메뉴 건너뛰기




Volumn 86, Issue 4, 2008, Pages 857-864

A novel surface treatment for porous metallic implants that improves the rate of bony ongrowth

Author keywords

Bone ingrowth; Hydroxyapatite; Phosphonate; Porous coating; Titanium alloy

Indexed keywords

AMINES; APATITE; CLADDING (COATING); COST EFFECTIVENESS; HYDROXYAPATITE; TITANIUM; TITANIUM ALLOYS; TITANIUM OXIDES;

EID: 50149122610     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.31651     Document Type: Article
Times cited : (24)

References (35)
  • 1
    • 0942301374 scopus 로고    scopus 로고
    • Cementless acetabular fixation at fifteen years. A comparison with the same surgeon's results following acetabular fixation with cement
    • Gaffey JL, Callaghan JJ, Pedersen DR, Goetz DD, Sullivan PM, Johnston RC. Cementless acetabular fixation at fifteen years. A comparison with the same surgeon's results following acetabular fixation with cement. J Bone Joint Surg Am 2004;86-A:257-261.
    • (2004) J Bone Joint Surg Am , vol.86-A , pp. 257-261
    • Gaffey, J.L.1    Callaghan, J.J.2    Pedersen, D.R.3    Goetz, D.D.4    Sullivan, P.M.5    Johnston, R.C.6
  • 2
    • 33645058927 scopus 로고    scopus 로고
    • Uncemented total hip arthroplasty for primary osteoarthritis in young patients: A mid-to long-term follow-up study from the Finnish Arthroplasty Register
    • Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Uncemented total hip arthroplasty for primary osteoarthritis in young patients: A mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop 2006;77:57-70.
    • (2006) Acta Orthop , vol.77 , pp. 57-70
    • Eskelinen, A.1    Remes, V.2    Helenius, I.3    Pulkkinen, P.4    Nevalainen, J.5    Paavolainen, P.6
  • 3
    • 33645279522 scopus 로고    scopus 로고
    • Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem: Results at a minimum of 10 years' follow-up in 104 hips
    • Boden H, Salemyr M, Skoldenberg O, Ahl T, Adolphson P. Total hip arthroplasty with an uncemented hydroxyapatite-coated tapered titanium stem: Results at a minimum of 10 years' follow-up in 104 hips. J Orthop Sci 2006;11:175-179.
    • (2006) J Orthop Sci , vol.11 , pp. 175-179
    • Boden, H.1    Salemyr, M.2    Skoldenberg, O.3    Ahl, T.4    Adolphson, P.5
  • 5
    • 33645677649 scopus 로고    scopus 로고
    • Additive enhancement of implant fixation following combined treatment with rhTGF-β2 and rhBMP-2 in a canine model
    • Sumner DR, Turner TM, Urban RM, Virdi AS, Inoue N. Additive enhancement of implant fixation following combined treatment with rhTGF-β2 and rhBMP-2 in a canine model. J Bone Joint Surg Am 2006;88:806-817.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 806-817
    • Sumner, D.R.1    Turner, T.M.2    Urban, R.M.3    Virdi, A.S.4    Inoue, N.5
  • 6
    • 0028230087 scopus 로고
    • The influence of a hydroxyapatite and tricalcium-phosphate coating on bone growth into titanium fiber-metal implants
    • Tisdel CL, Goldberg VM, Parr JA, Bensusan JS, Staikoff LS, Stevenson S. The influence of a hydroxyapatite and tricalcium-phosphate coating on bone growth into titanium fiber-metal implants. J Bone Joint Surg Am 1994;76:159-171.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 159-171
