Volumn 48, Issue 4, 2008, Pages 234-252

Calibration and measurement issues for therapeutic ultrasound

Author keywords

Calibration; Focused ultrasound; HIFU; HITU; Measurement; Physiotherapy; Ultrasound

Indexed keywords

ACOUSTIC FIELDS; ACOUSTIC WAVES; CALIBRATION; PHYSICAL THERAPY; SONOCHEMISTRY; STANDARDS; SURGERY; ULTRASONIC MEASUREMENT; ULTRASONIC TESTING; ULTRASONIC TRANSMISSION;

EID: 48149114826     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2007.10.010     Document Type: Article
Times cited : (71)

References (137)
  • 1
    • 84960995896 scopus 로고
    • Effect of u/s on tendon extensibility
    • Gersten J.W. Effect of u/s on tendon extensibility. Am. J. Phys. Med. 34 (1955) 362-369
    • (1955) Am. J. Phys. Med. , vol.34 , pp. 362-369
    • Gersten, J.W.1
  • 3
    • 0019208888 scopus 로고
    • Extracorporeally induced destruction of kidney stones by shock waves
    • Chaussy C., Brendel W., and Schmiedt E. Extracorporeally induced destruction of kidney stones by shock waves. Lancet 2 (1980) 1265-1268
    • (1980) Lancet , vol.2 , pp. 1265-1268
    • Chaussy, C.1    Brendel, W.2    Schmiedt, E.3
  • 4
    • 33751333444 scopus 로고    scopus 로고
    • Therapeutic applications of ultrasound
    • ter Haar G. Therapeutic applications of ultrasound. Prog. Biophys. Molec. Biol. 93 (2007) 111-129
    • (2007) Prog. Biophys. Molec. Biol. , vol.93 , pp. 111-129
    • ter Haar, G.1
  • 5
    • 48149108236 scopus 로고    scopus 로고
    • International Electrotechnical Commission, Testing and calibration of ultrasonic therapeutic equipment, IEC 150, 1963.
    • International Electrotechnical Commission, Testing and calibration of ultrasonic therapeutic equipment, IEC 150, 1963.
  • 6
    • 48149090724 scopus 로고    scopus 로고
    • C.R. Hill, G. ter Haar, Ultrasound in non-ionizing radiation protection, in: M.J. Suess (Ed.), WHO Regional Publications, European Series No. 10, WHO, Copenhagen, 1981.
    • C.R. Hill, G. ter Haar, Ultrasound in non-ionizing radiation protection, in: M.J. Suess (Ed.), WHO Regional Publications, European Series No. 10, WHO, Copenhagen, 1981.
  • 7
    • 48149099417 scopus 로고    scopus 로고
    • US Food and Drug Administration (FDA), Radiation safety performance standard. Ultrasound therapy products, Title 21, Part 1050.10, Rules and Regulations, February 1979.
    • US Food and Drug Administration (FDA), Radiation safety performance standard. Ultrasound therapy products, Title 21, Part 1050.10, Rules and Regulations, February 1979.
  • 8
    • 48149110995 scopus 로고    scopus 로고
    • IEC 61689:1996, Ultrasonics - physiotherapy systems - Performance requirements and methods of measurement in the frequency range 0.5 to 5 MHz, International Electrotechnical Commission, Geneva, Switzerland.
    • IEC 61689:1996, Ultrasonics - physiotherapy systems - Performance requirements and methods of measurement in the frequency range 0.5 to 5 MHz, International Electrotechnical Commission, Geneva, Switzerland.
  • 9
    • 48149101630 scopus 로고    scopus 로고
    • International Electrotechnical Commission, Medical electrical equipment: particular requirements for the safety of ultrasonic physiotherapy equipment, IEC 60601-2-5, 2001.
    • International Electrotechnical Commission, Medical electrical equipment: particular requirements for the safety of ultrasonic physiotherapy equipment, IEC 60601-2-5, 2001.
  • 10
    • 33947118735 scopus 로고    scopus 로고
    • High intensity focused ultrasound: physical principles and devices
    • ter Haar G., and Coussios C.C. High intensity focused ultrasound: physical principles and devices. Int. J. Hyperthermia 23 2 (2007) 89-104
    • (2007) Int. J. Hyperthermia , vol.23 , Issue.2 , pp. 89-104
    • ter Haar, G.1    Coussios, C.C.2
  • 11
    • 33845416619 scopus 로고
    • A new method for the generation and use of focused ultrasound in experimental biology
    • Lynn G.R., Zwemer R.L., Chick A.J., and Miller A.F. A new method for the generation and use of focused ultrasound in experimental biology. J. Gen. Physiol. 26 (1942) 179-193
    • (1942) J. Gen. Physiol. , vol.26 , pp. 179-193
    • Lynn, G.R.1    Zwemer, R.L.2    Chick, A.J.3    Miller, A.F.4
  • 12
    • 0000214617 scopus 로고
    • Changes produced in the central nervous system by ultrasound
    • Wall P.D., Fry W.J., Stephens R., Tucker D., and Lettvin J.Y. Changes produced in the central nervous system by ultrasound. Science 114 (1951) 686-687
    • (1951) Science , vol.114 , pp. 686-687
    • Wall, P.D.1    Fry, W.J.2    Stephens, R.3    Tucker, D.4    Lettvin, J.Y.5
  • 13
    • 0000872778 scopus 로고
    • Production of focal destructive lesions in the central nervous system with ultrasound
    • Fry W.J., Mosberg W.H., Barnard J.W., and Fry F.J. Production of focal destructive lesions in the central nervous system with ultrasound. J. Neurosurg. 11 (1954) 471-478
    • (1954) J. Neurosurg. , vol.11 , pp. 471-478
    • Fry, W.J.1    Mosberg, W.H.2    Barnard, J.W.3    Fry, F.J.4
  • 14
    • 48149088297 scopus 로고    scopus 로고
    • A. Shaw, G. ter Haar, Requirements for measurement standards in high intensity focused ultrasound (HIFU) fields, NPL Report DQL-AC 015, 2006 (ISSN 1744-0599; available from: ).
    • A. Shaw, G. ter Haar, Requirements for measurement standards in high intensity focused ultrasound (HIFU) fields, NPL Report DQL-AC 015, 2006 (ISSN 1744-0599; available from: ).
