메뉴 건너뛰기




Volumn 14, Issue 2, 2007, Pages 138-143

Computational fluid dynamics within bifurcated abdominal aortic stent-grafts

Author keywords

Abdominal aortic; Hemodynamics; Sac pressure; Shear forces; Stent graft

Indexed keywords

ABDOMINAL AORTA; AORTA BIFURCATION; ARTERIAL PRESSURE; ARTERY DILATATION; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; ENDOLEAK; ENDOVASCULAR SURGERY; HEART CYCLE; PRIORITY JOURNAL; SPATIAL DISCRIMINATION; STENT;

EID: 34248645707     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/1545-1550(2007)14[138:CFDWBA]2.0.CO;2     Document Type: Article
Times cited : (82)

References (17)
  • 1
    • 0141478914 scopus 로고    scopus 로고
    • Endo-exuberance to endo-reality: Trends in the management of 431 AAA repairs between 1996 and 2002
    • Sternbergh WC, Nordness PJ, York JW, et al. Endo-exuberance to endo-reality: trends in the management of 431 AAA repairs between 1996 and 2002. J Endovasc Ther. 2003;10:418-423.
    • (2003) J Endovasc Ther , vol.10 , pp. 418-423
    • Sternbergh, W.C.1    Nordness, P.J.2    York, J.W.3
  • 2
    • 0035111634 scopus 로고    scopus 로고
    • Results of an aortic endograft trial: Impact of device failure beyond 12 months
    • Beebe HG, Cronenwett JL, Katzen BT, et al. Results of an aortic endograft trial: impact of device failure beyond 12 months. J Vasc Surg. 2001;33:S55-63.
    • (2001) J Vasc Surg , vol.33
    • Beebe, H.G.1    Cronenwett, J.L.2    Katzen, B.T.3
  • 3
    • 3543120606 scopus 로고    scopus 로고
    • An update on the important findings from the EUROSTAR EVAR registry
    • Harris PL, Buth J. An update on the important findings from the EUROSTAR EVAR registry. Vascular. 2004;12:33-38.
    • (2004) Vascular , vol.12 , pp. 33-38
    • Harris, P.L.1    Buth, J.2
  • 4
    • 0034862755 scopus 로고    scopus 로고
    • Analytical modeling and numerical simulation of forces in an endoluminal graft
    • Liffman K, Lawrence-Brown MM, Semmens JB, et al. Analytical modeling and numerical simulation of forces in an endoluminal graft. J Endovasc Ther. 2001;8:358-371.
    • (2001) J Endovasc Ther , vol.8 , pp. 358-371
    • Liffman, K.1    Lawrence-Brown, M.M.2    Semmens, J.B.3
  • 5
    • 2542490236 scopus 로고    scopus 로고
    • A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)
    • Morris L, Delassus P, Walsh M, et al. A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA). J Biomech. 2004;37:1087-1095.
    • (2004) J Biomech , vol.37 , pp. 1087-1095
    • Morris, L.1    Delassus, P.2    Walsh, M.3
  • 6
    • 0037400885 scopus 로고    scopus 로고
    • Flow changes in the aorta associated with the deployment of a AAA stent graft
    • Walsh PW, Chin Quee SC, Moore JE. Flow changes in the aorta associated with the deployment of a AAA stent graft. Med Eng Phys. 2003;25:299-307.
    • (2003) Med Eng Phys , vol.25 , pp. 299-307
    • Walsh, P.W.1    Chin Quee, S.C.2    Moore, J.E.3
  • 7
    • 30844462131 scopus 로고    scopus 로고
    • Effects of flat, parabolic and realistic steady flow inlet profiles on idealised and realistic stent graft fits through abdominal aortic aneurysms (AAA)
    • Morris L, Delassus P, Grace P, et al. Effects of flat, parabolic and realistic steady flow inlet profiles on idealised and realistic stent graft fits through abdominal aortic aneurysms (AAA). Med Eng Phys. 2006;28:19-26.
    • (2006) Med Eng Phys , vol.28 , pp. 19-26
    • Morris, L.1    Delassus, P.2    Grace, P.3
  • 8
    • 33749063625 scopus 로고    scopus 로고
    • Computational analysis of type II endoleaks in a stented abdominal aortic aneurysm model
    • Li Z, Kleinstreuer C. Computational analysis of type II endoleaks in a stented abdominal aortic aneurysm model. J Biomech. 2006;39:2573-2582.
    • (2006) J Biomech , vol.39 , pp. 2573-2582
    • Li, Z.1    Kleinstreuer, C.2
