Volumn 26, Issue 7, 2008, Pages 954-960

Snapshot gradient-recalled echo-planar images of rat brains at long echo time at 9.4 T

Author keywords

Gradient recalled echo planar imaging; GRE EPI; High field; Long echo time; Rat brain; Snapshot

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; BRAIN CORTEX; CONTROLLED STUDY; ECHO PLANAR IMAGING; FEASIBILITY STUDY; GEOMETRY; GRADIENT RECALLED ECHO PLANAR IMAGING; IMAGE DISPLAY; IMAGE QUALITY; MALE; NEUROANATOMY; NEUROIMAGING; NONHUMAN; PRIORITY JOURNAL; RAT; SENSITIVITY AND SPECIFICITY;

EID: 48549103312     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2008.01.009     Document Type: Article
Times cited : (6)

References (26)
  • 3
    • 0033854285 scopus 로고    scopus 로고
    • Imaging blood flow in brain tumors using arterial spin labeling
    • Silva A.C., Kim S.G., and Garwood M. Imaging blood flow in brain tumors using arterial spin labeling. Magn Reson Med 44 2 (2000) 169-173
    • (2000) Magn Reson Med , vol.44 , Issue.2 , pp. 169-173
    • Silva, A.C.1    Kim, S.G.2    Garwood, M.3
  • 4
    • 0028854355 scopus 로고
    • Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling
    • Silva A.C., Zhang W., Williams D.S., and Koretsky A.P. Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling. Magn Reson Med 33 2 (1995) 209-214
    • (1995) Magn Reson Med , vol.33 , Issue.2 , pp. 209-214
    • Silva, A.C.1    Zhang, W.2    Williams, D.S.3    Koretsky, A.P.4
  • 7
    • 0036842462 scopus 로고    scopus 로고
    • Effect of deep pentobarbital anesthesia on neurotransmitter metabolism in vivo: on the correlation of total glucose consumption with glutamatergic action
    • Choi I.Y., Lei H., and Gruetter R. Effect of deep pentobarbital anesthesia on neurotransmitter metabolism in vivo: on the correlation of total glucose consumption with glutamatergic action. J Cereb Blood Flow Metab 22 11 (2002) 1343-1351
    • (2002) J Cereb Blood Flow Metab , vol.22 , Issue.11 , pp. 1343-1351
    • Choi, I.Y.1    Lei, H.2    Gruetter, R.3
  • 10
    • 0034056817 scopus 로고    scopus 로고
    • The effect of bulk susceptibility on murine snapshot imaging at 7.0 T: a comparison of snapshot imaging techniques
    • Grieve S.M., Blamire A.M., and Styles P. The effect of bulk susceptibility on murine snapshot imaging at 7.0 T: a comparison of snapshot imaging techniques. Magn Reson Med 43 5 (2000) 747-755
    • (2000) Magn Reson Med , vol.43 , Issue.5 , pp. 747-755
    • Grieve, S.M.1    Blamire, A.M.2    Styles, P.3
  • 11
    • 0033502655 scopus 로고    scopus 로고
    • Simultaneous blood oxygenation level-dependent and cerebral blood flow functional magnetic resonance imaging during forepaw stimulation in the rat
    • Silva A.C., Lee S.P., Yang G., Iadecola C., and Kim S.G. Simultaneous blood oxygenation level-dependent and cerebral blood flow functional magnetic resonance imaging during forepaw stimulation in the rat. J Cereb Blood Flow Metab 19 8 (1999) 871-879
    • (1999) J Cereb Blood Flow Metab , vol.19 , Issue.8 , pp. 871-879
    • Silva, A.C.1    Lee, S.P.2    Yang, G.3    Iadecola, C.4    Kim, S.G.5
  • 12
    • 32844465854 scopus 로고    scopus 로고
    • Interleaved snapshot echo planar imaging of mouse brain at 7.0 T
    • Guilfoyle D.N., and Hrabe J. Interleaved snapshot echo planar imaging of mouse brain at 7.0 T. NMR Biomed 19 1 (2006) 108-115
    • (2006) NMR Biomed , vol.19 , Issue.1 , pp. 108-115
    • Guilfoyle, D.N.1    Hrabe, J.2
  • 13
    • 0029999243 scopus 로고    scopus 로고
    • Magnetic resonance imaging (MRI) detection of the murine brain response to light: temporal differentiation and negative functional MRI changes
    • Huang W., Plyka I., Li H., Eisenstein E.M., Volkow N.D., and Springer Jr. C.S. Magnetic resonance imaging (MRI) detection of the murine brain response to light: temporal differentiation and negative functional MRI changes. Proc Natl Acad Sci U S A 93 12 (1996) 6037-6042
    • (1996) Proc Natl Acad Sci U S A , vol.93 , Issue.12 , pp. 6037-6042
    • Huang, W.1    Plyka, I.2    Li, H.3    Eisenstein, E.M.4    Volkow, N.D.5    Springer Jr., C.S.6
  • 14
    • 33644546721 scopus 로고    scopus 로고
    • Single-shot echo-planar functional magnetic resonance imaging of representations of the fore- and hindpaws in the somatosensory cortex of rats using an 11.7 T microimager
    • Chen Z., and Shen J. Single-shot echo-planar functional magnetic resonance imaging of representations of the fore- and hindpaws in the somatosensory cortex of rats using an 11.7 T microimager. J Neurosci Methods 151 2 (2006) 268-275
