메뉴 건너뛰기




Volumn 55, Issue 3, 2008, Pages 172-176

Case report: Vibration response imaging findings following inadvertent esophageal intubation

Author keywords

[No Author keywords available]

Indexed keywords

FENTANYL; PROPOFOL; ROCURONIUM;

EID: 41349121176     PISSN: 0832610X     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03016092     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 0000427105 scopus 로고    scopus 로고
    • Airway management
    • Miller RD Ed, 5th ed. New York: Churchill Livingstone Inc
    • th ed. New York: Churchill Livingstone Inc.; 2000: 1414-51.
    • (2000) Anaesthesia , pp. 1414-1451
    • Stone, D.J.1    Gal, T.J.2
  • 2
    • 23944466588 scopus 로고    scopus 로고
    • Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes
    • O'Connor CJ, Mansy H, Balk RA, Tuman KJ, Sandler RH. Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes. Anesth Analg 2005; 101: 735-9.
    • (2005) Anesth Analg , vol.101 , pp. 735-739
    • O'Connor, C.J.1    Mansy, H.2    Balk, R.A.3    Tuman, K.J.4    Sandler, R.H.5
  • 3
    • 0026663046 scopus 로고
    • Reliability of auscultation in positioning of double-lumen endobronchial tubes
    • Alliaume B, Coddens J, Deloof T. Reliability of auscultation in positioning of double-lumen endobronchial tubes. Can J Anaesth 1992; 39: 687-90.
    • (1992) Can J Anaesth , vol.39 , pp. 687-690
    • Alliaume, B.1    Coddens, J.2    Deloof, T.3
  • 4
    • 0027978635 scopus 로고
    • Oesophageal intubation can be undetected by auscultation of the chest
    • Andersen KH, Schultz-Lebahn T. Oesophageal intubation can be undetected by auscultation of the chest. Acta Anaesthesiol Scand 1994; 38: 580-2.
    • (1994) Acta Anaesthesiol Scand , vol.38 , pp. 580-582
    • Andersen, K.H.1    Schultz-Lebahn, T.2
  • 5
    • 0032946318 scopus 로고    scopus 로고
    • The assessment of four different methods to verify tracheal tube placement in the critical care setting
    • Knapp S, Kofler J, Stoiser B, et al. The assessment of four different methods to verify tracheal tube placement in the critical care setting. Anesth Analg 1999; 88: 766-70.
    • (1999) Anesth Analg , vol.88 , pp. 766-770
    • Knapp, S.1    Kofler, J.2    Stoiser, B.3
  • 6
    • 3042521169 scopus 로고    scopus 로고
    • Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children
    • Verghese ST, Hannallah RS, Slack MC, Cross RR, Patel KM. Auscultation of bilateral breath sounds does not rule out endobronchial intubation in children. Anesth Analg 2004; 99: 56-8.
    • (2004) Anesth Analg , vol.99 , pp. 56-58
    • Verghese, S.T.1    Hannallah, R.S.2    Slack, M.C.3    Cross, R.R.4    Patel, K.M.5
  • 7
    • 25144448296 scopus 로고    scopus 로고
    • Acoustic reflectometry esophageal profiles minimally affected by massive gas ventilation
    • Raphael DT, Crookes P, Arnaudov D, Benbassat M. Acoustic reflectometry esophageal profiles minimally affected by massive gas ventilation. Am J Emerg Med 2005; 23: 747-53.
    • (2005) Am J Emerg Med , vol.23 , pp. 747-753
    • Raphael, D.T.1    Crookes, P.2    Arnaudov, D.3    Benbassat, M.4
  • 8
    • 0033032727 scopus 로고    scopus 로고
    • Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation?
    • Sugiyama K, Yokoyama K, Satoh K, Nishihara M, Yoshitomi T. Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation? Anesth Analg 1999; 88: 1380-3.
    • (1999) Anesth Analg , vol.88 , pp. 1380-1383
    • Sugiyama, K.1    Yokoyama, K.2    Satoh, K.3    Nishihara, M.4    Yoshitomi, T.5
  • 9
    • 0025223660 scopus 로고
    • Endotracheal tube confirmation with colorimetric CO2 detectors