  • 16
    • 0018356717 scopus 로고
    • Using surveys of ultrasound therapy devices to draft performance standards
    • Repacholi M.H., and Benwell D.A. Using surveys of ultrasound therapy devices to draft performance standards. Health Phys. 36 6 (1979) 679-686
    • (1979) Health Phys. , vol.36 , Issue.6 , pp. 679-686
    • Repacholi, M.H.1    Benwell, D.A.2
  • 17
    • 0020458511 scopus 로고
    • Ultrasound therapy units in Manitoba and Northwestern Ontario: performance evaluation
    • Snow C.J. Ultrasound therapy units in Manitoba and Northwestern Ontario: performance evaluation. Physiother. Can 34 4 (1982) 185-189
    • (1982) Physiother. Can , vol.34 , Issue.4 , pp. 185-189
    • Snow, C.J.1
  • 19
    • 0028339558 scopus 로고
    • The performance of ultrasound therapy machines in Lothian region, 1992
    • Pye S.D., and Milford C. The performance of ultrasound therapy machines in Lothian region, 1992. Ultrasound Med. Biol. 20 4 (1994) 347-359
    • (1994) Ultrasound Med. Biol. , vol.20 , Issue.4 , pp. 347-359
    • Pye, S.D.1    Milford, C.2
  • 21
    • 0018830124 scopus 로고
    • Considerations in ultrasound therapy and equipment performance
    • Stewart H.F., Abzug J.L., and Harris G.R. Considerations in ultrasound therapy and equipment performance. Phys. Therapy 60 4 (1980) 424-428
    • (1980) Phys. Therapy , vol.60 , Issue.4 , pp. 424-428
    • Stewart, H.F.1    Abzug, J.L.2    Harris, G.R.3
  • 22
    • 0030049830 scopus 로고    scopus 로고
    • Ultrasound therapy equipment - does it perform?
    • Pye S.D. Ultrasound therapy equipment - does it perform?. Physiotherapy 82 1 (1996) 39-44
    • (1996) Physiotherapy , vol.82 , Issue.1 , pp. 39-44
    • Pye, S.D.1
  • 23
    • 48149097724 scopus 로고    scopus 로고
    • Safety Action Notice SAN(SC) 97/12, issued March 1997, Scottish Healthcare Supplies, Edinburgh.
    • Safety Action Notice SAN(SC) 97/12, issued March 1997, Scottish Healthcare Supplies, Edinburgh.
  • 24
    • 48149083992 scopus 로고    scopus 로고
    • Safety Action Notice SAN(SC) 06/44, issued September 2006, Scottish Healthcare Supplies, Edinburgh.
    • Safety Action Notice SAN(SC) 06/44, issued September 2006, Scottish Healthcare Supplies, Edinburgh.
  • 25
    • 48149109614 scopus 로고    scopus 로고
    • Medical Device and Equipment Alerts (MDEA) (NI)2006-59, Department of Health, Social Services and Public Safety, Belfast.
    • Medical Device and Equipment Alerts (MDEA) (NI)2006-59, Department of Health, Social Services and Public Safety, Belfast.
  • 26
    • 85176658743 scopus 로고    scopus 로고
    • Chartered Society of Physiotherapy, Guidelines for the safe use of ultrasound physiotherapy equipment, Physiotherapy 76 (11) (1990) 683-684.
    • Chartered Society of Physiotherapy, Guidelines for the safe use of ultrasound physiotherapy equipment, Physiotherapy 76 (11) (1990) 683-684.
  • 27
    • 48149098047 scopus 로고    scopus 로고
    • Institute of Physics in Engineering and Medicine (IPEM), Report No. 84(2001), Guidelines for the testing and calibration of physiotherapy ultrasound equipment.
    • Institute of Physics in Engineering and Medicine (IPEM), Report No. 84(2001), Guidelines for the testing and calibration of physiotherapy ultrasound equipment.
  • 28
    • 48149112308 scopus 로고    scopus 로고
    • International Electrotechnical Commission, Ultrasonics - Output Test - Guide for the maintenance of ultrasound physiotherapy systems, IEC/TS 62462, 2007.
    • International Electrotechnical Commission, Ultrasonics - Output Test - Guide for the maintenance of ultrasound physiotherapy systems, IEC/TS 62462, 2007.
  • 30
    • 0343914249 scopus 로고
    • Balance technique for the measurement of very low ultrasonic power outputs
    • Kossoff G. Balance technique for the measurement of very low ultrasonic power outputs. JASA 38 5 (1965) 880-881
    • (1965) JASA , vol.38 , Issue.5 , pp. 880-881
    • Kossoff, G.1
  • 31
    • 0023294766 scopus 로고
    • Radiation force calculations
    • Beissner K. Radiation force calculations. Acustica 62 (1987) 255-263
    • (1987) Acustica , vol.62 , pp. 255-263
    • Beissner, K.1
  • 32
    • 0002976643 scopus 로고
    • Ultrasonic measurement techniques
    • Repacholi M.H., and Benwell D.A. (Eds), Humana Press, Clifton
    • Stewart H.F. Ultrasonic measurement techniques. In: Repacholi M.H., and Benwell D.A. (Eds). Essentials of Medical Ultrasound (1982), Humana Press, Clifton 77-116
    • (1982) Essentials of Medical Ultrasound , pp. 77-116
    • Stewart, H.F.1
  • 33
    • 0001814584 scopus 로고
    • Ultrasonic power balances
    • Preston R.C. (Ed), Springer Verlag, New York
    • Davidson F. Ultrasonic power balances. In: Preston R.C. (Ed). Output Measurements for Medical Ultrasound (1991), Springer Verlag, New York 75-89
    • (1991) Output Measurements for Medical Ultrasound , pp. 75-89
    • Davidson, F.1
  • 34
    • 48149100771 scopus 로고    scopus 로고
    • IEC61161:2006, Ed.2. Ultrasonics - Power measurement - Radiation force balances and performance requirements, International Electrotechnical Commission, Geneva, 2006.
    • IEC61161:2006, Ed.2. Ultrasonics - Power measurement - Radiation force balances and performance requirements, International Electrotechnical Commission, Geneva, 2006.
  • 35
    • 0033320223 scopus 로고    scopus 로고
    • Primary measurement of ultrasonic power and dissemination of ultrasonic power reference values by means of standard transducers
    • Beissner K. Primary measurement of ultrasonic power and dissemination of ultrasonic power reference values by means of standard transducers. Metrologia 36 (1999) 313-320
    • (1999) Metrologia , vol.36 , pp. 313-320
    • Beissner, K.1
  • 36
    • 48149087958 scopus 로고    scopus 로고
    • R.T. Hekkenberg, K. Beissner, B. Zeqiri, Therapy-level ultrasonic power measurement, Final Technical report SMT4-CT96-2139, European Commission, BCR Information, Report EUR18828, 2000.
    • R.T. Hekkenberg, K. Beissner, B. Zeqiri, Therapy-level ultrasonic power measurement, Final Technical report SMT4-CT96-2139, European Commission, BCR Information, Report EUR18828, 2000.
