메뉴 건너뛰기




Volumn 17, Issue 7, 2002, Pages 902-909

Comparison of hydroxyapatite and hydroxyapatite tricalcium-phosphate coatings

Author keywords

Bone ongrowth; Hydroxyapatite (HA) coating; Hydroxyapatite tricalcium phosphate (HA TCP); Implant fixation; Osseointegration

Indexed keywords

CALCIUM PHOSPHATE; DOXYCYCLINE; HYDROXYAPATITE; TITANIUM;

EID: 0036788563     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1054/arth.2002.34821     Document Type: Article
Times cited : (39)

References (19)
  • 1
    • 0030471506 scopus 로고    scopus 로고
    • Total hip arthroplasty with hydroxyapatite-coated prostheses
    • Jaffe WL, Scott DF: Total hip arthroplasty with hydroxyapatite-coated prostheses. J Bone Joint Surg Am 78:1918, 1996
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1918
    • Jaffe, W.L.1    Scott, D.F.2
  • 2
    • 0033135496 scopus 로고    scopus 로고
    • Improved bone anchorage of hydroxyapatite coated implants compared with tricalcium-phosphate coated implants in trabecular bone in dogs
    • Lind M, Overgaard S, Bunger C, et al: Improved bone anchorage of hydroxyapatite coated implants compared with tricalcium-phosphate coated implants in trabecular bone in dogs. Biomaterials 20:803, 1999
    • (1999) Biomaterials , vol.20 , pp. 803
    • Lind, M.1    Overgaard, S.2    Bunger, C.3
  • 3
    • 0003034298 scopus 로고
    • Substrate surface dissolution and interfacial biological mineralization
    • Davies JE (ed). University of Toronto Press, Toronto
    • LeGeros RZ, Orly I, Gregoire M, et al: Substrate surface dissolution and interfacial biological mineralization. p. 77. In Davies JE (ed): The bone-biomaterial interface. University of Toronto Press, Toronto, 1991
    • (1991) The bone-biomaterial interface , pp. 77
    • LeGeros, R.Z.1    Orly, I.2    Gregoire, M.3
  • 4
    • 0009604392 scopus 로고
    • Biologic profile of calcium-phosphate coatings
    • Davies JE (ed). University of Toronto Press, Toronto
    • Kay JF, Cook SD: Biologic profile of calcium-phosphate coatings. p. 89. In Davies JE (ed): The bonebiomaterial interface. University of Toronto Press, Toronto, 1991
    • (1991) The bone-biomaterial interface , pp. 89
    • Kay, J.F.1    Cook, S.D.2
  • 5
    • 0028121039 scopus 로고
    • Complications with hydroxyapatite particulate separation in total hip arthroplasty
    • Bloebaum RD, Beeks D, Dorr LD, et al: Complications with hydroxyapatite particulate separation in total hip arthroplasty. Clin Orthop 298:19, 1994
    • (1994) Clin Orthop , vol.298 , pp. 19
    • Bloebaum, R.D.1    Beeks, D.2    Dorr, L.D.3
  • 6
    • 0032701009 scopus 로고    scopus 로고
    • Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis
    • Rokkum M, Brandt M, Bye K, et al: Polyethylene wear, osteolysis and acetabular loosening with an HA-coated hip prosthesis. J Bone Joint Surg Br 81:582, 1999
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 582
    • Rokkum, M.1    Brandt, M.2    Bye, K.3
  • 7
    • 0027590726 scopus 로고
    • Osseointegration of macroporous calcium phosphate ceramics having a different chemical composition
    • Frayssinet P, Trouillet JL, Rouquet N, et al: Osseointegration of macroporous calcium phosphate ceramics having a different chemical composition. Biomaterials 14:423, 1993
    • (1993) Biomaterials , vol.14 , pp. 423
    • Frayssinet, P.1    Trouillet, J.L.2    Rouquet, N.3
  • 8
    • 0029164651 scopus 로고
    • The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model
    • Feighan JE, Goldberg VM, Davy D, et al: The influence of surface-blasting on the incorporation of titanium-alloy implants in a rabbit intramedullary model. J Bone Joint Surg Am 77:1380, 1995
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1380
    • Feighan, J.E.1    Goldberg, V.M.2    Davy, D.3
  • 9
    • 0032190287 scopus 로고    scopus 로고
    • Osseointegration of surface-blasted implants made of titanium alloy and cobalt-chromium alloy in a rabbit intramedullary model
    • Jinno T, Goldberg VM, Davy D, et al: Osseointegration of surface-blasted implants made of titanium alloy and cobalt-chromium alloy in a rabbit intramedullary model. J Biomed Mater Res 42:20, 1998