    • Tisdel, C.L.1    Goldberg, V.M.2    Parr, J.A.3    Bensusan, J.S.4    Staikoff, L.S.5    Stevenson, S.6
  • 7
    • 0029583841 scopus 로고
    • Effects of hydroxyapatite tricalcium phosphate coating and intracancellous placement on bone ingrowth in titanium fibermetal implants
    • Dean JC, Tisdel CL, Goldberg VM, Parr J, Davy D, Stevenson S. Effects of hydroxyapatite tricalcium phosphate coating and intracancellous placement on bone ingrowth in titanium fibermetal implants. J Arthroplasty 1995;10:830-838.
    • (1995) J Arthroplasty , vol.10 , pp. 830-838
    • Dean, J.C.1    Tisdel, C.L.2    Goldberg, V.M.3    Parr, J.4    Davy, D.5    Stevenson, S.6
  • 8
    • 0035811269 scopus 로고    scopus 로고
    • Comparison of plasma-sprayed hydroxyapatite coatings and hydroxyapatite/tricalcium phosphate composite coatings: In vivo study
    • Lee TM, Wang BC, Yang YC, Chang E, Yang CY. Comparison of plasma-sprayed hydroxyapatite coatings and hydroxyapatite/tricalcium phosphate composite coatings: In vivo study. J Biomed Mater Res 2001;55:360-367.
    • (2001) J Biomed Mater Res , vol.55 , pp. 360-367
    • Lee, T.M.1    Wang, B.C.2    Yang, Y.C.3    Chang, E.4    Yang, C.Y.5
  • 9
    • 0036788563 scopus 로고    scopus 로고
    • Comparison of hydroxyapatite and hydroxyapatite tricalcium-phosphate coatings
    • Jinno T, Davy DT, Goldberg VM. Comparison of hydroxyapatite and hydroxyapatite tricalcium-phosphate coatings. J Arthroplasty 2002;17:902-909.
    • (2002) J Arthroplasty , vol.17 , pp. 902-909
    • Jinno, T.1    Davy, D.T.2    Goldberg, V.M.3
  • 10
    • 1642343895 scopus 로고    scopus 로고
    • Effect of hydroxyapatite/tricalcium- phosphate coating on osseointegration of plasma-sprayed titanium alloy implants
    • Stewart M, Welter JF, Goldberg VM. Effect of hydroxyapatite/tricalcium- phosphate coating on osseointegration of plasma-sprayed titanium alloy implants. J Biomed Mater Res A 2004;69:1-10.
    • (2004) J Biomed Mater Res A , vol.69 , pp. 1-10
    • Stewart, M.1    Welter, J.F.2    Goldberg, V.M.3
  • 11
    • 23644451672 scopus 로고    scopus 로고
    • Results of a hydroxyapatite-coated (Furlong) total hip replacement: A 13- to 15-year follow-up
    • Shetty AA, Slack R, Tindall A, James KD, Rand C. Results of a hydroxyapatite-coated (Furlong) total hip replacement: A 13- to 15-year follow-up. J Bone Joint Surg Br 2005;87:1050-1054.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 1050-1054
    • Shetty, A.A.1    Slack, R.2    Tindall, A.3    James, K.D.4    Rand, C.5
  • 13
    • 0036789484 scopus 로고    scopus 로고
    • A retrospective clinical and radiographic review of 173 hydroxyapatite-coated screw cups with 5- to 10-year follow-up, showing low revision rates for fixation failure
    • Mann CJ, McNally S, Taylor E, Shepperd JA. A retrospective clinical and radiographic review of 173 hydroxyapatite-coated screw cups with 5- to 10-year follow-up, showing low revision rates for fixation failure. J Arthroplasty 2002;17:851-855.
    • (2002) J Arthroplasty , vol.17 , pp. 851-855
    • Mann, C.J.1    McNally, S.2    Taylor, E.3    Shepperd, J.A.4
  • 14
    • 0035408389 scopus 로고    scopus 로고
    • Synovitis subsequent to total-hip arthroplasty with and without hydroxyapatite coatings: A study in dogs