  • 38
    • 0002516147 scopus 로고
    • Acoustic streaming due to attenuated plane waves
    • Nyborg W.L. Acoustic streaming due to attenuated plane waves. J. Acoust. Soc. Am. 25 (1953) 68-75
    • (1953) J. Acoust. Soc. Am. , vol.25 , pp. 68-75
    • Nyborg, W.L.1
  • 39
    • 0242365331 scopus 로고    scopus 로고
    • Measurement of ultrasonic power using an acoustically absorbing well
    • Sutton Y.C., Shaw A., and Zeqiri B. Measurement of ultrasonic power using an acoustically absorbing well. Ultrasound Med. Biol. 29 10 (2003) 1507-1513
    • (2003) Ultrasound Med. Biol. , vol.29 , Issue.10 , pp. 1507-1513
    • Sutton, Y.C.1    Shaw, A.2    Zeqiri, B.3
  • 40
    • 0031042962 scopus 로고    scopus 로고
    • Sonic effervescence: a tutorial on acoustic cavitation
    • Apfel R.E. Sonic effervescence: a tutorial on acoustic cavitation. JASA 101 3 (1997) 1227-1237
    • (1997) JASA , vol.101 , Issue.3 , pp. 1227-1237
    • Apfel, R.E.1
  • 41
    • 33747829480 scopus 로고    scopus 로고
    • A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power
    • Hodnett M., and Zeqiri B. A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power. J. Phys. Conf. Ser. 1 (2004) 112-117.
    • (2004) J. Phys. Conf. Ser. , vol.1 , pp. 112-117
    • Hodnett, M.1    Zeqiri, B.2
  • 42
    • 48149089639 scopus 로고    scopus 로고
    • Precision Acoustics Continuous Wave check source, (11.07.07).
    • Precision Acoustics Continuous Wave check source, (11.07.07).
  • 45
    • 0014538580 scopus 로고
    • A radiation power calorimeter and a radiation force meter for small ultrasonic beams
    • Van Den Ende H. A radiation power calorimeter and a radiation force meter for small ultrasonic beams. Med. Biol. Eng. Comput. 7 4 (1969) 411-417
    • (1969) Med. Biol. Eng. Comput. , vol.7 , Issue.4 , pp. 411-417
    • Van Den Ende, H.1
  • 46
    • 47549100309 scopus 로고
    • An ultrasonic radiation calorimeter
    • Herman B., and Stewart H.F. An ultrasonic radiation calorimeter. JASA 53 1 (1973) 341
    • (1973) JASA , vol.53 , Issue.1 , pp. 341
    • Herman, B.1    Stewart, H.F.2
  • 47
    • 0028743038 scopus 로고
    • A calorimeter for ultrasound total power measurements
    • Delchar T.A., and Melvin R.J. A calorimeter for ultrasound total power measurements. Meas. Sci. Technol. 5 (1994) 1533-1537
    • (1994) Meas. Sci. Technol. , vol.5 , pp. 1533-1537
    • Delchar, T.A.1    Melvin, R.J.2
  • 48
    • 48149089638 scopus 로고    scopus 로고
    • G.R. Torr, A comparison of measurements of the powers of continuous and pulsed ultrasonic beams by calorimetric and radiation force methods, PhD thesis, University of Aberdeen, Scotland, 1981.
    • G.R. Torr, A comparison of measurements of the powers of continuous and pulsed ultrasonic beams by calorimetric and radiation force methods, PhD thesis, University of Aberdeen, Scotland, 1981.
  • 49
    • 0028212543 scopus 로고
    • Development of standard measurements methods for essential properties of ultrasound therapy equipment
    • Hekkenberg R.T., Reibold R., and Zeqiri B. Development of standard measurements methods for essential properties of ultrasound therapy equipment. Ultrasound Med. Biol. 20 (1994) 83-98
    • (1994) Ultrasound Med. Biol. , vol.20 , pp. 83-98
    • Hekkenberg, R.T.1    Reibold, R.2    Zeqiri, B.3
  • 50
    • 48149091936 scopus 로고    scopus 로고
    • R.T. Hekkenberg, Improvement of the standard for ultrasonic physiotherapy devices: survey of effective radiating areas, TNO Prevention and Health Report PG/TG/2004.253, Leiden, The Netherlands, 2004, ISBN 90-5412-091-6.
    • R.T. Hekkenberg, Improvement of the standard for ultrasonic physiotherapy devices: survey of effective radiating areas, TNO Prevention and Health Report PG/TG/2004.253, Leiden, The Netherlands, 2004, ISBN 90-5412-091-6.
  • 51
    • 48149085110 scopus 로고    scopus 로고
    • R.T. Hekkenberg, BCR report: Development of standard measurement methods for essential properties of ultrasound therapy equipment, Centre for Medical Technology TNO, Report CMT/92.031, Leiden, The Netherlands, 1992.
    • R.T. Hekkenberg, BCR report: Development of standard measurement methods for essential properties of ultrasound therapy equipment, Centre for Medical Technology TNO, Report CMT/92.031, Leiden, The Netherlands, 1992.
  • 52
    • 0017875713 scopus 로고
    • Performance of ultrasound therapy instruments
    • Allen K.G.R., and Battye C.K. Performance of ultrasound therapy instruments. Physiotherapy 64 (1978) 174-179
    • (1978) Physiotherapy , vol.64 , pp. 174-179
    • Allen, K.G.R.1    Battye, C.K.2
  • 53
    • 0034117818 scopus 로고    scopus 로고
    • A new anechoic material for medical ultrasonic applications
    • Zeqiri B., and Bickley C.J. A new anechoic material for medical ultrasonic applications. Ultrasound Med. Biol. 26 3 (2000) 481
    • (2000) Ultrasound Med. Biol. , vol.26 , Issue.3 , pp. 481
    • Zeqiri, B.1    Bickley, C.J.2
  • 54
    • 0032101325 scopus 로고    scopus 로고
    • A new method for measuring the effective radiating area of physiotherapy treatment heads
    • Zeqiri B., and Hodnett M. A new method for measuring the effective radiating area of physiotherapy treatment heads. Ultrasound Med. Biol. 24 (1998) 761-770
    • (1998) Ultrasound Med. Biol. , vol.24 , pp. 761-770
    • Zeqiri, B.1    Hodnett, M.2
  • 55
    • 48149087581 scopus 로고    scopus 로고
    • Medical Device Directive, Directive 93/42/EEC, Council of the European Communities, 1993.
    • Medical Device Directive, Directive 93/42/EEC, Council of the European Communities, 1993.
  • 56
    • 48149084789 scopus 로고    scopus 로고
    • IEC60601-1:2005, Ed. 3. Medical electrical equipment - Part 1: General requirements for basic safety and essential performance, International Electrotechnical Commission, Geneva, 2005.