    • (1998) J Biomed Mater Res , vol.42 , pp. 20
    • Jinno, T.1    Goldberg, V.M.2    Davy, D.3
  • 10
    • 0023499767 scopus 로고
    • Chemical implant fixation using hydroxyl-apatite coatings: The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates
    • Geesink RGT, de Groot K, Klein CPAT: Chemical implant fixation using hydroxyl-apatite coatings: the development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Clin Orthop 225:147, 1987
    • (1987) Clin Orthop , vol.225 , pp. 147
    • Geesink, R.G.T.1    De Groot, K.2    Klein, C.P.A.T.3
  • 11
    • 0001912357 scopus 로고
    • Process application of hydroxylapatite coatings
    • Geesink RGT, Manley MT (eds). Raven Press, New York
    • Serekian P: Process application of hydroxylapatite coatings. p. 81. In Geesink RGT, Manley MT (eds): Hydroxylapatite coatings in orthopaedic surgery. Raven Press, New York, 1993
    • (1993) Hydroxylapatite coatings in orthopaedic surgery , pp. 81
    • Serekian, P.1
  • 12
    • 0029411943 scopus 로고
    • Effect of surface topology on the osseointegration of implant materials in trabecular bone
    • Wong M, Eulenberger J, Schenk R, et al: Effect of surface topology on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res 29:1567, 1995
    • (1995) J Biomed Mater Res , vol.29 , pp. 1567
    • Wong, M.1    Eulenberger, J.2    Schenk, R.3
  • 13
    • 0028533742 scopus 로고
    • Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength
    • Hayashi K, Inadome T, Tsumura H, et al: Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength. Biomaterials 15:1187, 1994
    • (1994) Biomaterials , vol.15 , pp. 1187
    • Hayashi, K.1    Inadome, T.2    Tsumura, H.3
  • 14
    • 0028918271 scopus 로고
    • Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants
    • Inadome T, Hayashi K, Nakashima Y, et al: Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants. J Biomed Mater Res 29:19, 1995
    • (1995) J Biomed Mater Res , vol.29 , pp. 19
    • Inadome, T.1    Hayashi, K.2    Nakashima, Y.3
  • 15
    • 0027686549 scopus 로고
    • The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: The effect of coating thickness
    • Wang BC, Lee TM, Chang E, et al: The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness. J Biomed Mater Res 27:1315, 1993
    • (1993) J Biomed Mater Res , vol.27 , pp. 1315
    • Wang, B.C.1    Lee, T.M.2    Chang, E.3
  • 16
    • 0031195206 scopus 로고    scopus 로고
    • Intramedullary implant of plasma-sprayed hydroxyapatite coating: An interface study
    • Yang CY, Wang BC, Lee TM, et al: Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study. J Biomed Mater Res 36:39, 1997
    • (1997) J Biomed Mater Res , vol.36 , pp. 39
    • Yang, C.Y.1    Wang, B.C.2    Lee, T.M.3
  • 17
    • 0026352034 scopus 로고
    • Hydroxyapatite-coated femoral stems: Histological analysis of components retrieved at autopsy
    • Bauer TW, Geesink RCT, Zimmerman R, et al: Hydroxyapatite-coated femoral stems: histological analysis of components retrieved at autopsy. J Bone Joint Surg Am 73:1439, 1991
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 1439
    • Bauer, T.W.1    Geesink, R.C.T.2    Zimmerman, R.3
  • 18
    • 0034998825 scopus 로고    scopus 로고
    • Hydroxyapatite-coated acetabular components: Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation
    • Tonino A, Oosterbos C, Rahmy A, et al: Hydroxyapatite-coated acetabular components: histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation. J Bone Joint Surg Am 83:817, 2001
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 817
    • Tonino, A.1    Oosterbos, C.2    Rahmy, A.3
  • 19
    • 0030483180 scopus 로고    scopus 로고
    • Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods
    • Overgaard S, Soballe K, Josephsen K, et al: Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods. J Orthop Res 14:888, 1996
    • (1996) J Orthop Res , vol.14 , pp. 888
    • Overgaard, S.1    Soballe, K.2    Josephsen, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.