메뉴 건너뛰기




Volumn 52, Issue 3 I, 2005, Pages 691-696

Architecture of a dual-modality, high-resolution, fully digital positron emission tomography/computed tomography (PET/CT) scanner for small animal imaging

Author keywords

Computed tomography; Digital signal processing; Field programmable gate array (FPGA); Positron emission tomography

Indexed keywords

DATA PROCESSING; DIGITAL SIGNAL PROCESSING; DRUG PRODUCTS; FIELD PROGRAMMABLE GATE ARRAYS; IMAGE CODING; MEDICAL IMAGING; RADIATION EFFECTS; SCANNING; X RAY ANALYSIS;

EID: 23844550282     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.850484     Document Type: Article
Times cited : (46)

References (24)
  • 1
    • 0032939061 scopus 로고    scopus 로고
    • Interpretation of phenotype in genetically engineered mice
    • T. Doetschman,"Interpretation of phenotype in genetically engineered mice,"Laboratory Animal Sci., vol. 49, no. 2, pp. 137-143, 1999.
    • (1999) Laboratory Animal Sci. , vol.49 , Issue.2 , pp. 137-143
    • Doetschman, T.1
  • 2
    • 0142027639 scopus 로고    scopus 로고
    • Applications of positron emission tomography in the development of molecular targeted cancer therapeutics
    • B. Solomon, G. A. McArthur, C. Cullinane, J. R. Zalcberg, and R. J. Hicks,"Applications of positron emission tomography in the development of molecular targeted cancer therapeutics,"Biodrugs, vol. 17, no. 5, pp. 339-354, 2003.
    • (2003) Biodrugs , vol.17 , Issue.5 , pp. 339-354
    • Solomon, B.1    McArthur, G.A.2    Cullinane, C.3    Zalcberg, J.R.4    Hicks, R.J.5
  • 3
    • 9144223146 scopus 로고    scopus 로고
    • Assessment of cancer associated biomarkers by positron emission tomography: Advances and challenges
    • T. L. Collier et al.,"Assessment of cancer associated biomarkers by positron emission tomography: Advances and challenges,"Disease Markers, vol. 18, no. 5-6, pp. 211-247, 2002.
    • (2002) Disease Markers , vol.18 , Issue.5-6 , pp. 211-247
    • Collier, T.L.1
  • 4
    • 34248396529 scopus 로고    scopus 로고
    • Features of the NIH ATLAS small animal PET scanner and its use with a coaxial small animal volume CT scanner
    • Bethesda, MD
    • J. Siedel, J. J. Vaquero, J. Pascau, M. Desco, C. A. Johnson, and M. Green,"Features of the NIH ATLAS small animal PET scanner and its use with a coaxial small animal volume CT scanner,"in Proc. IEEE Int. Symp. Biomedical Imaging, Bethesda, MD, 2002, pp. 545-548.
    • (2002) Proc. IEEE Int. Symp. Biomedical Imaging , pp. 545-548
    • Siedel, J.1    Vaquero, J.J.2    Pascau, J.3    Desco, M.4    Johnson, C.A.5    Green, M.6
  • 5
    • 0037153878 scopus 로고    scopus 로고
    • Simultaneous molecular and anatomical imaging of the mouse in vivo
    • A. L. Goertzen, A. K. Meadors, R. W. Silverman, and S. R. Cherry,"Simultaneous molecular and anatomical imaging of the mouse in vivo,"Phys. Med. Biol., vol. 47, pp. 4315-4328, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 4315-4328
    • Goertzen, A.L.1    Meadors, A.K.2    Silverman, R.W.3    Cherry, S.R.4
  • 8
    • 0003958379 scopus 로고
    • Catalogue of spectral data for diagnostic X-rays
    • Hospital Physicists' Association, London
    • R. Birch, M. Marshall, and G. M. Ardran,"Catalogue of Spectral Data for Diagnostic X-Rays,"Hospital Physicists' Association, London, Scientific Report Series-30, 1979.
    • (1979) Scientific Report Series-30
    • Birch, R.1    Marshall, M.2    Ardran, G.M.3
  • 9
    • 0036815735 scopus 로고    scopus 로고
    • Design of a fast shaping amplifier for PET/CT APD detectors with depth-of-interaction
    • Oct.
    • J.-F. Pratte, J. Mouine, C. M. Pepin, D. Rouleau, and R. Lecomte,"Design of a fast shaping amplifier for PET/CT APD detectors with depth-of-interaction,"IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2448-2454, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5 , pp. 2448-2454
    • Pratte, J.-F.1    Mouine, J.2    Pepin, C.M.3    Rouleau, D.4    Lecomte, R.5
  • 11
    • 2942724677 scopus 로고    scopus 로고
    • Technology challenges in small animal PET imaging
    • to be published
    • R. Lecomte,"Technology challenges in small animal PET imaging,"Nucl. Instrum. Meth. Phys. Res. A, to be published.
    • Nucl. Instrum. Meth. Phys. Res. A
    • Lecomte, R.1
  • 12
    • 0038720472 scopus 로고    scopus 로고
    • Pulse shape discrimination of LSO and Lu YAP scintillators for depth of interaction detection in PET
    • Jun.
    • M. Streun et al.,"Pulse shape discrimination of LSO and Lu YAP scintillators for depth of interaction detection in PET,"IEEE Trans. Nucl. Sci., vol. 50, no. 3, pp. 344-347, Jun. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.3 , pp. 344-347
    • Streun, M.1
  • 13
    • 0034593847 scopus 로고    scopus 로고