    • IEC60601-1:2005, Ed. 3. Medical electrical equipment - Part 1: General requirements for basic safety and essential performance, International Electrotechnical Commission, Geneva, 2005.
  • 57
    • 48149101792 scopus 로고    scopus 로고
    • FDA, Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers, Food and Drug Administration, Rockville, MD 20850, USA, 1997.
    • FDA, Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers, Food and Drug Administration, Rockville, MD 20850, USA, 1997.
  • 58
    • 48149098199 scopus 로고    scopus 로고
    • IEC61846:1998, Ultrasonics - Pressure pulse lithotripters - Characteristics of fields, International Electrotechnical Commission, Geneva, 1998.
    • IEC61846:1998, Ultrasonics - Pressure pulse lithotripters - Characteristics of fields, International Electrotechnical Commission, Geneva, 1998.
  • 59
    • 33845419506 scopus 로고    scopus 로고
    • A. Shaw, How to measure HIFU output power properly, in: 5th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 829, 2006, pp. 628-632.
    • A. Shaw, How to measure HIFU output power properly, in: 5th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 829, 2006, pp. 628-632.
  • 60
    • 48149109613 scopus 로고    scopus 로고
    • A.J. Livett, The determination of acoustic output power by means of the radiation pressure balance, PhD thesis, University of London, 1984.
    • A.J. Livett, The determination of acoustic output power by means of the radiation pressure balance, PhD thesis, University of London, 1984.
  • 61
    • 0030149953 scopus 로고    scopus 로고
    • European intercomparison of ultrasonic power measurement
    • Beissner K., Oosterbahn W.A., Hekkenberg R.T., and Shaw A. European intercomparison of ultrasonic power measurement. Acustica 82 3 (1996) 450-458
    • (1996) Acustica , vol.82 , Issue.3 , pp. 450-458
    • Beissner, K.1    Oosterbahn, W.A.2    Hekkenberg, R.T.3    Shaw, A.4
  • 63
    • 33947162967 scopus 로고    scopus 로고
    • Interstitial devices for minimally invasive thermal ablation by high-intensity ultrasound
    • Lafon C., Melodelima D., Salomir R., and Chapelon Y.J. Interstitial devices for minimally invasive thermal ablation by high-intensity ultrasound. Int. J. Hyperthermia 23 2 (2007) 153-163
    • (2007) Int. J. Hyperthermia , vol.23 , Issue.2 , pp. 153-163
    • Lafon, C.1    Melodelima, D.2    Salomir, R.3    Chapelon, Y.J.4
  • 64
    • 33947125570 scopus 로고    scopus 로고
    • Clinical applications of focused ultrasound - the brain
    • Hynynen K., and Clement G. Clinical applications of focused ultrasound - the brain. Int. J. Hyperthermia 23 2 (2007) 193-202
    • (2007) Int. J. Hyperthermia , vol.23 , Issue.2 , pp. 193-202
    • Hynynen, K.1    Clement, G.2
  • 65
    • 34147182208 scopus 로고    scopus 로고
    • Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique
    • Maruvada S., Harris G.R., Herman B.A., and King R.L. Acoustic power calibration of high-intensity focused ultrasound transducers using a radiation force technique. J. Acoust. Soc. Am. 121 3 (2007) 1434-1439
    • (2007) J. Acoust. Soc. Am. , vol.121 , Issue.3 , pp. 1434-1439
    • Maruvada, S.1    Harris, G.R.2    Herman, B.A.3    King, R.L.4
  • 68
    • 0037458224 scopus 로고    scopus 로고
    • MRI-guided gas bubble enhanced in in vivo rabbit thigh
    • Sokka S.D., King R., and Hynynen K. MRI-guided gas bubble enhanced in in vivo rabbit thigh. Phys. Med. Biol. 4 (2003) 223-241
    • (2003) Phys. Med. Biol. , vol.4 , pp. 223-241
    • Sokka, S.D.1    King, R.2    Hynynen, K.3
  • 71
    • 48149097872 scopus 로고    scopus 로고
    • J.E. Kennedy, An assessment of the capacity of high-intensity focused ultrasound to treat tumours of the liver and kidney, Thesis submitted in part fulfilment of the requirements for the degree of Doctor of Philosophy, University of Oxford, 2004.
    • J.E. Kennedy, An assessment of the capacity of high-intensity focused ultrasound to treat tumours of the liver and kidney, Thesis submitted in part fulfilment of the requirements for the degree of Doctor of Philosophy, University of Oxford, 2004.
  • 72
    • 0021262046 scopus 로고
    • Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound
    • Bacon D.R. Finite amplitude distortion of the pulsed fields used in diagnostic ultrasound. Ultrasound Med. Biol. 10 (1984) 189-195
    • (1984) Ultrasound Med. Biol. , vol.10 , pp. 189-195
    • Bacon, D.R.1
  • 73
    • 0025833059 scopus 로고
    • Prediction of in situ exposure to ultrasound: an acoustical attenuation method
    • Preston R.C., Shaw A., and Zeqiri B. Prediction of in situ exposure to ultrasound: an acoustical attenuation method. Ultrasound Med. Biol. 17 (1991) 317-332
    • (1991) Ultrasound Med. Biol. , vol.17 , pp. 317-332
    • Preston, R.C.1    Shaw, A.2    Zeqiri, B.3
  • 74
    • 0026722073 scopus 로고
    • Nonlinear pressure fields due to focused circular apertures
    • Baker A.C. Nonlinear pressure fields due to focused circular apertures. J. Acoust. Soc. Am. 91 (1992) 713-717
    • (1992) J. Acoust. Soc. Am. , vol.91 , pp. 713-717
    • Baker, A.C.1
  • 75
    • 0004146551 scopus 로고    scopus 로고
    • Hamilton M.F., and Blackstock D.T. (Eds), Academic Press, San Diego
    • In: Hamilton M.F., and Blackstock D.T. (Eds). Nonlinear Acoustics (1998), Academic Press, San Diego
    • (1998) Nonlinear Acoustics
  • 76
    • 0023981196 scopus 로고
    • The NPL ultrasound beam calibrator
    • Preston R.C. The NPL ultrasound beam calibrator. IEEE Trans. UFFC 35 2 (1988) 122-139
    • (1988) IEEE Trans. UFFC , vol.35 , Issue.2 , pp. 122-139
    • Preston, R.C.1
  • 77
    • 48149092800 scopus 로고    scopus 로고
    • The NPL ultrasound beam calibrator - millennium edition
    • Shaw A., Preston R.C., and Halliday M. The NPL ultrasound beam calibrator - millennium edition. Eur. J. Ultrasound 8 (1998) S1
    • (1998) Eur. J. Ultrasound , vol.8
    • Shaw, A.1    Preston, R.C.2    Halliday, M.3
  • 78
    • 34548803488 scopus 로고    scopus 로고
    • S.M. Howard, C.I. Zanelli, HIFU transducer characterization using a robust needle hydrophone, in: 6th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 911, 2007, pp. 8-14.
