메뉴 건너뛰기




Volumn 103, Issue 6, 2006, Pages 1489-1493

Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTICS; ARTICLE; CALCULATION; CLINICAL ARTICLE; DIAGNOSTIC ACCURACY; ENDOTRACHEAL INTUBATION; FILTER; FOREARM; HUMAN; LUNG VENTILATION; MICROPHONE; MONITORING; ONE LUNG INTUBATION; PIEZOELECTRICITY; POSITION; PRIORITY JOURNAL; RECORDING; RESPIRATORY FUNCTION DISORDER; RESPIRATORY TRACT DISEASE; SENSOR; SIGNAL NOISE RATIO; SIGNAL PROCESSING; THORAX SURGERY; VENTILATED PATIENT;

EID: 33845670411     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ane.0000240909.48774.49     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 0027380416 scopus 로고
    • The Australian Incident Monitoring Study. Problems related to the endotracheal tube: An analysis of 2000 incident reports
    • Szekely SM, Webb RK, Williamson JA, Russell WJ. The Australian Incident Monitoring Study. Problems related to the endotracheal tube: an analysis of 2000 incident reports. Anesth Intensive Care 1993;21:611-6.
    • (1993) Anesth Intensive Care , vol.21 , pp. 611-616
    • Szekely, S.M.1    Webb, R.K.2    Williamson, J.A.3    Russell, W.J.4
  • 2
    • 0026547164 scopus 로고
    • Complications of endotracheal intubation and mechanical ventilation in infants and children
    • Rivera R, Tibballs J. Complications of endotracheal intubation and mechanical ventilation in infants and children. Crit Care Med 1992;20:193-9.
    • (1992) Crit Care Med , vol.20 , pp. 193-199
    • Rivera, R.1    Tibballs, J.2
  • 3
    • 0035124139 scopus 로고    scopus 로고
    • Complications of laparoscopy
    • Joshi GP. Complications of laparoscopy. Anesthesiol Clin North Am 2001;19:89-105.
    • (2001) Anesthesiol Clin North Am , vol.19 , pp. 89-105
    • Joshi, G.P.1
  • 4
    • 0024461731 scopus 로고
    • Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position
    • Brunel W, Coleman DL, Schwartz DE, et al. Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position. Chest 1989;96:1043-5.
    • (1989) Chest , vol.96 , pp. 1043-1045
    • Brunel, W.1    Coleman, D.L.2    Schwartz, D.E.3
  • 5
    • 0028322076 scopus 로고
    • Women are at greater risk than men for malpositioning of the endotracheal tube after emergent intubation
    • Schwartz DE, Lieberman JA, Cohen NH. Women are at greater risk than men for malpositioning of the endotracheal tube after emergent intubation. Crit Care Med 1994;22:1127-31.
    • (1994) Crit Care Med , vol.22 , pp. 1127-1131
    • Schwartz, D.E.1    Lieberman, J.A.2    Cohen, N.H.3
  • 6
    • 0027372598 scopus 로고
    • The Australian Incident Monitoring Study. The stethoscope: Applications and limitations - An analysis of 2000 incident reports
    • Klepper ID, Webb RK, Van der Walt JH, et al. The Australian Incident Monitoring Study. The stethoscope: applications and limitations - an analysis of 2000 incident reports. Anesth Intensive Care 1993;21:575-8.
    • (1993) Anesth Intensive Care , vol.21 , pp. 575-578
    • Klepper, I.D.1    Webb, R.K.2    Van Der Walt, J.H.3
  • 7
    • 0028850510 scopus 로고
    • Reliability of auscultation of bilateral breath sounds in confirming endotracheal tube position
    • Sugiyama K, Yokoyama K. Reliability of auscultation of bilateral breath sounds in confirming endotracheal tube position. Anesthesiology 1995;83:1373.
    • (1995) Anesthesiology , vol.83 , pp. 1373
    • Sugiyama, K.1    Yokoyama, K.2
  • 8
    • 0027672058 scopus 로고
    • The Australian Incident Monitoring Study. Which monitor? An analysis of 2000 incident reports
    • Webb RK, van der Walt JH, Runciman WB, et al. The Australian Incident Monitoring Study. Which monitor? An analysis of 2000 incident reports. Anesth Intensive Care 1993;21:529-42.
    • (1993) Anesth Intensive Care , vol.21 , pp. 529-542
    • Webb, R.K.1    Van Der Walt, J.H.2    Runciman, W.B.3
