메뉴 건너뛰기




Volumn 51, Issue 6, 2004, Pages 1247-1253

Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction

Author keywords

Echo planar imaging; EPI; Nyquist ghost artifact

Indexed keywords

MAPPING;

EID: 2942748091     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20097     Document Type: Article
Times cited : (76)

References (17)
  • 1
    • 0032817609 scopus 로고    scopus 로고
    • The effect of residual Nyquist ghost in quantitative echo-planar diffusion imaging
    • Porter DA, Calamante F, Gadian DG, Connelly A. The effect of residual Nyquist ghost in quantitative echo-planar diffusion imaging. Magn Reson Med 1999;42:385-392.
    • (1999) Magn Reson Med , vol.42 , pp. 385-392
    • Porter, D.A.1    Calamante, F.2    Gadian, D.G.3    Connelly, A.4
  • 2
    • 8944223517 scopus 로고    scopus 로고
    • Artifact reduction in EPI with phase-encoded reference scan
    • Hu X, Le TH. Artifact reduction in EPI with phase-encoded reference scan. Magn Reson Med 1996;36:166-171.
    • (1996) Magn Reson Med , vol.36 , pp. 166-171
    • Hu, X.1    Le, T.H.2
  • 3
    • 0032186364 scopus 로고    scopus 로고
    • Image-based reduction of artifacts in multi-shot echo-planar imaging
    • Hennel F. Image-based reduction of artifacts in multi-shot echo-planar imaging. J Magn Reson 1998;134:206-213.
    • (1998) J Magn Reson , vol.134 , pp. 206-213
    • Hennel, F.1
  • 4
    • 0036165145 scopus 로고    scopus 로고
    • Elimination of Nyquist ghosting caused by read-out to phase-encode gradient cross-terms in EPI
    • Grieve SM, Blamire AM, Styles P. Elimination of Nyquist ghosting caused by read-out to phase-encode gradient cross-terms in EPI. Magn Reson Med 2002;47:337-343.
    • (2002) Magn Reson Med , vol.47 , pp. 337-343
    • Grieve, S.M.1    Blamire, A.M.2    Styles, P.3
  • 5
    • 0030802130 scopus 로고    scopus 로고
    • Ghost artifact reduction for echo planar imaging using image phase correction
    • Buonocore MH, Gao L. Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 1997;38:89-100.
    • (1997) Magn Reson Med , vol.38 , pp. 89-100
    • Buonocore, M.H.1    Gao, L.2
  • 7
    • 0026601923 scopus 로고
    • Image reconstruction for EPI with non-equidistant k-space sampling
    • Bruder H, Fisher H, Reinfelder HE Schmitt F. Image reconstruction for EPI with non-equidistant k-space sampling. Magn Reson Med 1992; 23:311-323.
    • (1992) Magn Reson Med , vol.23 , pp. 311-323
    • Bruder, H.1    Fisher, H.2    Reinfelder, H.E.3    Schmitt, F.4
  • 8
    • 0033061743 scopus 로고    scopus 로고
    • High spatial resolution EPI using an odd number of interleaves
    • Buonocore MH, Zhu DC. High spatial resolution EPI using an odd number of interleaves. Magn Reson Med 1999;41:1119-1205.
    • (1999) Magn Reson Med , vol.41 , pp. 1119-1205
    • Buonocore, M.H.1    Zhu, D.C.2
  • 9
    • 0035158067 scopus 로고    scopus 로고
    • Image-based ghost correction for interleaved EPI
    • Buonocore MH, Zhu DC. Image-based ghost correction for interleaved EPI. Magn Reson Med 2001;45:96-108.
    • (2001) Magn Reson Med , vol.45 , pp. 96-108
    • Buonocore, M.H.1    Zhu, D.C.2
  • 10
    • 0002112769 scopus 로고
    • Correcting gross distortion on echo planar images
    • Berlin
    • Weisskoff RM, Davis TL. Correcting gross distortion on echo planar images. In: SMRM 11th Annual Meeting, vol. 10, Berlin, 1992. p 4515.
    • (1992) SMRM 11th Annual Meeting , vol.10 , pp. 4515
    • Weisskoff, R.M.1    Davis, T.L.2
  • 11
    • 0029034190 scopus 로고
    • Correction for geometrical distortion in echo planar images from Bo field variations
    • Jezzard P, Balaban RS. Correction for geometrical distortion in echo planar images from Bo field variations. Magn Reson Med 1995;34:65-73.
    • (1995) Magn Reson Med , vol.34 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 12
    • 2942737698 scopus 로고    scopus 로고
    • Single-shot and segmented EPI ghost artifacts removal with two-dimensional phase correction
    • ISMRM, Denver
    • Chen N-K, Wyrwicz AM. Single-shot and segmented EPI ghost artifacts removal with two-dimensional phase correction. In, 8th Annual Meeting, ISMRM, Denver, 2000. p 1713.
    • (2000) 8th Annual Meeting , pp. 1713
    • Chen, N.-K.1    Wyrwicz, A.M.2
  • 13
    • 0035354209 scopus 로고    scopus 로고
    • Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan
    • Schmithorst VJ, Dardzinski BJ, Holland SK. Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan. IEEE Trans Med Imag 2001;20:535-539.
    • (2001) IEEE Trans Med Imag , vol.20 , pp. 535-539
    • Schmithorst, V.J.1    Dardzinski, B.J.2    Holland, S.K.3
  • 14
    • 0030912558 scopus 로고    scopus 로고
    • Reduction of geometric and intensity distortions in echo-planar imaging using a multireference scan
    • Wan X, Gullberg GT, Parker DL, Zeng GL. Reduction of geometric and intensity distortions in echo-planar imaging using a multireference scan. Magn Reson Med 1997;37:932-944.
    • (1997) Magn Reson Med , vol.37 , pp. 932-944
    • Wan, X.1    Gullberg, G.T.2    Parker, D.L.3    Zeng, G.L.4
  • 15
    • 0031910857 scopus 로고    scopus 로고
    • Correction of off-resonance related distortion in echo-planar imaging using EPI-based field maps
    • Reber PJ, Wong EC, Buxton KB, Frank LR. Correction of off-resonance related distortion in echo-planar imaging using EPI-based field maps. Magn Reson Med 1998;39:328-330.
    • (1998) Magn Reson Med , vol.39 , pp. 328-330
    • Reber, P.J.1    Wong, E.C.2    Buxton, K.B.3    Frank, L.R.4
  • 16
    • 0032994289 scopus 로고    scopus 로고
    • Correction for EPI distortions using multi-echo gradient-echo imaging
    • Chen N-K, Wyrwicz AM. Correction for EPI distortions using multi-echo gradient-echo imaging. Magn Reson Med 1999;41:1206-1213.
    • (1999) Magn Reson Med , vol.41 , pp. 1206-1213
    • Chen, N.-K.1    Wyrwicz, A.M.2
  • 17
    • 0035101324 scopus 로고    scopus 로고
    • Optimized distortion correction technique for echo planar imaging
    • Chen N-K, Wyrwicz AM. Optimized distortion correction technique for echo planar imaging. Magn Reson Med 2001;45:525-528.
    • (2001) Magn Reson Med , vol.45 , pp. 525-528
    • Chen, N.-K.1    Wyrwicz, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.