    • S.M. Howard, C.I. Zanelli, HIFU transducer characterization using a robust needle hydrophone, in: 6th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 911, 2007, pp. 8-14.
  • 79
    • 4143085015 scopus 로고    scopus 로고
    • P. Kaczkowski, B. Cunitz, V. Khokhlova, O. Sapozhnikov, High resolution mapping of nonlinear MHz ultrasonic fields using a scanned scatterer, in: Proceedings of the IEEE Ultrasonics Symposium, 2003, pp. 982-985.
    • P. Kaczkowski, B. Cunitz, V. Khokhlova, O. Sapozhnikov, High resolution mapping of nonlinear MHz ultrasonic fields using a scanned scatterer, in: Proceedings of the IEEE Ultrasonics Symposium, 2003, pp. 982-985.
  • 80
    • 48149113119 scopus 로고    scopus 로고
    • M.E. Schafer, J. Gessert, W. Moore, Development of a high intensity focused ultrasound (HIFU) hydrophone system, in: 5th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, 2006, p. 893.
    • M.E. Schafer, J. Gessert, W. Moore, Development of a high intensity focused ultrasound (HIFU) hydrophone system, in: 5th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, 2006, p. 893.
  • 81
    • 34548752251 scopus 로고    scopus 로고
    • W. Wang, F. Ye, The measurement of HIFU field using a reflective needle hydrophone, in: 6th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 911, 2007, pp. 3-7.
    • W. Wang, F. Ye, The measurement of HIFU field using a reflective needle hydrophone, in: 6th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 911, 2007, pp. 3-7.
  • 82
    • 0027624596 scopus 로고
    • Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water
    • Staudenraus J., and Eisenmenger W. Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water. Ultrasonics 31 (1993) 267-273
    • (1993) Ultrasonics , vol.31 , pp. 267-273
    • Staudenraus, J.1    Eisenmenger, W.2
  • 83
    • 27644551519 scopus 로고    scopus 로고
    • Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz
    • Lewin P.A., Mu C., Umchid S., Daryoush A., and El-Sherif M.A. Acousto-optic, point receiver hydrophone probe for operation up to 100 MHz. Ultrasonics 43 10 (2005) 815-821
    • (2005) Ultrasonics , vol.43 , Issue.10 , pp. 815-821
    • Lewin, P.A.1    Mu, C.2    Umchid, S.3    Daryoush, A.4    El-Sherif, M.A.5
  • 84
    • 0033888678 scopus 로고    scopus 로고
    • Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: a comparison with PVDF needle and membrane hydrophones
    • Beard P.C., Hurrell A.M., and Mills T.N. Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: a comparison with PVDF needle and membrane hydrophones. IEEE Trans. UFFC 47 (2000) 256-264
    • (2000) IEEE Trans. UFFC , vol.47 , pp. 256-264
    • Beard, P.C.1    Hurrell, A.M.2    Mills, T.N.3
  • 85
    • 0037336435 scopus 로고    scopus 로고
    • Characterization of an optical multilayer hydrophone with constant frequency response in the range from 1 to 75 MHz
    • Wilkens V. Characterization of an optical multilayer hydrophone with constant frequency response in the range from 1 to 75 MHz. J. Acoust. Soc. Am. 113 3 (2003) 1431-1438
    • (2003) J. Acoust. Soc. Am. , vol.113 , Issue.3 , pp. 1431-1438
    • Wilkens, V.1
  • 86
    • 34548775667 scopus 로고    scopus 로고
    • D.A. Christensen, A. Chao, A pulsed Schlieren system for visualizing beams from phased-array HIFU applicators, in: 6th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 911, 2007, pp. 15-19.
    • D.A. Christensen, A. Chao, A pulsed Schlieren system for visualizing beams from phased-array HIFU applicators, in: 6th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 911, 2007, pp. 15-19.
  • 87
    • 33746362477 scopus 로고    scopus 로고
    • A simple Schlieren system for visualizing a sound field of pulsed ultrasound
    • Kudo N., Ouchi H., Yamamoto K., and Sekimizu H. A simple Schlieren system for visualizing a sound field of pulsed ultrasound. J. Phys.: Conf. Ser. 1 (2004) 146-149
    • (2004) J. Phys.: Conf. Ser. , vol.1 , pp. 146-149
    • Kudo, N.1    Ouchi, H.2    Yamamoto, K.3    Sekimizu, H.4
  • 88
    • 48149087081 scopus 로고    scopus 로고
    • IEC62127-1:2007, Ultrasonics - Hydrophone - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz, International Electrotechnical Commission, Geneva, Switzerland.
    • IEC62127-1:2007, Ultrasonics - Hydrophone - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz, International Electrotechnical Commission, Geneva, Switzerland.
  • 89
    • 48149096387 scopus 로고    scopus 로고
    • IEC62127-2:2007, Ultrasonics - Hydrophone - Part 2: Calibration of hydrophones to be used in ultrasonic fields up to 40 MHz, International Electrotechnical Commission, Geneva, Switzerland.
    • IEC62127-2:2007, Ultrasonics - Hydrophone - Part 2: Calibration of hydrophones to be used in ultrasonic fields up to 40 MHz, International Electrotechnical Commission, Geneva, Switzerland.
  • 90
    • 0024394352 scopus 로고
    • Are hydrophones of diameter 0.5 mm small enough to characterise diagnostic ultrasound equipment?
