Volumn 25, Issue 12, 2008, Pages 995-1001

Image-based monitoring of one-lung ventilation

Author keywords

Imaging, vibration response imaging; Intubation intratracheal; Pulmonary ventilation, regional airflow distribution; Respiration artificial, one lung

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL VENTILATION; BIOMEDICAL TECHNOLOGY ASSESSMENT; CLINICAL ARTICLE; ENDOTRACHEAL INTUBATION; FEMALE; HUMAN; IMAGING SYSTEM; MALE; PATIENT MONITORING; RESPIRATORY AIRFLOW; SOUND TRANSMISSION; VIBRATION; VISUAL DISPLAY UNIT;

EID: 55749085096     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1017/S0265021508004481     Document Type: Article
Times cited : (7)

References (12)
  • 1
    • 1342322661 scopus 로고    scopus 로고
    • Double-lumen tube position should be confirmed by fiberoptic bronchoscopy
    • Cohen E. Double-lumen tube position should be confirmed by fiberoptic bronchoscopy. Curr Opin Anaesthesiol 2004; 17: 1-6.
    • (2004) Curr Opin Anaesthesiol , vol.17 , pp. 1-6
    • Cohen, E.1
  • 2
    • 33644965437 scopus 로고    scopus 로고
    • Devices for lung isolation used by anesthesiologists with limited thoracic experience
    • Campos JH, Hallam EA, Van Natta T, Kernstine KH. Devices for lung isolation used by anesthesiologists with limited thoracic experience. Anesthesiology 2006; 104: 261-266.
    • (2006) Anesthesiology , vol.104 , pp. 261-266
    • Campos, J.H.1    Hallam, E.A.2    Van Natta, T.3    Kernstine, K.H.4
  • 3
    • 23944466588 scopus 로고    scopus 로고
    • Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes
    • O'Connor CJ, Mansy H, Balk RA et al. Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes. Anesth Analg 2005; 101: 735-739.
    • (2005) Anesth Analg , vol.101 , pp. 735-739
    • O'Connor, C.J.1    Mansy, H.2    Balk, R.A.3
  • 4
    • 33845670411 scopus 로고    scopus 로고
    • Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation
    • Tejman-Yarden S, Lederman D, Eilig I et al. Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation. Anesth Analg 2006; 103: 1489-1493.
    • (2006) Anesth Analg , vol.103 , pp. 1489-1493
    • Tejman-Yarden, S.1    Lederman, D.2    Eilig, I.3
  • 5
    • 33947655985 scopus 로고    scopus 로고
    • Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode
    • Dellinger RP, Jean S, Cinel I et al. Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode. Crit Care 2007; 11(1): R26.
    • (2007) Crit Care , vol.11 , Issue.1
    • Dellinger, R.P.1    Jean, S.2    Cinel, I.3
  • 6
    • 38049089433 scopus 로고    scopus 로고
    • Dynamic Visualization of Lung Sounds with a Vibration Response Device: A Case Series
    • Dellinger RP, Parrillo JE, Kushnir A et al. Dynamic Visualization of Lung Sounds with a Vibration Response Device: A Case Series. Respiration 2008; 75: 60-72.
    • (2008) Respiration , vol.75 , pp. 60-72
    • Dellinger, R.P.1    Parrillo, J.E.2    Kushnir, A.3
  • 7
    • 41349121176 scopus 로고    scopus 로고
    • Vibration response imaging findings following inadvertent esophageal intubation
    • Cinel I, Jean S, Tay C et al. Vibration response imaging findings following inadvertent esophageal intubation. Can J Anaesth 2008; 55(3): 172-176.
    • (2008) Can J Anaesth , vol.55 , Issue.3 , pp. 172-176
    • Cinel, I.1    Jean, S.2    Tay, C.3
  • 9
    • 0031913886 scopus 로고    scopus 로고
    • Role of fiberoptic bronchoscopy in conjunction with the use of doublelumen tubes for thoracic anesthesia: A prospective study
    • Klein U, Karzai W, Bloos F et al. Role of fiberoptic bronchoscopy in conjunction with the use of doublelumen tubes for thoracic anesthesia: a prospective study. Anesthesiology 1998; 88: 346-350.
    • (1998) Anesthesiology , vol.88 , pp. 346-350
    • Klein, U.1    Karzai, W.2    Bloos, F.3
  • 10
    • 0742272007 scopus 로고    scopus 로고
    • Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation
    • Inoue S, Nishimine N, Kitaguchi K et al. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation. Br J Anaesth 2004; 92: 195-201.
    • (2004) Br J Anaesth , vol.92 , pp. 195-201
    • Inoue, S.1    Nishimine, N.2    Kitaguchi, K.3
  • 11
    • 34547561685 scopus 로고    scopus 로고
    • Acoustic monitoring of lung sounds for the detection of one-lung intubation
    • Tejman-Yarden S, Zlotnik A, Weizman L et al. Acoustic monitoring of lung sounds for the detection of one-lung intubation. Anesth Analg 2007; 105: 397-404.
    • (2007) Anesth Analg , vol.105 , pp. 397-404
    • Tejman-Yarden, S.1    Zlotnik, A.2    Weizman, L.3
  • 12
    • 0026663046 scopus 로고
    • Reliability of auscultation in positioning of double-lumen endobronchial tubes
    • Alliaume B, Coddens J, Deloof T. Reliability of auscultation in positioning of double-lumen endobronchial tubes. Can J Anaesth 1992; 39: 687-690.
    • (1992) Can J Anaesth , vol.39 , pp. 687-690
    • Alliaume, B.1    Coddens, J.2    Deloof, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.