메뉴 건너뛰기




Volumn 9, Issue 6, 2002, Pages 748-755

Factors and forces influencing stent-graft migration after endovascular aortic aneurysm repair

Author keywords

Abdominal aortic aneurysm; Aneurysm morphology; Hypertension; Iliac angulation; Migration; Stent graft design; Theoretical model

Indexed keywords

ANEURYSM SURGERY; AORTA ANEURYSM; AORTA GRAFT; ARTICLE; BLOOD FLOW; CALCULATION; CLINICAL FEATURE; DEMOGRAPHY; DEVICE; DISEASE ASSOCIATION; ENDOPROSTHESIS LOOSENING; ENDOVASCULAR SURGERY; FORCE; FOREIGN BODY; HUMAN; HYPERTENSION; ILIAC BONE; MAJOR CLINICAL STUDY; MATHEMATICAL MODEL; MORPHOLOGY; MOTION; MULTIVARIATE ANALYSIS; OUTCOMES RESEARCH; PRIORITY JOURNAL; PROSTHESIS FIXATION; PULSE PRESSURE; REGRESSION ANALYSIS; RISK ASSESSMENT; RISK FACTOR; SMOKING AND SMOKING RELATED PHENOMENA; STENT; VALIDATION PROCESS;

EID: 0037003381     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/1545-1550(2002)009<0748:FAFISG>2.0.CO;2     Document Type: Article
Times cited : (113)

References (13)
  • 1
    • 0033782683 scopus 로고    scopus 로고
    • Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience
    • Harris PL, Vallabhaneni SR, Desgranges P, et al. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. J Vasc Surg. 2000;32:739-749.
    • (2000) J Vasc Surg , vol.32 , pp. 739-749
    • Harris, P.L.1    Vallabhaneni, S.R.2    Desgranges, P.3
  • 2
    • 0032976367 scopus 로고    scopus 로고
    • Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms
    • Resch T, Ivancev K, Brunkwall J, et al. Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol. 1999;10:257-264.
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 257-264
    • Resch, T.1    Ivancev, K.2    Brunkwall, J.3
  • 3
    • 0034093671 scopus 로고    scopus 로고
    • Endovascular healing is inadequate for fixation of Dacron stent grafts in human aortoiliac vessels
    • Malina M, Brunkwall J, Ivancev K, et al. Endovascular healing is inadequate for fixation of Dacron stent grafts in human aortoiliac vessels. Eur J Vasc Endovasc Surg. 2000;19:5-11.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 5-11
    • Malina, M.1    Brunkwall, J.2    Ivancev, K.3
  • 4
    • 0031019823 scopus 로고    scopus 로고
    • Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms
    • Blum U, Voshage G, Lammer J, et al. Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms. N Engl J Med. 1997;336:13-20.
    • (1997) N Engl J Med , vol.336 , pp. 13-20
    • Blum, U.1    Voshage, G.2    Lammer, J.3
  • 5
    • 0031963665 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm treatment: Preliminary results with the Talent stent-graft system
    • Uflacker R, Robison JG, Brothers T, et al. Abdominal aortic aneurysm treatment: preliminary results with the Talent stent-graft system. J Vasc Interv Radiol. 1998;9:51-60.
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 51-60
    • Uflacker, R.1    Robison, J.G.2    Brothers, T.3
  • 6
    • 0033845597 scopus 로고    scopus 로고
    • The impact of stent design on proximal stent-graft fixation in the abdominal aorta: An experimental study
    • Resch T, Malina M, Lindblad B, et al. The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study. Eur J Vasc Endovasc Surg. 2000;20:190-195.
    • (2000) Eur J Vasc Endovasc Surg , vol.20 , pp. 190-195
    • Resch, T.1    Malina, M.2    Lindblad, B.3
  • 7
    • 0031050675 scopus 로고    scopus 로고
    • The need for clinical trials of endovascular abdominal aortic aneurysm stent-graft repair: The EUROSTAR project
    • Harris PL, Buth J, Mialhe C, et al. The need for clinical trials of endovascular abdominal aortic aneurysm stent-graft repair: the EUROSTAR project. Eur J Vasc Endovasc Surg. 1997;4:72-79.
    • (1997) Eur J Vasc Endovasc Surg , vol.4 , pp. 72-79
    • Harris, P.L.1    Buth, J.2    Mialhe, C.3
  • 8
    • 0004180181 scopus 로고    scopus 로고
    • Revised by Ward-Smith J. London, UK: Stanley Thornes Publ
    • Massey B. Mechanics of fluids. 7th ed. Revised by Ward-Smith J. London, UK: Stanley Thornes Publ; 2000.
    • (2000) Mechanics of Fluids 7th Ed.
    • Massey, B.1
  • 9
    • 0031647079 scopus 로고    scopus 로고
    • Endovascular AAA exclusion: Will stents with hooks and barbs prevent stent-graft migration?
    • Malina M, Lindblad B, Ivancev K, et al. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration? J Endovasc Surg. 1998;5:310-317.
    • (1998) J Endovasc Surg , vol.5 , pp. 310-317
    • Malina, M.1    Lindblad, B.2    Ivancev, K.3
  • 10
    • 0030882610 scopus 로고    scopus 로고
    • Abdominal aortic aneurysms: Experience with the Ivancev-Malmo endovascular system for aortomonoiliac stent-grafts
    • Ivancev K, Malina M, Lindblad B, et al. Abdominal aortic aneurysms: experience with the Ivancev-Malmo endovascular system for aortomonoiliac stent-grafts. J Endovasc Surg. 1997;4:242-251.
    • (1997) J Endovasc Surg , vol.4 , pp. 242-251
    • Ivancev, K.1    Malina, M.2    Lindblad, B.3
  • 11
    • 0031689178 scopus 로고    scopus 로고
    • Continued expansion of aortic necks after endovascular repair of abdominal aortic aneurysms
    • Matsumura JS, Chaikof EL. Continued expansion of aortic necks after endovascular repair of abdominal aortic aneurysms. J Vasc Surg. 1998;28:422-431.
    • (1998) J Vasc Surg , vol.28 , pp. 422-431
    • Matsumura, J.S.1    Chaikof, E.L.2
  • 12
    • 0033913379 scopus 로고    scopus 로고
    • Changes of the infrarenal aortic segment after conventional abdominal aortic aneurysm repair
    • Liapis C, Kakisis J, Kaperonis E, et al. Changes of the infrarenal aortic segment after conventional abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2000;19:643-647.
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 643-647
    • Liapis, C.1    Kakisis, J.2    Kaperonis, E.3
  • 13
    • 0034862755 scopus 로고    scopus 로고
    • Analytical modeling and numerical simulation of forces in an endoluminal graft
    • Liffman K, Lawrence-Brown MM, Semmens JB, et al. Analytical modeling and numerical simulation of forces in an endoluminal graft. J Endovasc Ther. 2001;8:358-371.
    • (2001) J Endovasc Ther , vol.8 , pp. 358-371
    • Liffman, K.1    Lawrence-Brown, M.M.2    Semmens, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.