메뉴 건너뛰기




Volumn 50, Issue 17, 2005, Pages 4187-4207

A four-layer attenuation compensated PET detector based on APD arrays without discrete crystal elements

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CRYSTALS; ELECTROMAGNETIC WAVE ATTENUATION; LINEARIZATION; PHOTODIODES; PHOTOMULTIPLIERS; PHOTONS; SCINTILLATION COUNTERS;

EID: 24044500009     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/50/17/019     Document Type: Article
Times cited : (26)

References (11)
  • 1
    • 84939045331 scopus 로고
    • A multicrystal 2-dimensional BGO detector system for positron emission tomography
    • Casey M E and Nutt R 1986 A multicrystal 2-dimensional BGO detector system for positron emission tomography IEEE Trans. Nucl. Sci. 33 460-3
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , pp. 460-463
    • Casey, M.E.1    Nutt, R.2
  • 2
    • 34648840245 scopus 로고    scopus 로고
    • MicroPET: A high resolution PET scanner for imaging small animals
    • Cherry S R et al 1997 MicroPET: a high resolution PET scanner for imaging small animals IEEE Trans. Nucl. Sci. 44 1161-6
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 1161-1166
    • Cherry, S.R.1
  • 4
    • 0037151412 scopus 로고    scopus 로고
    • cMiCE: A high-resolution animal PET using continuous LSO with a statistics based positioning scheme
    • Joung J, Miyaoka R S and Lewellen T K 2002 cMiCE: a high-resolution animal PET using continuous LSO with a statistics based positioning scheme Nucl. Instum. Methods A 489 584-98
    • (2002) Nucl. Instum. Methods A , vol.489 , pp. 584-598
    • Joung, J.1    Miyaoka, R.S.2    Lewellen, T.K.3
  • 5
    • 0036815754 scopus 로고    scopus 로고
    • Design of a high resolution and high sensitivity scintillation crystal array for PET with nearly complete light collection
    • Levin C S 2002 Design of a high resolution and high sensitivity scintillation crystal array for PET with nearly complete light collection IEEE Trans. Nucl. Sci. 49 2236-43
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 2236-2243
    • Levin, C.S.1
  • 6
    • 0027998907 scopus 로고
    • High resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using avalanche photodiode detectors
    • Marriott C J, Cadorette J E, Lecomte R, Scasnar V, Rousseau J and van Lier J E 1994 High resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using avalanche photodiode detectors J. Nucl. Med. 35 1390-6
    • (1994) J. Nucl. Med. , vol.35 , pp. 1390-1396
    • Marriott, C.J.1    Cadorette, J.E.2    Lecomte, R.3    Scasnar, V.4    Rousseau, J.5    Van Lier, J.E.6
  • 8
    • 0035428676 scopus 로고    scopus 로고
    • A 4 x 8 APD array, consisting of two monolithic silicon waters coupled to a 32-channel LSO matrix for high-resolution PET
    • Pichler B J, Bernecker F, Boning G, Rafecas M, Pimpl M, Lorenz E and Ziegler S 2001 A 4 x 8 APD array, consisting of two monolithic silicon waters coupled to a 32-channel LSO matrix for high-resolution PET IEEE Trans. Nucl. Sci. 48 1391-6
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 1391-1396
    • Pichler, B.J.1    Bernecker, F.2    Boning, G.3    Rafecas, M.4    Pimpl, M.5    Lorenz, E.6    Ziegler, S.7
  • 11
    • 0035428527 scopus 로고    scopus 로고
    • Design and simulation of continuous scintillator with pixellated photodetector
    • Takacs G J, Rosenfeld A B and Lerch M L F 2001 Design and simulation of continuous scintillator with pixellated photodetector IEEE Trans. Nucl. Sci. 48 1412-7
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 1412-1417
    • Takacs, G.J.1    Rosenfeld, A.B.2    Lerch, M.L.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.