    • A modular VME or IBM PC based data acquisition system for multi-modality PET/CT scanners of different sizes and detector types
    • Lyon, France
    • D. B. Crosetto,"A modular VME or IBM PC based data acquisition system for multi-modality PET/CT scanners of different sizes and detector types,"in Proc. 2000 IEEE Nuclear Science Symp. Conf. Rec., vol. 2, Lyon, France, pp. 12/78-12/97.
    • Proc. 2000 IEEE Nuclear Science Symp. Conf. Rec. , vol.2
    • Crosetto, D.B.1
  • 14
    • 0033321161 scopus 로고    scopus 로고
    • Advantages using pulse shape discrimination to assign the depth of interaction information (DOI) from a multilayer phoswich detector
    • Aug.
    • M. Schmand, L. Eriksson, M. E. Casey, K. Wienhard, G. Flugge, and R. Nutt,"Advantages using pulse shape discrimination to assign the depth of interaction information (DOI) from a multilayer phoswich detector,"IEEE Trans. Nucl. Sci., vol. 46, no. 4, pp. 985-990, Aug. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.4 , pp. 985-990
    • Schmand, M.1    Eriksson, L.2    Casey, M.E.3    Wienhard, K.4    Flugge, G.5    Nutt, R.6
  • 15
    • 0033311839 scopus 로고    scopus 로고
    • Depth identification accuracy of a three layer phoswich PET detector module
    • Jun.
    • J. Seidel, J. J. Vaquero, S. Siegel, W. R. Gandler, and M. V. Green,"Depth identification accuracy of a three layer phoswich PET detector module,"IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 485-490, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 485-490
    • Seidel, J.1    Vaquero, J.J.2    Siegel, S.3    Gandler, W.R.4    Green, M.V.5
  • 16
    • 0033308956 scopus 로고    scopus 로고
    • Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes
    • Jun.
    • A. Saoudi et al.,"Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes,"IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 462-467, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 462-467
    • Saoudi, A.1
  • 17
    • 2942751670 scopus 로고
    • A new dual crystal depth sensitive detector for high resolution PET cameras
    • R. Lecomte,"A new dual crystal depth sensitive detector for high resolution PET cameras,"J. Nucl. Med., vol. 27, p. 974, 1986.
    • (1986) J. Nucl. Med. , vol.27 , pp. 974
    • Lecomte, R.1
  • 18
    • 0028493624 scopus 로고
    • Design and engineering aspects of a high resolution positron tomograph for small animal imaging
    • Aug.
    • R. Lecomte, J. Cadorette, P. Richard, S. Rodrigue, and D. Rouleau,"Design and engineering aspects of a high resolution positron tomograph for small animal imaging,"IEEE Trans. Nucl. Sci., vol. 41, no. 4, pp. 1446-1452, Aug. 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , Issue.4 , pp. 1446-1452
    • Lecomte, R.1    Cadorette, J.2    Richard, P.3    Rodrigue, S.4    Rouleau, D.5
  • 19
    • 0035355031 scopus 로고    scopus 로고
    • Performance analysis of phoswich/APD detectors and low noise CMOS preamplifiers for high resolution PET systems
    • Jun.
    • R. Lecomte, C. M. Pepin, M. D. Lepage, J.-F. Pratte, and D. M. Binkley,"Performance analysis of phoswich/APD detectors and low noise CMOS preamplifiers for high resolution PET systems,"IEEE Trans. Nucl. Sci., vol. 48, no. 3, pp. 650-655, Jun. 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , Issue.3 , pp. 650-655
    • Lecomte, R.1    Pepin, C.M.2    Lepage, M.D.3    Pratte, J.-F.4    Binkley, D.M.5
  • 20
  • 21
    • 11844294558 scopus 로고    scopus 로고
    • Time determination by digital signal processing with BGO-APD detectors in positron emission tomography
    • Montreal, QC, Canada
    • J.-D. Leroux et al.,"Time determination by digital signal processing with BGO-APD detectors in positron emission tomography,"in Proc. IEEE/NPSS 13th Real Time Conf., Montreal, QC, Canada, 2003, pp. 1723-1727.
    • (2003) Proc. IEEE/NPSS 13th Real Time Conf. , pp. 1723-1727
    • Leroux, J.-D.1
  • 23
    • 8844238704 scopus 로고    scopus 로고
    • Xilinx Inc., DS077-1, 2.0 ed.
    • [23]"Spartan-IIE 1.8V FPGA Family,"Xilinx Inc., DS077-1, 2.0 ed., 2002.
    • (2002) Spartan-IIE 1.8V FPGA Family
  • 24
    • 1542347439 scopus 로고    scopus 로고
    • Real-time pole-and-zero-space analysis for discrimination of multilayer detectors used for depth-of-interaction measurement in positron emission tomography
    • Montreal, QC, Canada
    • J.-B. Michaud, R. Fontaine, and R. Lecomte,"Real-time pole-and-zero-space analysis for discrimination of multilayer detectors used for depth-of-interaction measurement in positron emission tomography,"in Proc. IEEE/NPSS 13th Real Time Conf., Montreal, QC, Canada, 2003.
    • (2003) Proc. IEEE/NPSS 13th Real Time Conf.
    • Michaud, J.-B.1    Fontaine, R.2    Lecomte, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.