메뉴 건너뛰기




Volumn 92, Issue 2, 2004, Pages 195-201

Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation

Author keywords

Complications, hypoxaemia, Complications, tube, malposition; Equipment, double lumen tube; Thoracic; Ventilation, one lung

Indexed keywords

OXYGEN;

EID: 0742272007     PISSN: 00070912     EISSN: None     Source Type: Journal    
DOI: 10.1093/bja/aeh055     Document Type: Article
Times cited : (94)

References (26)
  • 1
    • 0036252612 scopus 로고    scopus 로고
    • Prediction of arterial oxygen tension during one-lung ventilation: Analysis of preoperative and intraoperative variables
    • Guenoun T, Journois D, Silleran-Chassany J, et al. Prediction of arterial oxygen tension during one-lung ventilation: analysis of preoperative and intraoperative variables. J Cardiothorac Vasc Anesth 2002; 16: 199-203
    • (2002) J. Cardiothorac. Vasc. Anesth. , vol.16 , pp. 199-203
    • Guenoun, T.1    Journois, D.2    Silleran-Chassany, J.3
  • 2
    • 0027422263 scopus 로고
    • A quality improvement study of the placement and complications of double-lumen endobronchial tubes
    • Hurford WE, Alfille PH. A quality improvement study of the placement and complications of double-lumen endobronchial tubes. J Cardiothorac Vasc Anesth 1993; 7: 517-20
    • (1993) J. Cardiothorac. Vasc. Anesth. , vol.7 , pp. 517-520
    • Hurford, W.E.1    Alfille, P.H.2
  • 3
    • 0027104017 scopus 로고
    • Predicting arterial oxygenation during one-lung anaesthesia
    • Slinger P, Suissa S, Triolet W. Predicting arterial oxygenation during one-lung anaesthesia. Can J Anaesth 1992; 39: 1030-5
    • (1992) Can. J. Anaesth. , vol.39 , pp. 1030-1035
    • Slinger, P.1    Suissa, S.2    Triolet, W.3
  • 4
  • 5
    • 0023448623 scopus 로고
    • The use of ventilation/perfusion lung scans to predict oxygenation during one-lung anesthesia
    • Hurford WE, Kolker AC, Strauss HW. The use of ventilation/perfusion lung scans to predict oxygenation during one-lung anesthesia. Anesthesiology 1987; 67: 841-4
    • (1987) Anesthesiology , vol.67 , pp. 841-844
    • Hurford, W.E.1    Kolker, A.C.2    Strauss, H.W.3
  • 6
    • 0031913886 scopus 로고    scopus 로고
    • Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: A prospective study
    • Klein U, Karzai W, Bloos F, et al. Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study. Anesthesiology 1998; 88: 346-50
    • (1998) Anesthesiology , vol.88 , pp. 346-350
    • Klein, U.1    Karzai, W.2    Bloos, F.3
  • 7
    • 0030843302 scopus 로고    scopus 로고
    • The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning
    • Desiderio DP, Burt M, Kolker AC, et al. The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning. J Cardiothorac Vasc Anesth 1997; 11: 595-8
    • (1997) J. Cardiothorac. Vasc. Anesth. , vol.11 , pp. 595-598
    • Desiderio, D.P.1    Burt, M.2    Kolker, A.C.3
  • 8
    • 0029856033 scopus 로고    scopus 로고
    • Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker
    • Campos JH, Reasoner DK, Moyers JR. Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker. Anesth Analg 1996; 83: 1268-72
    • (1996) Anesth. Analg. , vol.83 , pp. 1268-1272
    • Campos, J.H.1    Reasoner, D.K.2    Moyers, J.R.3
  • 9
    • 0037223284 scopus 로고    scopus 로고
    • A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker
    • Campos JH, Kernstine KH. A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker. Anesth Analg 2003; 96: 283-9
    • (2003) Anesth. Analg. , vol.96 , pp. 283-289
    • Campos, J.H.1    Kernstine, K.H.2
  • 10
    • 0000091955 scopus 로고
    • Low resistance double-lumen endobronchial tubes
    • Robertshaw FL. Low resistance double-lumen endobronchial tubes. Br J Anaesth 1962; 34: 576-9
    • (1962) Br. J. Anaesth. , vol.34 , pp. 576-579
    • Robertshaw, F.L.1
