메뉴 건너뛰기




Volumn 43, Issue 2, 2000, Pages 319-323

Field mapping without reference scan using asymmetric echo-planar techniques

Author keywords

B(o) imaging; BOLD; EPI; Field mapping; Shimming; Spectroscopy

Indexed keywords

SPECTROSCOPY;

EID: 0342948677     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(200002)43:2<319::AID-MRM22>3.0.CO;2-1     Document Type: Article
Times cited : (494)

References (18)
  • 1
    • 0027200329 scopus 로고
    • Automatic, localized in vivo adjustment of all first- and second-order shim coils
    • Gruetter R. Automatic, localized in vivo adjustment of all first- and second-order shim coils. Magn Reson Med 1993;29:804-811.
    • (1993) Magn Reson Med , vol.29 , pp. 804-811
    • Gruetter, R.1
  • 2
    • 0030726451 scopus 로고    scopus 로고
    • Improvements on an in vivo automatic shimming method (FASTERMAP)
    • Shen J, Rycyna RE, Rothman DL. improvements on an in vivo automatic shimming method (FASTERMAP). Magn Reson Med 1997;30: 834-839.
    • (1997) Magn Reson Med , vol.30 , pp. 834-839
    • Shen, J.1    Rycyna, R.E.2    Rothman, D.L.3
  • 3
    • 0031847926 scopus 로고    scopus 로고
    • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain
    • Spielman DM, Adalsteinsson E, Lim KO. Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain. Magn Reson Med 1998;40:376-382.
    • (1998) Magn Reson Med , vol.40 , pp. 376-382
    • Spielman, D.M.1    Adalsteinsson, E.2    Lim, K.O.3
  • 5
    • 44049117202 scopus 로고
    • Fast, non-iterative shimming on spatially localized signals: In vivo analysis of the magnetic field along axes
    • Gruetter R, Boesch C. Fast, non-iterative shimming on spatially localized signals: in vivo analysis of the magnetic field along axes. J Magn Reson 1992;96:323-334.
    • (1992) J Magn Reson , vol.96 , pp. 323-334
    • Gruetter, R.1    Boesch, C.2
  • 6
    • 0029397236 scopus 로고
    • Automated shimming at 1.5 T using echo-planar image frequency maps
    • Reese TG, Davis TL, Weisskoff RM. Automated shimming at 1.5 T using echo-planar image frequency maps. J Magn Reson Imag 1995;5:739-745.
    • (1995) J Magn Reson Imag , vol.5 , pp. 739-745
    • Reese, T.G.1    Davis, T.L.2    Weisskoff, R.M.3
  • 7
    • 0029770663 scopus 로고    scopus 로고
    • In vivo rapid magnetic field measurement and shimming using single scan differential phase mapping
    • Kanayama S, Kuhara S, Satoh K. In vivo rapid magnetic field measurement and shimming using single scan differential phase mapping. Magn Reson Med 1996:36:637-642.
    • (1996) Magn Reson Med , vol.36 , pp. 637-642
    • Kanayama, S.1    Kuhara, S.2    Satoh, K.3
  • 8
    • 0029156119 scopus 로고
    • Interleaved asymmetric echo-planar imaging
    • Hennel F, Nedelec JF. Interleaved asymmetric echo-planar imaging. Magn Reson Med 1995;34:520-524.
    • (1995) Magn Reson Med , vol.34 , pp. 520-524
    • Hennel, F.1    Nedelec, J.F.2
  • 9
    • 0025256879 scopus 로고
    • Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation
    • Feinberg DA, Turner R, Jakab PD, von Kienlin M. Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation. Magn Reson Med 1990;13:162-169.
    • (1990) Magn Reson Med , vol.13 , pp. 162-169
    • Feinberg, D.A.1    Turner, R.2    Jakab, P.D.3    Von Kienlin, M.4
  • 11
    • 0025832805 scopus 로고
    • Rapid in vivo proton shimming
    • Schneider E, Glover G. Rapid in vivo proton shimming. Magn Reson Med 1991;18:335-347.
    • (1991) Magn Reson Med , vol.18 , pp. 335-347
    • Schneider, E.1    Glover, G.2
  • 12
    • 0025881282 scopus 로고
    • Rapid, fully automatic, arbitrary-volume in vivo shimming
    • Webb P, Macovski A. Rapid, fully automatic, arbitrary-volume in vivo shimming. Magn Reson Med 1991;20:113-122.
    • (1991) Magn Reson Med , vol.20 , pp. 113-122
    • Webb, P.1    Macovski, A.2
  • 13
    • 0028783994 scopus 로고
    • An in vivo automated shimming method taking into account shim current constraints
    • Wen H, Jaffer FA. An in vivo automated shimming method taking into account shim current constraints. Magn Reson Med 1995;34:898-904.
    • (1995) Magn Reson Med , vol.34 , pp. 898-904
    • Wen, H.1    Jaffer, F.A.2
  • 14
    • 0032012581 scopus 로고    scopus 로고
    • Localized eddy current compensation using quantitative field mapping
    • Terpstra M, Andersen P, Gruetter R. Localized eddy current compensation using quantitative field mapping. J Magn Reson 1998;131:139-143.
    • (1998) J Magn Reson , vol.131 , pp. 139-143
    • Terpstra, M.1    Andersen, P.2    Gruetter, R.3
  • 15
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • Hennig J, Nauerth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986;3:823-833.
    • (1986) Magn Reson Med , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 16
    • 44949273876 scopus 로고
    • Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets
    • Garwood M, Ke Y. Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets. J Magn Reson 1991;94:511-525.
    • (1991) J Magn Reson , vol.94 , pp. 511-525
    • Garwood, M.1    Ke, Y.2
  • 18
    • 0032588957 scopus 로고    scopus 로고
    • In vivo 1H NMR spectroscopy of rat brain at 1 ms echo time
    • Tkac I, Starcuk Z, Choi I-Y. Gruetter R. In vivo 1H NMR spectroscopy of rat brain at 1 ms echo time. Magn Reason Med 1999;41:649-656.
    • (1999) Magn Reason Med , vol.41 , pp. 649-656
    • Tkac, I.1    Starcuk, Z.2    Choi, I.-Y.3    Gruetter, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.