메뉴 건너뛰기




Volumn 136, Issue 5, 2008, Pages 1142-1148

Bovine pericardial versus porcine stented replacement aortic valves: Early results of a randomized comparison of the Perimount and the Mosaic valves

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA VALVE DISEASE; AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTICLE; CARPENTIER EDWARDS BIOPROSTHESIS; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EXERCISE TEST; FEMALE; HEART HEMODYNAMICS; HEART LEFT VENTRICLE MASS; HEART VALVE BIOPROSTHESIS; HUMAN; MAJOR CLINICAL STUDY; MALE; PHYSICAL CAPACITY; POSTOPERATIVE PERIOD; PRESSURE; PRIORITY JOURNAL; PSYCHOLOGIC ASSESSMENT; QUALITY OF LIFE; QUESTIONNAIRE; RANDOMIZED CONTROLLED TRIAL; SURGICAL MORTALITY; TREATMENT OUTCOME;

EID: 56249089987     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2007.12.086     Document Type: Article
Times cited : (41)

References (30)
  • 2
    • 0025179228 scopus 로고
    • Validation and application of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
    • Dumesnil J.G., Honos G.N., Lemieux M., and Beauchemin J. Validation and application of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 16 (1990) 637-643
    • (1990) J Am Coll Cardiol , vol.16 , pp. 637-643
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 3
    • 0021875340 scopus 로고
    • Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves
    • Williams G.A., and Labovitz A.J. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. Am J Cardiol 56 (1985) 325-332
    • (1985) Am J Cardiol , vol.56 , pp. 325-332
    • Williams, G.A.1    Labovitz, A.J.2
  • 4
    • 0030462265 scopus 로고    scopus 로고
    • Discrepancies between labeled and actual dimensions of prosthetic valves and sizers
    • Cochran R., and Kunzelman K. Discrepancies between labeled and actual dimensions of prosthetic valves and sizers. Card Surg 11 (1996) 318-324
    • (1996) Card Surg , vol.11 , pp. 318-324
    • Cochran, R.1    Kunzelman, K.2
  • 5
    • 18244372666 scopus 로고    scopus 로고
    • Exercise hemodynamics of bovine versus porcine bioprostheses: a prospective randomized comparison of the Mosaic and Perimount aortic valves
    • Eichinger W.B., Botzenhardt F., Keithahn A., Guenzinger R., Bleiziffer S., Wagner I., et al. Exercise hemodynamics of bovine versus porcine bioprostheses: a prospective randomized comparison of the Mosaic and Perimount aortic valves. J Thorac Cardiovasc Surg 129 (2005) 1056-1063
    • (2005) J Thorac Cardiovasc Surg , vol.129 , pp. 1056-1063
    • Eichinger, W.B.1    Botzenhardt, F.2    Keithahn, A.3    Guenzinger, R.4    Bleiziffer, S.5    Wagner, I.6
  • 7
    • 0018231715 scopus 로고
    • Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements
    • the Committee on M-mode Standardization of the American Society of Echocardiography
    • Sahn D.J., De Maria A., Kisslo J., Weyman A.E., and the Committee on M-mode Standardization of the American Society of Echocardiography. Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements. Circulation 58 (1978) 1072-1081
    • (1978) Circulation , vol.58 , pp. 1072-1081
    • Sahn, D.J.1    De Maria, A.2    Kisslo, J.3    Weyman, A.E.4
  • 9
    • 0025974281 scopus 로고
    • Conceptualizing and measuring generic health outcomes
    • Ware J.E. Conceptualizing and measuring generic health outcomes. Cancer 67 (1991) 774-779
    • (1991) Cancer , vol.67 , pp. 774-779
    • Ware, J.E.1
  • 10
    • 0003714450 scopus 로고
    • Stewart A.L., and Ware J.E. (Eds), Duke University Press, Durham
    • In: Stewart A.L., and Ware J.E. (Eds). Measuring functioning and well-being (1992), Duke University Press, Durham
    • (1992) Measuring functioning and well-being
  • 11
    • 0020527558 scopus 로고
    • The hospital anxiety and depression scale
    • Zigmond A.S., and Snaith R.P. The hospital anxiety and depression scale. Acta Psychiat Scand 67 (1983) 61-70
    • (1983) Acta Psychiat Scand , vol.67 , pp. 61-70
    • Zigmond, A.S.1    Snaith, R.P.2
  • 12
  • 13
    • 0027959891 scopus 로고
    • Early clinical and hemodynamic evaluation of aortic Intact porcine bioprosthesis
    • Mullaby C.J., Schaff H.V., Orszlak T.A., and Miller F.A. Early clinical and hemodynamic evaluation of aortic Intact porcine bioprosthesis. J Heart Valve Dis 3 (1994) 641-647
    • (1994) J Heart Valve Dis , vol.3 , pp. 641-647
    • Mullaby, C.J.1    Schaff, H.V.2    Orszlak, T.A.3    Miller, F.A.4
  • 15
    • 0035014882 scopus 로고    scopus 로고
    • Hemodynamic comparison of second- and third-generation stented bioprosthetses in aortic valve replacement
    • Jamieson W.R., Janusz M.T., MacNab J., and Henderson C. Hemodynamic comparison of second- and third-generation stented bioprosthetses in aortic valve replacement. Ann Thorac Surg 71 (2001) S282-S284
    • (2001) Ann Thorac Surg , vol.71
    • Jamieson, W.R.1    Janusz, M.T.2    MacNab, J.3    Henderson, C.4
  • 16
    • 0035089127 scopus 로고    scopus 로고