    • Anderson GI, Orlando K, Waddell JP. Synovitis subsequent to total-hip arthroplasty with and without hydroxyapatite coatings: A study in dogs. Vet Surg 2001;30:311-318.
    • (2001) Vet Surg , vol.30 , pp. 311-318
    • Anderson, G.I.1    Orlando, K.2    Waddell, J.P.3
  • 15
    • 0036327602 scopus 로고    scopus 로고
    • Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties
    • Lai KA, Shen WJ, Chen CH, Yang CY, Hu WP, Chang GL. Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties. J Bone Joint Surg Br 2002;84:641-646.
    • (2002) J Bone Joint Surg Br , vol.84 , pp. 641-646
    • Lai, K.A.1    Shen, W.J.2    Chen, C.H.3    Yang, C.Y.4    Hu, W.P.5    Chang, G.L.6
  • 16
    • 0036121672 scopus 로고    scopus 로고
    • Failure of HA coating on a grit-blasted acetabular cup: 155 patients followed for 7-10 years
    • Reikeras O, Gunderson RB. Failure of HA coating on a grit-blasted acetabular cup: 155 patients followed for 7-10 years. Acta Orthop Scand 2002;73:104-108.
    • (2002) Acta Orthop Scand , vol.73 , pp. 104-108
    • Reikeras, O.1    Gunderson, R.B.2
  • 17
    • 0034059995 scopus 로고    scopus 로고
    • Chemical gradient in plasma-sprayed HA coatings
    • Wen J, Leng Y, Chen J, Zhang C. Chemical gradient in plasma-sprayed HA coatings. Biomaterials 2000;21:1339-1343.
    • (2000) Biomaterials , vol.21 , pp. 1339-1343
    • Wen, J.1    Leng, Y.2    Chen, J.3    Zhang, C.4
  • 21
    • 0035909156 scopus 로고    scopus 로고
    • Self-assembly and bonding of alkanephosphonic acids on the native oxide surface of titanium
    • Gawalt ES, Avaltroni MJ, Koch N, Schwartz J. Self-assembly and bonding of alkanephosphonic acids on the native oxide surface of titanium. Langmuir 2001;17:5736-5738.
    • (2001) Langmuir , vol.17 , pp. 5736-5738
    • Gawalt, E.S.1    Avaltroni, M.J.2    Koch, N.3    Schwartz, J.4
  • 22
    • 3042682484 scopus 로고    scopus 로고
    • Self-assembled monolayers of α,ω-diphosphonic acids on Ti enable complete or spatially controlled surface derivatization
    • Danahy MP, Avaltroni MJ, Midwood KS, Schwarz-bauer JE, Schwartz J. Self-assembled monolayers of α,ω-diphosphonic acids on Ti enable complete or spatially controlled surface derivatization. Langmuir 2004;20:5333-5337.
    • (2004) Langmuir , vol.20 , pp. 5333-5337
    • Danahy, M.P.1    Avaltroni, M.J.2    Midwood, K.S.3    Schwarz-bauer, J.E.4    Schwartz, J.5
  • 23
    • 11144280456 scopus 로고    scopus 로고
    • In vivo study of the effect of RGD treatment on bone ongrowth on press-fit titanium alloy implants
    • EImengaard B, Bechtold JE, Soballe K. In vivo study of the effect of RGD treatment on bone ongrowth on press-fit titanium alloy implants. Biomaterials 2005;26:3521-3526.
    • (2005) Biomaterials , vol.26 , pp. 3521-3526
    • EImengaard, B.1    Bechtold, J.E.2    Soballe, K.3
  • 25
    • 0032837995 scopus 로고    scopus 로고
    • Integrin subunits responsible for adhesion of human osteoblast-like cells to biomimetic peptide surfaces
    • Rezania A, Healy KE. Integrin subunits responsible for adhesion of human osteoblast-like cells to biomimetic peptide surfaces. J Orthop Res 1999;17:615-623.
    • (1999) J Orthop Res , vol.17 , pp. 615-623
    • Rezania, A.1    Healy, K.E.2
  • 26
    • 50149114023 scopus 로고    scopus 로고