    • Menegazzi JJ, Heller MB. Endotracheal tube confirmation with colorimetric CO2 detectors. Anesth Analg 1990; 71: 441-2.
    • (1990) Anesth Analg , vol.71 , pp. 441-442
    • Menegazzi, J.J.1    Heller, M.B.2
  • 10
    • 33947655985 scopus 로고    scopus 로고
    • Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode
    • Dellinger RP, Jean S, Cinel I, et al. Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode. Crit Care 2007; 11: R26.
    • (2007) Crit Care , vol.11
    • Dellinger, R.P.1    Jean, S.2    Cinel, I.3
  • 11
    • 38049089433 scopus 로고    scopus 로고
    • Dynamic visualization of lung sounds with a vibration response device: A case series
    • doi: 10.1159/000103558
    • Dellinger RP, Parrillo JE, Kushnir A, Rossi M, Kushnir I. Dynamic visualization of lung sounds with a vibration response device: a case series. Respiration 2007; doi: 10.1159/000103558.
    • (2007) Respiration
    • Dellinger, R.P.1    Parrillo, J.E.2    Kushnir, A.3    Rossi, M.4    Kushnir, I.5
  • 12
    • 85036951956 scopus 로고    scopus 로고
    • Acoustic monitoring of one-lung ventilation with vibration response imaging
    • Cinel I, Jean S, Gratz I, Deal E, Tay C, Littman J. Acoustic monitoring of one-lung ventilation with vibration response imaging. Crit Care 2007; 11(Suppl 2): P202.
    • (2007) Crit Care , vol.11 , Issue.SUPPL. 2
    • Cinel, I.1    Jean, S.2    Gratz, I.3    Deal, E.4    Tay, C.5    Littman, J.6
  • 13
    • 33845670411 scopus 로고    scopus 로고
    • Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation
    • Tejman-Yarden S, Lederman D, Eilig I, et al. Acoustic monitoring of double-lumen ventilated lungs for the detection of selective unilateral lung ventilation. Anesth Analg 2006; 1003: 1489-93.
    • (2006) Anesth Analg , vol.1003 , pp. 1489-1493
    • Tejman-Yarden, S.1    Lederman, D.2    Eilig, I.3
  • 14
    • 33748800710 scopus 로고    scopus 로고
    • Tracheobronchial foreign body aspiration in children - diagnostic value of symptoms and signs
    • Tomaske M, Gerber AC, Stocker S, Weiss M. Tracheobronchial foreign body aspiration in children - diagnostic value of symptoms and signs. Swiss Med Wkly 2006; 136: 533-8.
    • (2006) Swiss Med Wkly , vol.136 , pp. 533-538
    • Tomaske, M.1    Gerber, A.C.2    Stocker, S.3    Weiss, M.4
  • 15
    • 40649110922 scopus 로고    scopus 로고
    • ben-Dov I. Breath sound distribution images of patients with pneumonia and pleural effusion
    • Mor R, Kushnir I, Meyer JJ, Ekstein J, ben-Dov I. Breath sound distribution images of patients with pneumonia and pleural effusion. Respir Care 2007; 52: 1753-60.
    • (2007) Respir Care , vol.52 , pp. 1753-1760
    • Mor, R.1    Kushnir, I.2    Meyer, J.J.3    Ekstein, J.4
  • 16
    • 34547700092 scopus 로고    scopus 로고
    • Dynamic visualization of breath sound distribution in suspected foreign body aspiration: A pediatric case series
    • Bentur L, Livnat G, Husein D, Pollack S, Rotschild M. Dynamic visualization of breath sound distribution in suspected foreign body aspiration: a pediatric case series. Journal of Bronchology 2007; 14: 156-61.
    • (2007) Journal of Bronchology , vol.14 , pp. 156-161
    • Bentur, L.1    Livnat, G.2    Husein, D.3    Pollack, S.4    Rotschild, M.5
  • 18
    • 34547698944 scopus 로고    scopus 로고
    • Dynamic visualization of breath sound distribution: Can we see the voices?
    • Kramer MR. Dynamic visualization of breath sound distribution: can we see the voices? Journal of Bronchology 2007; 14: 142-3.
    • (2007) Journal of Bronchology , vol.14 , pp. 142-143
    • MR, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.