  • 9
    • 0023377973 scopus 로고
    • Now that we have pulse oximeters and capnographs, we don't need precordial and esophageal stethoscopes
    • Webster TA. Now that we have pulse oximeters and capnographs, we don't need precordial and esophageal stethoscopes. J Clin Monit 1987;3:191-2.
    • (1987) J Clin Monit , vol.3 , pp. 191-192
    • Webster, T.A.1
  • 10
    • 0019811897 scopus 로고
    • End-tidal carbon dioxide during thoracotomy. Its relation to blood level in adults and children
    • Heneghan CP, Scallan MJ, Branthwaite MA. End-tidal carbon dioxide during thoracotomy. Its relation to blood level in adults and children. Anaesthesia 1981;36:1017-21.
    • (1981) Anaesthesia , vol.36 , pp. 1017-1021
    • Heneghan, C.P.1    Scallan, M.J.2    Branthwaite, M.A.3
  • 11
    • 0026612240 scopus 로고
    • 2 and pulmonary blood flow after bronchial occlusion in dogs
    • 2 and pulmonary blood flow after bronchial occlusion in dogs. Can J Anaesth 1992;39:184-91.
    • (1992) Can J Anaesth , vol.39 , pp. 184-191
    • Johnson, D.H.1    Chang, P.C.2    Hurst, T.S.3
  • 12
    • 0020628816 scopus 로고
    • Video stethoscope - A simple method for assuring continuous bilateral lung ventilation during anesthesia
    • Huang KC, Kraman SS, Wright BD. Video stethoscope - a simple method for assuring continuous bilateral lung ventilation during anesthesia. Anesth Analg 1983;62:586-9.
    • (1983) Anesth Analg , vol.62 , pp. 586-589
    • Huang, K.C.1    Kraman, S.S.2    Wright, B.D.3
  • 13
    • 0029862169 scopus 로고    scopus 로고
    • Computer-assisted auscultation of a bronchopleurocutaneous fistula during general anesthesia
    • Manecke GR Jr, Hartman AR, Poppers PJ. Computer-assisted auscultation of a bronchopleurocutaneous fistula during general anesthesia. Anesth Analg 1996;83:880-2.
    • (1996) Anesth Analg , vol.83 , pp. 880-882
    • Manecke Jr., G.R.1    Hartman, A.R.2    Poppers, P.J.3
  • 14
    • 0027159597 scopus 로고
    • Continuous spirometry for detection of double-lumen endobronchial tube displacement
    • Bardoczky GI, Levarlet M, Englelman E, deFrancquen P. Continuous spirometry for detection of double-lumen endobronchial tube displacement. Br J Anaesth 1993;70:499-502.
    • (1993) Br J Anaesth , vol.70 , pp. 499-502
    • Bardoczky, G.I.1    Levarlet, M.2    Englelman, E.3    DeFrancquen, P.4
  • 15
    • 0037299053 scopus 로고    scopus 로고
    • Acoustic reflectometry detection of an endobronchial intubation in a patient with equal breath sounds
    • Raphael DT, Lee H. Acoustic reflectometry detection of an endobronchial intubation in a patient with equal breath sounds. J Clin Anesth 2003;15:41-7.
    • (2003) J Clin Anesth , vol.15 , pp. 41-47
    • Raphael, D.T.1    Lee, H.2
  • 16
    • 0036896525 scopus 로고    scopus 로고
    • Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients
    • Raphael DT, Benbassat M, Arnaudov D, et al. Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients. Anesthesiology 2002;97:1371-7.
    • (2002) Anesthesiology , vol.97 , pp. 1371-1377
    • Raphael, D.T.1    Benbassat, M.2    Arnaudov, D.3
  • 19
    • 0021646088 scopus 로고
    • Analysis and automatic classification of breath sounds
    • Cohen A, Landsberg D. Analysis and automatic classification of breath sounds. IEEE Trans Biomed Engl 1984;31:585-90.
    • (1984) IEEE Trans Biomed Engl , vol.31 , pp. 585-590
    • Cohen, A.1    Landsberg, D.2
  • 20
    • 0026107525 scopus 로고
    • Acoustic transmission of the respiratory system using speech stimulation
    • Cohen A, Berstein AD. Acoustic transmission of the respiratory system using speech stimulation. IEEE Trans Biomed Engl 1991;38:126-32.
    • (1991) IEEE Trans Biomed Engl , vol.38 , pp. 126-132
    • Cohen, A.1    Berstein, A.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.