    • Self-assembled monolayer films of phosphonates (SAMPs) is an in vivo stable platform for bonding Arg-Gly-Asp (RGD) to Ti-6Al-4V
    • Unpublished
    • Heijink A, Sibonga J, Schwartz J, Crowder KN, Zobitz M, Lutz G, An K-N. Self-assembled monolayer films of phosphonates (SAMPs) is an in vivo stable platform for bonding Arg-Gly-Asp (RGD) to Ti-6Al-4V. J Biomed Mater Res A. Unpublished.
    • J Biomed Mater Res A
    • Heijink, A.1    Sibonga, J.2    Schwartz, J.3    Crowder, K.N.4    Zobitz, M.5    Lutz, G.6    An, K.-N.7
  • 27
    • 0345733895 scopus 로고    scopus 로고
    • Bonding self-assembled, compact organophosphonate monolayers to the native oxide surface of silicon
    • Hanson EL, Schwartz J, Nickel B, Koch N, Danisman MF. Bonding self-assembled, compact organophosphonate monolayers to the native oxide surface of silicon. J Am Chem Soc 2003;125:16074-16080.
    • (2003) J Am Chem Soc , vol.125 , pp. 16074-16080
    • Hanson, E.L.1    Schwartz, J.2    Nickel, B.3    Koch, N.4    Danisman, M.F.5
  • 31
    • 0036908789 scopus 로고    scopus 로고
    • Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings
    • Hacking SA, Tanzer M, Harvey EJ, Krygier JJ, Bobyn JD. Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings. Clin Orthop Relat Res 2002;405:24-38.
    • (2002) Clin Orthop Relat Res , vol.405 , pp. 24-38
    • Hacking, S.A.1    Tanzer, M.2    Harvey, E.J.3    Krygier, J.J.4    Bobyn, J.D.5
  • 32
    • 0032820817 scopus 로고    scopus 로고
    • Calcium sulfate- and calcium phosphate-based bone substitutes. Mimicry of the mineral phase of bone
    • Tay BK, Patel VV, Bradford DS. Calcium sulfate- and calcium phosphate-based bone substitutes. Mimicry of the mineral phase of bone. Orthop Clin North Am 1999;30:615-623.
    • (1999) Orthop Clin North Am , vol.30 , pp. 615-623
    • Tay, B.K.1    Patel, V.V.2    Bradford, D.S.3
  • 33
    • 0028796086 scopus 로고
    • Mechanical and histological evaluation of hydroxyapatite-coated, titanium-coated and grit-blasted surfaces under weight-bearing conditions
    • David A, Eitenmuller J, Muhr G, Pommer A, Bar HF, Ostermann PA, Schildhauer TA. Mechanical and histological evaluation of hydroxyapatite-coated, titanium-coated and grit-blasted surfaces under weight-bearing conditions. Arch Orthop Trauma Surg 1995;114:112-118.
    • (1995) Arch Orthop Trauma Surg , vol.114 , pp. 112-118
    • David, A.1    Eitenmuller, J.2    Muhr, G.3    Pommer, A.4    Bar, H.F.5    Ostermann, P.A.6    Schildhauer, T.A.7
  • 34
    • 0028533742 scopus 로고
    • Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength
    • Hayashi K, Inadome T, Tsumura H, Nakashima Y, Sugioka Y. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. Biomaterials 1994;15:1187-1191.
    • (1994) Biomaterials , vol.15 , pp. 1187-1191
    • Hayashi, K.1    Inadome, T.2    Tsumura, H.3    Nakashima, Y.4    Sugioka, Y.5
  • 35
    • 0027605120 scopus 로고
    • Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants
    • Hayashi K, Inadome T, Mashima T, Sugioka Y. Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants. J Biomed Mater Res 1993;27:557-563.
    • (1993) J Biomed Mater Res , vol.27 , pp. 557-563
    • Hayashi, K.1    Inadome, T.2    Mashima, T.3    Sugioka, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.