    • Echocardiographic assessment and preliminary clinical results after aortic valve replacement with the Medtronic Mosaic bioprosthesis
    • Corbineau H., Lelong B., Langanay T., Verhoye J.P., and Leguerrier A. Echocardiographic assessment and preliminary clinical results after aortic valve replacement with the Medtronic Mosaic bioprosthesis. J Heart Valve Dis 10 (2001) 171-176
    • (2001) J Heart Valve Dis , vol.10 , pp. 171-176
    • Corbineau, H.1    Lelong, B.2    Langanay, T.3    Verhoye, J.P.4    Leguerrier, A.5
  • 18
    • 7044269343 scopus 로고    scopus 로고
    • The Mosaic valve clinical performance at seven years: results from a multicenter prospective clinical trial
    • Fradet G.J., Bleese N., Busse E., Jamieson E., Raudkivi P., Goldstein J., et al. The Mosaic valve clinical performance at seven years: results from a multicenter prospective clinical trial. J Heart Valve Dis 13 (2004) 239-246
    • (2004) J Heart Valve Dis , vol.13 , pp. 239-246
    • Fradet, G.J.1    Bleese, N.2    Busse, E.3    Jamieson, E.4    Raudkivi, P.5    Goldstein, J.6
  • 22
    • 4644299165 scopus 로고    scopus 로고
    • Prospectively randomized evaluation of stented xenograft hemodynamic function in the aortic position
    • Walther T., Lehmann S., Fal V., Metz S., Doll N., Rastan A., et al. Prospectively randomized evaluation of stented xenograft hemodynamic function in the aortic position. Circulation 110 11 Suppl 1 (2004) II74-II78
    • (2004) Circulation , vol.110 , Issue.11 SUPPL. 1
    • Walther, T.1    Lehmann, S.2    Fal, V.3    Metz, S.4    Doll, N.5    Rastan, A.6
  • 23
    • 0036658324 scopus 로고    scopus 로고
    • Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis
    • Dellgren G., David T.E., Raanani E., Armstrong S., Ivanov J., and Rakowski H. Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis. J Thorac Cardiovasc Surg 124 (2002) 146-154
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 146-154
    • Dellgren, G.1    David, T.E.2    Raanani, E.3    Armstrong, S.4    Ivanov, J.5    Rakowski, H.6
  • 24
    • 24644520436 scopus 로고    scopus 로고
    • A randomized comparison of the MCRI On-X and Carbomedics "Top Hat" bileaflet mechanical replacement aortic valves: early postoperative hemodynamic function and clinical events
    • Chambers J., Roxburgh J., Blauth C., O'Riordan J., Hodson F., and Rimington H. A randomized comparison of the MCRI On-X and Carbomedics "Top Hat" bileaflet mechanical replacement aortic valves: early postoperative hemodynamic function and clinical events. J Thorac Cardiovasc Surg 130 (2005) 759-764
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 759-764
    • Chambers, J.1    Roxburgh, J.2    Blauth, C.3    O'Riordan, J.4    Hodson, F.5    Rimington, H.6
  • 26
    • 0026911341 scopus 로고
    • Outcomes management in heart valve replacement surgery: early experience
    • Phillips R.C., and Lansky D.J. Outcomes management in heart valve replacement surgery: early experience. J Heart Valve Dis 1 (1992) 42-50
    • (1992) J Heart Valve Dis , vol.1 , pp. 42-50
    • Phillips, R.C.1    Lansky, D.J.2
  • 27
    • 0042859863 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    • Blais C., Dumesnil J.G., Baillot R., Simard S., Doyle D., and Pibarot P. Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108 (2003) 983-988
    • (2003) Circulation , vol.108 , pp. 983-988
    • Blais, C.1    Dumesnil, J.G.2    Baillot, R.3    Simard, S.4    Doyle, D.5    Pibarot, P.6
  • 28
    • 33644858444 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
    • Tasca G., Mhagna Z., Perotti S., Centurini P.B., Sabatini T., Amaducci A., et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 113 (2006) 570-576
    • (2006) Circulation , vol.113 , pp. 570-576
    • Tasca, G.1    Mhagna, Z.2    Perotti, S.3    Centurini, P.B.4    Sabatini, T.5    Amaducci, A.6
  • 29
    • 33644870470 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on long-term survival in patients with small St. Jude Medical mechanical prostheses in the aortic position
    • Mohty D., Malouf J.F., Girard S.E., Schaff H.V., Grill D.E., Enriquez-Sarano M.E., et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St. Jude Medical mechanical prostheses in the aortic position. Circulation 113 (2006) 420-426
    • (2006) Circulation , vol.113 , pp. 420-426
    • Mohty, D.1    Malouf, J.F.2    Girard, S.E.3    Schaff, H.V.4    Grill, D.E.5    Enriquez-Sarano, M.E.6
  • 30
    • 34249795452 scopus 로고    scopus 로고
    • One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study
    • Dalmau M.J., Maria Gonzalez-Santos J., Lopez-Rodriguez J., Bueno M., Arribas A., and Nieto F. One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study. Interact Cardiovasc Thorac Surg 6 (2007) 345-349
    • (2007) Interact Cardiovasc Thorac Surg , vol.6 , pp. 345-349
    • Dalmau, M.J.1    Maria Gonzalez-Santos, J.2    Lopez-Rodriguez, J.3    Bueno, M.4    Arribas, A.5    Nieto, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.