    • Smith R.A. Are hydrophones of diameter 0.5 mm small enough to characterise diagnostic ultrasound equipment?. Phys. Med. Biol. 3 (1989) 1593-1607
    • (1989) Phys. Med. Biol. , vol.3 , pp. 1593-1607
    • Smith, R.A.1
  • 91
    • 0026733535 scopus 로고
    • The influence of waveform distortion on hydrophone spatial-averaging corrections - Theory and measurement
    • Zeqiri B., and Bond A.D. The influence of waveform distortion on hydrophone spatial-averaging corrections - Theory and measurement. J. Acoust. Soc. Am. 92 (1992) 1809-1821
    • (1992) J. Acoust. Soc. Am. , vol.92 , pp. 1809-1821
    • Zeqiri, B.1    Bond, A.D.2
  • 92
    • 0142247356 scopus 로고    scopus 로고
    • Hydrophones' effective radius as a quasi-continuous function of frequency
    • Radulescu E.G., Lewin P.A., Nowicki A., and Berger W.A. Hydrophones' effective radius as a quasi-continuous function of frequency. Ultrasonics 41 8 (2003) 635-641
    • (2003) Ultrasonics , vol.41 , Issue.8 , pp. 635-641
    • Radulescu, E.G.1    Lewin, P.A.2    Nowicki, A.3    Berger, W.A.4
  • 93
    • 0038798100 scopus 로고    scopus 로고
    • Amplitude and phase calibration of hydrophones by heterodyne and time-gated time-delay spectrometry
    • Koch C. Amplitude and phase calibration of hydrophones by heterodyne and time-gated time-delay spectrometry. IEEE Trans. UFFC 50 (2003) 344-348
    • (2003) IEEE Trans. UFFC , vol.50 , pp. 344-348
    • Koch, C.1
  • 94
    • 2942667849 scopus 로고    scopus 로고
    • Amplitude and phase calibration of hydrophones up to 70 MHz using broadband pulse excitation and an optical reference hydrophone
    • Wilkens V., and Koch C. Amplitude and phase calibration of hydrophones up to 70 MHz using broadband pulse excitation and an optical reference hydrophone. J. Acoust. Soc. Am. 115 (2004) 2892-2903
    • (2004) J. Acoust. Soc. Am. , vol.115 , pp. 2892-2903
    • Wilkens, V.1    Koch, C.2
  • 95
    • 48149115695 scopus 로고    scopus 로고
    • Improvement of hydrophone measurements on diagnostic ultrasound machines using broadband complex-valued calibration data
    • Wilkens V., and Koch C. Improvement of hydrophone measurements on diagnostic ultrasound machines using broadband complex-valued calibration data. J. Phys.: Conf. Ser. 1 (2004) 50-55
    • (2004) J. Phys.: Conf. Ser. , vol.1 , pp. 50-55
    • Wilkens, V.1    Koch, C.2
  • 96
    • 13944263663 scopus 로고    scopus 로고
    • A theoretical model describing the transfer characteristics of a membrane hydrophone and validation
    • Gelat P.N., Preston R.C., and Hurrell A. A theoretical model describing the transfer characteristics of a membrane hydrophone and validation. Ultrasonics 43 (2005) 331-341
    • (2005) Ultrasonics , vol.43 , pp. 331-341
    • Gelat, P.N.1    Preston, R.C.2    Hurrell, A.3
  • 98
    • 0018153661 scopus 로고
    • Cross-spectral method of measuring acoustic intensity without error caused by instrument phase mismatch
    • Chung J.Y. Cross-spectral method of measuring acoustic intensity without error caused by instrument phase mismatch. J. Acoust. Soc. Am. 64 (1978) 1613-1616
    • (1978) J. Acoust. Soc. Am. , vol.64 , pp. 1613-1616
    • Chung, J.Y.1
  • 99
    • 48149093329 scopus 로고    scopus 로고
    • IEC61043:1993, Instruments for the measurement of sound intensity - Measurements with pairs of pressure sensing microphones, International Electrotechnical Commission, Geneva, 1993.
    • IEC61043:1993, Instruments for the measurement of sound intensity - Measurements with pairs of pressure sensing microphones, International Electrotechnical Commission, Geneva, 1993.
  • 100
    • 0032783943 scopus 로고    scopus 로고
    • Development of a velocity gradient underwater acoustic intensity sensor
    • Bastyra K.J., and Lauchle G.C. Development of a velocity gradient underwater acoustic intensity sensor. J. Acoust. Soc. Am. 106 6 (1999) 3178-3188
    • (1999) J. Acoust. Soc. Am. , vol.106 , Issue.6 , pp. 3178-3188
    • Bastyra, K.J.1    Lauchle, G.C.2
  • 101
    • 0742304438 scopus 로고    scopus 로고
    • The microflown: an acoustic particle velocity sensor
    • de Bree H.-E. The microflown: an acoustic particle velocity sensor. Acoust. Aust. 31 (2003) 91-94
    • (2003) Acoust. Aust. , vol.31 , pp. 91-94
    • de Bree, H.-E.1
  • 102
    • 24944549080 scopus 로고    scopus 로고
    • A comparison of two different sound intensity measurement principles
    • Facobsen F. A comparison of two different sound intensity measurement principles. J. Acoust. Soc. Am. 118 3 (2005) 1510-1517
    • (2005) J. Acoust. Soc. Am. , vol.118 , Issue.3 , pp. 1510-1517
    • Facobsen, F.1
  • 103
    • 48149101791 scopus 로고    scopus 로고
    • IEC61157:1992, Requirements for the declaration of the acoustic output of medical diagnostic ultrasonic equipment, International Electrotechnical Commission, Geneva, 1992.
    • IEC61157:1992, Requirements for the declaration of the acoustic output of medical diagnostic ultrasonic equipment, International Electrotechnical Commission, Geneva, 1992.
  • 104
    • 33947184321 scopus 로고    scopus 로고
    • Treatment monitoring and thermometry for therapeutic focused ultrasound
    • Rivens I.R., Shaw A., Civale J., and Morris H. Treatment monitoring and thermometry for therapeutic focused ultrasound. Int. J. Hyperthermia 23 2 (2007) 121-139
    • (2007) Int. J. Hyperthermia , vol.23 , Issue.2 , pp. 121-139
    • Rivens, I.R.1    Shaw, A.2    Civale, J.3    Morris, H.4
  • 105
    • 48149108051 scopus 로고    scopus 로고
    • IEC60601-2-37:2004, Ed. 1.1, Medical electrical equipment: particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment, International Electrotechnical Commission, Geneva, 2004.
    • IEC60601-2-37:2004, Ed. 1.1, Medical electrical equipment: particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment, International Electrotechnical Commission, Geneva, 2004.
  • 106
    • 48149089452 scopus 로고    scopus 로고
    • IEC62306:2005, Ultrasonics - Field characterisation - Test objects for determining temperature elevation in diagnostic ultrasound fields, International Electrotechnical Commission, Geneva, 2005.
    • IEC62306:2005, Ultrasonics - Field characterisation - Test objects for determining temperature elevation in diagnostic ultrasound fields, International Electrotechnical Commission, Geneva, 2005.