  • 9
    • 0037003381 scopus 로고    scopus 로고
    • Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair
    • Mohan IV, Harris PL, van Marrewijk CJ, et al. Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair. J Endovasc Ther. 2002;9:748-755.
    • (2002) J Endovasc Ther , vol.9 , pp. 748-755
    • Mohan, I.V.1    Harris, P.L.2    van Marrewijk, C.J.3
  • 10
    • 2942735045 scopus 로고    scopus 로고
    • A simulated dye method for flow visualization with a computational model for blood flow
    • Kim T, Dwyer HA, Cheer AY. A simulated dye method for flow visualization with a computational model for blood flow. J Biomech. 2004;37:1125-1136.
    • (2004) J Biomech , vol.37 , pp. 1125-1136
    • Kim, T.1    Dwyer, H.A.2    Cheer, A.Y.3
  • 11
    • 0036667709 scopus 로고    scopus 로고
    • Unsteady and three-dimensional simulation of blood flow in the human aortic arch
    • Shahcheraghi N, Dwyer HA, Cheer AY, et al. Unsteady and three-dimensional simulation of blood flow in the human aortic arch. J Biomech Eng. 2002;124:378-387.
    • (2002) J Biomech Eng , vol.124 , pp. 378-387
    • Shahcheraghi, N.1    Dwyer, H.A.2    Cheer, A.Y.3
  • 12
    • 34248654965 scopus 로고    scopus 로고
    • Pulsatile movement of the Zenith Aortic Stent-Graft
    • Presented at the, Munich, Germany; July
    • Howell B, Hughes-Lopes MA, Saloner D, et al. Pulsatile movement of the Zenith Aortic Stent-Graft. Presented at the World Congress of Biomechanics. Munich, Germany; July 2006.
    • (2006) World Congress of Biomechanics
    • Howell, B.1    Hughes-Lopes, M.A.2    Saloner, D.3
  • 13
    • 3242716166 scopus 로고    scopus 로고
    • Intraaneurysm sac pressure measurements after endovascular aneurysm repair: Differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks
    • Dias NV, Ivancev K, Malina M, et al. Intraaneurysm sac pressure measurements after endovascular aneurysm repair: differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. J Vasc Surg. 2004;39:1229-1235.
    • (2004) J Vasc Surg , vol.39 , pp. 1229-1235
    • Dias, N.V.1    Ivancev, K.2    Malina, M.3
  • 14
    • 0031647079 scopus 로고    scopus 로고
    • Endovascular AAA exclusion: Will stents with hooks and barbs prevent stent-graft migration?
    • Malina M, Lindblad B, Ivancev K, et al. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration? J Endovasc Surg. 1998;5:310-317.
    • (1998) J Endovasc Surg , vol.5 , pp. 310-317
    • Malina, M.1    Lindblad, B.2    Ivancev, K.3
  • 15
    • 0346964283 scopus 로고    scopus 로고
    • Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: Results from the Zenith Multicenter Trial
    • Sternbergh WC, Money SR, Greenberg RK, et al. Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith Multicenter Trial. J Vasc Surg. 2004;39:20-26.
    • (2004) J Vasc Surg , vol.39 , pp. 20-26
    • Sternbergh, W.C.1    Money, S.R.2    Greenberg, R.K.3
  • 16
    • 0344897143 scopus 로고    scopus 로고
    • Factors affecting the displacement force exerted on a stent graft after AAA repair - an in vitro study
    • Volodos SM, Sayers RD, Gostelow JP, et al. Factors affecting the displacement force exerted on a stent graft after AAA repair - an in vitro study. Eur J Vasc Endovasc Surg. 2003;26:596-601.
    • (2003) Eur J Vasc Endovasc Surg , vol.26 , pp. 596-601
    • Volodos, S.M.1    Sayers, R.D.2    Gostelow, J.P.3
  • 17
    • 3242691741 scopus 로고    scopus 로고
    • Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device
    • Cho JS, Dillavou ED, Rhee RY, et al. Late abdominal aortic aneurysm enlargement after endovascular repair with the Excluder device. J Vasc Surg. 2004;39:1236-1242.
    • (2004) J Vasc Surg , vol.39 , pp. 1236-1242
    • Cho, J.S.1    Dillavou, E.D.2    Rhee, R.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.