  • 11
    • 0029998807 scopus 로고    scopus 로고
    • Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    • Brodsky JB, Macario A, Mark JBD. Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes. Anesth Analg 1996; 82: 861-4
    • (1996) Anesth. Analg. , vol.82 , pp. 861-864
    • Brodsky, J.B.1    Macario, A.2    Mark, J.B.D.3
  • 12
    • 0031003952 scopus 로고    scopus 로고
    • Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter
    • Hannallah M, Benumof JL, Silverman PM, Kelly LC, Lea D. Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter. J Cardiothorac Vasc Anesth 1997; 11: 168-71
    • (1997) J. Cardiothorac. Vasc. Anesth. , vol.11 , pp. 168-171
    • Hannallah, M.1    Benumof, J.L.2    Silverman, P.M.3    Kelly, L.C.4    Lea, D.5
  • 14
    • 0034100138 scopus 로고    scopus 로고
    • The incidence of right upper-lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery
    • Campos JH, Massa FC, Kernstine KH. The incidence of right upper-lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery. Anesth Analg 2000; 90: 535-40
    • (2000) Anesth. Analg. , vol.90 , pp. 535-540
    • Campos, J.H.1    Massa, F.C.2    Kernstine, K.H.3
  • 15
    • 0024441076 scopus 로고
    • Fiberoptic bronchoscopic positioning of double-lumen tubes
    • Slinger PD. Fiberoptic bronchoscopic positioning of double-lumen tubes. J Cardiothorac Anesth 1989; 3: 486-96
    • (1989) J. Cardiothorac. Anesth. , vol.3 , pp. 486-496
    • Slinger, P.D.1
  • 16
    • 0025364914 scopus 로고
    • Effects of anaesthetics on the pulmonary circulation
    • Eisenkraft JB. Effects of anaesthetics on the pulmonary circulation. Br J Anaesth 1990; 65: 63-78
    • (1990) Br. J. Anaesth. , vol.65 , pp. 63-78
    • Eisenkraft, J.B.1
  • 17
    • 0033980913 scopus 로고    scopus 로고
    • Two-lung and one-lung ventilation in patients with chronic obstructive pulmonary disease: The effects of position and F(IO)2
    • Bardoczky GI, Szegedi LL, d'Hollander AA, Moures JM, de Francquen P, Yernault JC. Two-lung and one-lung ventilation in patients with chronic obstructive pulmonary disease: the effects of position and F(IO)2. Anesth Anaig 2000; 90: 35-41
    • (2000) Anesth. Analg. , vol.90 , pp. 35-41
    • Bardoczky, G.I.1    Szegedi, L.L.2    d'Hollander, A.A.3    Moures, J.M.4    de Francquen, P.5    Yernault, J.C.6
  • 18
    • 0020042170 scopus 로고
    • One lung ventilation: Which lung should be PEEPed?
    • Benumof JL. One lung ventilation: which lung should be PEEPed? Anesthesiology 1982; 56: 161-163
    • (1982) Anesthesiology , vol.56 , pp. 161-163
    • Benumof, J.L.1
  • 20
    • 0030977921 scopus 로고    scopus 로고
    • Video-assisted thoracoscopic volume reduction surgery in patients with diffuse pulmonary enphysema: Gas exchange and anesthesiological management
    • Zollinger A, Zaugg M, Weder W, et al. Video-assisted thoracoscopic volume reduction surgery in patients with diffuse pulmonary enphysema: gas exchange and anesthesiological management. Anesth Analg 1997; 84: 845-51
    • (1997) Anesth. Analg. , vol.84 , pp. 845-851
    • Zollinger, A.1    Zaugg, M.2    Weder, W.3
  • 24
    • 0036841163 scopus 로고    scopus 로고
    • Current techniques for perioperative lung isolation in adults
    • Campos JH. Current techniques for perioperative lung isolation in adults. Anesthesiology 2002; 97: 1295-301
    • (2002) Anesthesiology , vol.97 , pp. 1295-1301
    • Campos, J.H.1
  • 25
    • 0027518606 scopus 로고
    • Pro: One-lung ventilation is best accomplished with the Univent endotracheal tube
    • Gayes JM. Pro: one-lung ventilation is best accomplished with the Univent endotracheal tube. J Cardiothorac Vasc Anesth 1993; 7: 103-7
    • (1993) J. Cardiothorac. Vasc. Anesth. , vol.7 , pp. 103-107
    • Gayes, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.