  • 107
    • 0033818660 scopus 로고    scopus 로고
    • Magnetic resonance temperature imaging for guidance of thermotherapy
    • Quesson B., De Zwart J.A., and Moonen C.T. Magnetic resonance temperature imaging for guidance of thermotherapy. J. Magnet. Reson. Imag. 12 (2000) 525-533
    • (2000) J. Magnet. Reson. Imag. , vol.12 , pp. 525-533
    • Quesson, B.1    De Zwart, J.A.2    Moonen, C.T.3
  • 108
    • 0028309802 scopus 로고
    • Tissue temperature monitoring for thermal interventional therapy: comparison of T1-weighted MR sequences
    • Matsumoto R., Mulkern R.V., Hushek S.G., and Jolesz F.A. Tissue temperature monitoring for thermal interventional therapy: comparison of T1-weighted MR sequences. J. Magnet. Reson. Imag. 4 1 (1994) 65-70
    • (1994) J. Magnet. Reson. Imag. , vol.4 , Issue.1 , pp. 65-70
    • Matsumoto, R.1    Mulkern, R.V.2    Hushek, S.G.3    Jolesz, F.A.4
  • 110
    • 31544467604 scopus 로고    scopus 로고
    • MR thermometry-based feedback control of efficacy and safety in minimum-time thermal therapies: phantom and in-vivo evaluations
    • Arora D., Cooley D., Perry T., Guo J., Richardson A., Moellmer J., et al. MR thermometry-based feedback control of efficacy and safety in minimum-time thermal therapies: phantom and in-vivo evaluations. Int. J. Hyperthermia 22 1 (2006) 29-42
    • (2006) Int. J. Hyperthermia , vol.22 , Issue.1 , pp. 29-42
    • Arora, D.1    Cooley, D.2    Perry, T.3    Guo, J.4    Richardson, A.5    Moellmer, J.6
  • 111
    • 0031886918 scopus 로고    scopus 로고
    • Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery
    • Kuroda K., Chung A.H., Hynynen K., and Jolesz F.A. Calibration of water proton chemical shift with temperature for noninvasive temperature imaging during focused ultrasound surgery. J. Magnet. Reson. Imag. 8 1 (1998) 175-181
    • (1998) J. Magnet. Reson. Imag. , vol.8 , Issue.1 , pp. 175-181
    • Kuroda, K.1    Chung, A.H.2    Hynynen, K.3    Jolesz, F.A.4
  • 113
    • 0033905694 scopus 로고    scopus 로고
    • Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits
    • McDannold N.J., King R.L., Jolesz F.A., and Hynynen K.H. Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. Radiology 216 2 (2000) 517-523
    • (2000) Radiology , vol.216 , Issue.2 , pp. 517-523
    • McDannold, N.J.1    King, R.L.2    Jolesz, F.A.3    Hynynen, K.H.4
  • 114
    • 0033977997 scopus 로고    scopus 로고
    • Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy
    • Wu T., Kendell K.R., Felmlee J.P., Lewis B.D., and Ehman R.L. Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy. Med. Phys. 27 1 (2000) 221-224
    • (2000) Med. Phys. , vol.27 , Issue.1 , pp. 221-224
    • Wu, T.1    Kendell, K.R.2    Felmlee, J.P.3    Lewis, B.D.4    Ehman, R.L.5
  • 115
    • 0021911812 scopus 로고
    • Thermal conduction errors of manganin-constantan thermocouple arrays
    • Dickinson R.J. Thermal conduction errors of manganin-constantan thermocouple arrays. Phys. Med. Biol. 30 5 (1984) 445-453
    • (1984) Phys. Med. Biol. , vol.30 , Issue.5 , pp. 445-453
    • Dickinson, R.J.1
  • 116
    • 30244463882 scopus 로고
    • Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes - Theory
    • Fry W.J., and Fry R.B. Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes - Theory. J. Acoust. Soc. Am. 26 3 (1954) 294-310
    • (1954) J. Acoust. Soc. Am. , vol.26 , Issue.3 , pp. 294-310
    • Fry, W.J.1    Fry, R.B.2
  • 117
    • 0025025369 scopus 로고
    • Errors resulting from finite beam width and sample dimensions in the determination of the ultrasonic-absorption coefficient
    • Drewniak J.L., Frizzell L.A., and Dunn F. Errors resulting from finite beam width and sample dimensions in the determination of the ultrasonic-absorption coefficient. J. Acoust. Soc. Am. 88 2 (1990) 967-977
    • (1990) J. Acoust. Soc. Am. , vol.88 , Issue.2 , pp. 967-977
    • Drewniak, J.L.1    Frizzell, L.A.2    Dunn, F.3
  • 118
    • 0027426940 scopus 로고
    • Experimental validation of predicted temperature rises in tissue mimicking materials
    • Bacon D.R., and Shaw A. Experimental validation of predicted temperature rises in tissue mimicking materials. Phys. Med. Biol. 38 (1993) 1647-1659
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1647-1659
    • Bacon, D.R.1    Shaw, A.2
  • 119
    • 48149109604 scopus 로고    scopus 로고
    • A. Shaw, N.M. Pay, R.C. Preston, Assessment of the likely thermal index values for pulsed Doppler ultrasonic equipment - Stage II: experimental assessment of scanner/transducer combinations, NPL Report CMAM 12, 1998. Available from: .
    • A. Shaw, N.M. Pay, R.C. Preston, Assessment of the likely thermal index values for pulsed Doppler ultrasonic equipment - Stage II: experimental assessment of scanner/transducer combinations, NPL Report CMAM 12, 1998. Available from: .
  • 120
    • 0032900111 scopus 로고    scopus 로고
    • A proposed standard thermal test object for medical ultrasound
    • Shaw A., Pay N.M., Preston R.C., and Bond A.D. A proposed standard thermal test object for medical ultrasound. UMB 25 (1999) 121-132
    • (1999) UMB , vol.25 , pp. 121-132
    • Shaw, A.1    Pay, N.M.2    Preston, R.C.3    Bond, A.D.4
  • 121
    • 0037314163 scopus 로고    scopus 로고
    • Heating caused by selected pulsed Doppler and physiotherapy ultrasound beams measured using thermal test objects
    • Atkins T.J., and Duck F.A. Heating caused by selected pulsed Doppler and physiotherapy ultrasound beams measured using thermal test objects. Eur. J. Ultrasound 16 3 (2003) 243-252
    • (2003) Eur. J. Ultrasound , vol.16 , Issue.3 , pp. 243-252
    • Atkins, T.J.1    Duck, F.A.2
  • 122
    • 33845467697 scopus 로고    scopus 로고
    • H.J. Morris, A. Shaw, I.H. Rivens, G.R. ter Haar, Temperature measurement in ex vivo bovine liver using fine-wire and thin-film thermocouples, in: 5th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 829, 2006, pp. 338-342.
    • H.J. Morris, A. Shaw, I.H. Rivens, G.R. ter Haar, Temperature measurement in ex vivo bovine liver using fine-wire and thin-film thermocouples, in: 5th International Symposium on Therapeutic Ultrasound, AIP Conference Proceedings, vol. 829, 2006, pp. 338-342.
  • 123
    • 48149107362 scopus 로고    scopus 로고
    • H.J. Morris, I.H. Rivens, A. Shaw, G.R. ter Haar, Investigation of the viscous heating artefact arising when using thermocouples in a focused ultrasound field, Ultrasound Med. Biol., submitted for publication.
