메뉴 건너뛰기




Volumn 14, Issue 34, 2008, Pages 10727-10734

Hemoglobin on phosphonic acid terminated self-assembled monolayers at a gold electrode: Immobilization, direct electrochemistry, and electrocatalysis

Author keywords

Electrocatalysis; Electrochemistry; Monolayers proteins; Self assembly

Indexed keywords

ABSORPTION SPECTROSCOPY; ACIDS; BIOSENSORS; CATALYSIS; CYCLIC VOLTAMMETRY; ELECTROCATALYSIS; ELECTROCHEMICAL ELECTRODES; ELECTROCHEMISTRY; ELECTROLYSIS; ELECTRON ENERGY LEVELS; FLOW INTERACTIONS; HEMOGLOBIN; HYDROGEN; HYDROGEN BONDS; HYDROGEN PEROXIDE; INFRARED SPECTROSCOPY; MISSILE BASES; ORGANIC ACIDS;

EID: 56749131181     PISSN: 09476539     EISSN: 15213765     Source Type: Journal    
DOI: 10.1002/chem.200801503     Document Type: Article
Times cited : (50)

References (88)
  • 6
    • 35748935084 scopus 로고    scopus 로고
    • R. Y. Zhang, X. M. Wang, K. K. Shiu, L. Colloid Interface Sci. 2007, 316, 517-522;
    • a) R. Y. Zhang, X. M. Wang, K. K. Shiu, L. Colloid Interface Sci. 2007, 316, 517-522;
  • 58
    • 0004122938 scopus 로고
    • Ed, G. Zubay, Addison-Wesley, New York, Chap. 2
    • J. Beckwith, R. M. Bell, S. Beychok, Biochemistry, Vol. 1 (Ed.: G. Zubay), Addison-Wesley, New York 1984, Chap. 2.
    • (1984) Biochemistry , vol.1
    • Beckwith, J.1    Bell, R.M.2    Beychok, S.3
  • 59
    • 0034269896 scopus 로고    scopus 로고
    • a2 values of 11-mercaptoundecanylphosphonic acid monolayers on gold surface were estimated to be 4.5 and 8.4 by chemical force microscopy (a) D. A. Smith. J. Phys. Chem. B 2000, 104, 8862-8870;
    • a2 values of 11-mercaptoundecanylphosphonic acid monolayers on gold surface were estimated to be 4.5 and 8.4 by chemical force microscopy (a) D. A. Smith. J. Phys. Chem. B 2000, 104, 8862-8870;
  • 60
    • 0034193534 scopus 로고    scopus 로고
    • a2 values of the self-assembled MPPA molecules are certainly smaller than 4.5 and 8.4, respectively, which means that the MPPAJ. Au electrode should be negatively charged in 10mM NaAcJ.HAc buffer solution (pH 5.4).
    • a2 values of the self-assembled MPPA molecules are certainly smaller than 4.5 and 8.4, respectively, which means that the MPPAJ. Au electrode should be negatively charged in 10mM NaAcJ.HAc buffer solution (pH 5.4).
  • 75
    • 56749140632 scopus 로고    scopus 로고
    • In polentiostatic polarization treatment experiments (data not shown), we found that an applied potential of -0.3 V does not result in obvious desorplion of Hb immobilized on an MPPA/Au electrode.
    • In polentiostatic polarization treatment experiments (data not shown), we found that an applied potential of -0.3 V does not result in obvious desorplion of Hb immobilized on an MPPA/Au electrode.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.