6533/index-en.html
    • Hamamatsu
  • 15
    • 0033337104 scopus 로고    scopus 로고
    • Prospect for time-of-flight PET using LSO scintillators
    • Jun
    • W. W. Moses, "Prospect for time-of-flight PET using LSO scintillators," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 474-478, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci , vol.46 , Issue.3 , pp. 474-478
    • Moses, W.W.1
  • 16
    • 4644367934 scopus 로고    scopus 로고
    • Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET
    • Sep
    • B. J. Pichler et al., "Lutetium oxyorthosilicate block detector readout by avalanche photodiode arrays for high resolution animal PET," Phys. Med. Biol., vol. 49, pp. 4305-4319, Sep. 2004.
    • (2004) Phys. Med. Biol , vol.49 , pp. 4305-4319
    • Pichler, B.J.1
  • 17
    • 24044500009 scopus 로고    scopus 로고
    • A four-layer attenuation compensated PET detector based on APD arrays without discrete crystal elements
    • Aug
    • S. McCallum, "A four-layer attenuation compensated PET detector based on APD arrays without discrete crystal elements," Phys. Med. Biol, vol. 50, pp. 4187-4207, Aug. 2005.
    • (2005) Phys. Med. Biol , vol.50 , pp. 4187-4207
    • McCallum, S.1
  • 18
    • 3342876838 scopus 로고    scopus 로고
    • Properties of LYSO and recent LSO scintillators for phoswich PET detectors
    • Jun
    • C. Pepin et al., "Properties of LYSO and recent LSO scintillators for phoswich PET detectors," IEEE Trans. Nucl. Sci., vol. 51, no. 3, pp. 789-795, Jun. 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.51 , Issue.3 , pp. 789-795
    • Pepin, C.1
  • 19
    • 0037845128 scopus 로고    scopus 로고
    • Analysis of timing performance for an APD-LSO scintillation detector
    • M. E. Casey et al., "Analysis of timing performance for an APD-LSO scintillation detector," Nucl. Inustrum. Methods Phys. Res. A, vol. A504, pp. 143-148, 2003.
    • (2003) Nucl. Inustrum. Methods Phys. Res. A , vol.A504 , pp. 143-148
    • Casey, M.E.1
  • 21
    • 84930556197 scopus 로고
    • Improved timing with NaI(Tl)
    • Jun
    • F. J. Lynch, "Improved timing with NaI(Tl)," IEEE Trans. Nucl. Sci., vol. 13, no. 3, pp. 140-147, Jun. 1966.
    • (1966) IEEE Trans. Nucl. Sci , vol.13 , Issue.3 , pp. 140-147
    • Lynch, F.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.