    • H.J. Morris, I.H. Rivens, A. Shaw, G.R. ter Haar, Investigation of the viscous heating artefact arising when using thermocouples in a focused ultrasound field, Ultrasound Med. Biol., submitted for publication.
  • 124
    • 0038714531 scopus 로고    scopus 로고
    • Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
    • Dewhirst M.W., Viglianti B.L., Lora-Michiels M., Hanson M., and Hoopes P.J. Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia. Int. J. Hyperthermia 19 3 (2003) 267-294
    • (2003) Int. J. Hyperthermia , vol.19 , Issue.3 , pp. 267-294
    • Dewhirst, M.W.1    Viglianti, B.L.2    Lora-Michiels, M.3    Hanson, M.4    Hoopes, P.J.5
  • 125
    • 33751307018 scopus 로고    scopus 로고
    • Quantification of risk from fetal exposure to diagnostic ultrasound
    • Church C.C., and Miller M.W. Quantification of risk from fetal exposure to diagnostic ultrasound. Prog. Biophys. Molec. Biol. 93 (2007) 331-353
    • (2007) Prog. Biophys. Molec. Biol. , vol.93 , pp. 331-353
    • Church, C.C.1    Miller, M.W.2
  • 126
    • 33947117433 scopus 로고    scopus 로고
    • Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU)
    • Coussios C.C., Farny C.H., ter Haar G., and Roy R.A. Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU). Int. J. Hyperthermia 23 2 (2007) 105-120
    • (2007) Int. J. Hyperthermia , vol.23 , Issue.2 , pp. 105-120
    • Coussios, C.C.1    Farny, C.H.2    ter Haar, G.3    Roy, R.A.4
  • 127
    • 0028331504 scopus 로고
    • Lesion development in focused ultrasound surgery: a general model
    • Hill C.R., Rivens I., Vaughan G., and ter Haar G.R. Lesion development in focused ultrasound surgery: a general model. Ultrasound Med. Biol. 209 3 (1994) 259-269
    • (1994) Ultrasound Med. Biol. , vol.209 , Issue.3 , pp. 259-269
    • Hill, C.R.1    Rivens, I.2    Vaughan, G.3    ter Haar, G.R.4
  • 129
    • 0042199473 scopus 로고    scopus 로고
    • Preclinical development of noninvasive vascular occlusion with focused ultrasonic surgery for fetal therapy
    • Denbow M.L., Rivens I.H., Rowland I.J., Leach M.O., Fisk N.M., and ter Haar G.R. Preclinical development of noninvasive vascular occlusion with focused ultrasonic surgery for fetal therapy. Am. J. Obstet. Gynecol. 182 2 (2000) 387-392
    • (2000) Am. J. Obstet. Gynecol. , vol.182 , Issue.2 , pp. 387-392
    • Denbow, M.L.1    Rivens, I.H.2    Rowland, I.J.3    Leach, M.O.4    Fisk, N.M.5    ter Haar, G.R.6
  • 130
    • 4143128979 scopus 로고    scopus 로고
    • Effects of fascia lata on HIFU lesioning in vitro
    • Kun G., and Wan M. Effects of fascia lata on HIFU lesioning in vitro. Ultrasound in Med. Biol. 30 7 (2004) 991-998
    • (2004) Ultrasound in Med. Biol. , vol.30 , Issue.7 , pp. 991-998
    • Kun, G.1    Wan, M.2
  • 131
    • 0036692914 scopus 로고    scopus 로고
    • Reconstruction of ultrasonic fields by deconvolving the hydrophone aperture effects: I. Theory and simulation
    • Boutkedjirt T., and Reibold R. Reconstruction of ultrasonic fields by deconvolving the hydrophone aperture effects: I. Theory and simulation. Ultrasonics 39 9 (2002) 631-639
    • (2002) Ultrasonics , vol.39 , Issue.9 , pp. 631-639
    • Boutkedjirt, T.1    Reibold, R.2
  • 132
    • 0036693611 scopus 로고    scopus 로고
    • Reconstruction of ultrasonic fields by deconvolving the hydrophone aperture effects: II. Experiment
    • Boutkedjirt T., and Reibold R. Reconstruction of ultrasonic fields by deconvolving the hydrophone aperture effects: II. Experiment. Ultrasonics 39 9 (2002) 641-648
    • (2002) Ultrasonics , vol.39 , Issue.9 , pp. 641-648
    • Boutkedjirt, T.1    Reibold, R.2
  • 133
    • 48149091420 scopus 로고    scopus 로고
    • P. Theobald, A.D. Thompson, S.P. Robinson, R.C. Preston, P. Lepper, C. Swift, W. Yuebing, J. Tyrer, Fundamental standards for acoustics based on optical methods - phase three report for sound in water, NPL Report CAIR 9, January 2004. Available from: .
    • P. Theobald, A.D. Thompson, S.P. Robinson, R.C. Preston, P. Lepper, C. Swift, W. Yuebing, J. Tyrer, Fundamental standards for acoustics based on optical methods - phase three report for sound in water, NPL Report CAIR 9, January 2004. Available from: .
  • 135
    • 48149096546 scopus 로고    scopus 로고
    • P.C.M. Galloway, R.C. Preston, D.R. Bacon, Velocity interferometer for measurement of high-amplitude acoustic pulses, in: Proceedings of the 1995 World Congress of Ultrasonics, Berlin, Part 2, 1995, pp. 935-938.
    • P.C.M. Galloway, R.C. Preston, D.R. Bacon, Velocity interferometer for measurement of high-amplitude acoustic pulses, in: Proceedings of the 1995 World Congress of Ultrasonics, Berlin, Part 2, 1995, pp. 935-938.
  • 136
    • 0013232914 scopus 로고    scopus 로고
    • Non-invasive measurements of underwater pressure fields using laser Doppler velocimetry
    • Harland A.R., Petzing J.N., and Tyrer J.R. Non-invasive measurements of underwater pressure fields using laser Doppler velocimetry. J. Sound Vibr. 252 1 (2002) 169-177
    • (2002) J. Sound Vibr. , vol.252 , Issue.1 , pp. 169-177
    • Harland, A.R.1    Petzing, J.N.2    Tyrer, J.R.3
  • 137
    • 0033674471 scopus 로고    scopus 로고
    • Three-dimensional optical measurement of instantaneous pressure
    • Pitts T.A., and Greenleaf J.F. Three-dimensional optical measurement of instantaneous pressure. J. Acoust. Soc. Am. 108 6 (2000) 2873-2883
    • (2000) J. Acoust. Soc. Am. , vol.108 , Issue.6 , pp. 2873-2883
    • Pitts, T.A.1    Greenleaf, J.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.