    • (2006) J Neurosci Methods , vol.151 , Issue.2 , pp. 268-275
    • Chen, Z.1    Shen, J.2
  • 15
    • 3543117315 scopus 로고    scopus 로고
    • Echo-planar BOLD fMRI of mice on a narrow-bore 9.4 T magnet
    • Nair G., and Duong T.Q. Echo-planar BOLD fMRI of mice on a narrow-bore 9.4 T magnet. Magn Reson Med 52 2 (2004) 430-434
    • (2004) Magn Reson Med , vol.52 , Issue.2 , pp. 430-434
    • Nair, G.1    Duong, T.Q.2
  • 16
    • 0342948677 scopus 로고    scopus 로고
    • Field mapping without reference scan using asymmetric echo-planar techniques
    • Gruetter R., and Tkac I. Field mapping without reference scan using asymmetric echo-planar techniques. Magn Reson Med 43 2 (2000) 319-323
    • (2000) Magn Reson Med , vol.43 , Issue.2 , pp. 319-323
    • Gruetter, R.1    Tkac, I.2
  • 18
    • 0032707824 scopus 로고    scopus 로고
    • Linear projection method for automatic slice shimming
    • Shen J., Rothman D.L., Hetherington H.P., and Pan J.W. Linear projection method for automatic slice shimming. Magn Reson Med 42 6 (1999) 1082-1088
    • (1999) Magn Reson Med , vol.42 , Issue.6 , pp. 1082-1088
    • Shen, J.1    Rothman, D.L.2    Hetherington, H.P.3    Pan, J.W.4
  • 19
    • 33750632039 scopus 로고    scopus 로고
    • Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition
    • Mlynarik V., Gambarota G., Frenkel H., and Gruetter R. Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition. Magn Reson Med (2006)
    • (2006) Magn Reson Med
    • Mlynarik, V.1    Gambarota, G.2    Frenkel, H.3    Gruetter, R.4
  • 20
    • 0032769195 scopus 로고    scopus 로고
    • Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
    • Posse S., Wiese S., Gembris D., Mathiak K., Kessler C., Grosse-Ruyken M.L., et al. Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging. Magn Reson Med 42 1 (1999) 87-97
    • (1999) Magn Reson Med , vol.42 , Issue.1 , pp. 87-97
    • Posse, S.1    Wiese, S.2    Gembris, D.3    Mathiak, K.4    Kessler, C.5    Grosse-Ruyken, M.L.6
  • 21
    • 0032012581 scopus 로고    scopus 로고
    • Localized eddy current compensation using quantitative field mapping
    • Terpstra M., Andersen P.M., and Gruetter R. Localized eddy current compensation using quantitative field mapping. J Magn Reson 131 1 (1998) 139-143
    • (1998) J Magn Reson , vol.131 , Issue.1 , pp. 139-143
    • Terpstra, M.1    Andersen, P.M.2    Gruetter, R.3
  • 22
    • 0026601923 scopus 로고
    • Image reconstruction for echo planar imaging with nonequidistant k-space sampling
    • Bruder H., Fischer H., Reinfelder H.E., and Schmitt F. Image reconstruction for echo planar imaging with nonequidistant k-space sampling. Magn Reson Med 23 2 (1992) 311-323
    • (1992) Magn Reson Med , vol.23 , Issue.2 , pp. 311-323
    • Bruder, H.1    Fischer, H.2    Reinfelder, H.E.3    Schmitt, F.4
  • 23
    • 0034789167 scopus 로고    scopus 로고
    • Physiological noise in oxygenation-sensitive magnetic resonance imaging
    • Kruger G., and Glover G.H. Physiological noise in oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 46 4 (2001) 631-637
    • (2001) Magn Reson Med , vol.46 , Issue.4 , pp. 631-637
    • Kruger, G.1    Glover, G.H.2
  • 24
    • 4644350363 scopus 로고    scopus 로고
    • Functional MRI of the rodent somatosensory pathway using multislice echo planar imaging
    • Keilholz S.D., Silva A.C., Raman M., Merkle H., and Koretsky A.P. Functional MRI of the rodent somatosensory pathway using multislice echo planar imaging. Magn Reson Med 52 1 (2004) 89-99
    • (2004) Magn Reson Med , vol.52 , Issue.1 , pp. 89-99
    • Keilholz, S.D.1    Silva, A.C.2    Raman, M.3    Merkle, H.4    Koretsky, A.P.5
  • 25
    • 8944223517 scopus 로고    scopus 로고
    • Artifact reduction in EPI with phase-encoded reference scan
    • Hu X., and Le T.H. Artifact reduction in EPI with phase-encoded reference scan. Magn Reson Med 36 1 (1996) 166-171
    • (1996) Magn Reson Med , vol.36 , Issue.1 , pp. 166-171
    • Hu, X.1    Le, T.H.2
  • 26
    • 2942748091 scopus 로고    scopus 로고
    • Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction
    • Chen N.K., and Wyrwicz A.M. Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction. Magn Reson Med 51 6 (2004) 1247-1253
    • (2004) Magn Reson Med , vol.51 , Issue.6 , pp. 1247-1253
    • Chen, N.K.1    Wyrwicz, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.