-
1
-
-
33748053995
-
-
Standards Publication UD 2-2003, National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn VA 22209
-
Acoustic Output Measurement Standard for Diagnostic Ultrasound Equipment, Revision 1, Standards Publication UD 2-2003, National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn VA 22209, 2003.
-
(2003)
Acoustic Output Measurement Standard for Diagnostic Ultrasound Equipment, Revision 1
-
-
-
2
-
-
0003978799
-
-
Center for Devices and Radiological Health, FDA and revised in 1989, 1990, 1991, 1993, 1994, 1997
-
Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers, Center for Devices and Radiological Health, FDA, 1985, and revised in 1989, 1990, 1991, 1993, 1994, 1997.
-
(1985)
Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers
-
-
-
3
-
-
27644579191
-
-
Standards Publication UD 3-2003, National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn VA 22209
-
Standard for Real-Time Display of Thermal and Mechanical Acoustic Output Indices on Diagnostic Ultrasound Equipment, Revision 2, Standards Publication UD 3-2003, National Electrical Manufacturers Association, 1300 North 17th Street, Suite 1847, Rosslyn VA 22209, 2003.
-
(2003)
Standard for Real-time Display of Thermal and Mechanical Acoustic Output Indices on Diagnostic Ultrasound Equipment, Revision 2
-
-
-
4
-
-
0032033723
-
Evaluation of acoustical parameter sensitivity to age-related and ostearthritic changes in articular cartilage using 50 MHz ultrasound
-
E. Cherin, A. Saed, P. Laugier, P. Netter, and G. Berger Evaluation of acoustical parameter sensitivity to age-related and ostearthritic changes in articular cartilage using 50 MHz ultrasound Ultrasound Med. Biol. 24 1998 341 354
-
(1998)
Ultrasound Med. Biol.
, vol.24
, pp. 341-354
-
-
Cherin, E.1
Saed, A.2
Laugier, P.3
Netter, P.4
Berger, G.5
-
5
-
-
0032033474
-
Imaging and spectrum analysis of contrast agents in the in-vivo rabbit eye using very-high-frequency ultrasound
-
C.X. Dneg, F.C. Lizzi, R.H. Silverman, R. Ursea, and D.J. Coleman Imaging and spectrum analysis of contrast agents in the in-vivo rabbit eye using very-high-frequency ultrasound Ultrasound Med. Biol. 24 1998 383 394
-
(1998)
Ultrasound Med. Biol.
, vol.24
, pp. 383-394
-
-
Dneg, C.X.1
Lizzi, F.C.2
Silverman, R.H.3
Ursea, R.4
Coleman, D.J.5
-
6
-
-
0033982797
-
Sonographic depiction of tumor vascularity and flow from in-vivo models to clinical applications
-
A. Fleischer Sonographic depiction of tumor vascularity and flow from in-vivo models to clinical applications J. Ultrasound Med. 19 2000 55 61
-
(2000)
J. Ultrasound Med.
, vol.19
, pp. 55-61
-
-
Fleischer, A.1
-
7
-
-
0026719578
-
In vitro high resolution intravascular imaging in muscular and elastic arteries
-
G.R. Lockwood, L.R. Ryan, A.I. Gotlieb, E. Lonn, J.W. Hunt, P. Liu, and F.S. Foster In vitro high resolution intravascular imaging in muscular and elastic arteries J. Am. Coll. Cardiol. 20 1992 153
-
(1992)
J. Am. Coll. Cardiol.
, vol.20
, pp. 153
-
-
Lockwood, G.R.1
Ryan, L.R.2
Gotlieb, A.I.3
Lonn, E.4
Hunt, J.W.5
Liu, P.6
Foster, F.S.7
-
8
-
-
0028084929
-
Epithelial corneal thickness measurements by high frequency ultrasound digital signal processing
-
D.Z. Reinstein, R.H. Silverman, M.J. Rondeau, and D.J. Coleman Epithelial corneal thickness measurements by high frequency ultrasound digital signal processing Ophthalmology 101 1994 140
-
(1994)
Ophthalmology
, vol.101
, pp. 140
-
-
Reinstein, D.Z.1
Silverman, R.H.2
Rondeau, M.J.3
Coleman, D.J.4
-
9
-
-
0028896445
-
A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging
-
D.H. Turnbull, B.G. Starkoski, K.A. Harasiewicz, J.L. Semple, L. From L, A.K. Gupta, D.N. Sauder, and F.S. Foster A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging Ultrasound Med. Biol. 21 1995 79
-
(1995)
Ultrasound Med. Biol.
, vol.21
, pp. 79
-
-
Turnbull, D.H.1
Starkoski, B.G.2
Harasiewicz, K.A.3
Semple, J.L.4
From, L.L.5
Gupta, A.K.6
Sauder, D.N.7
Foster, F.S.8
-
10
-
-
0027664734
-
Principles and applications of ultrasound backscatter microscopy
-
F.S. Foster, C.J. Pavlin, G.R. Lockwood, L.K. Ryan, L.B. Harasiewicz, and A.M. Rauth Principles and applications of ultrasound backscatter microscopy IEEE Trans. UFFC 40 1993 608
-
(1993)
IEEE Trans. UFFC
, vol.40
, pp. 608
-
-
Foster, F.S.1
Pavlin, C.J.2
Lockwood, G.R.3
Ryan, L.K.4
Harasiewicz, L.B.5
Rauth, A.M.6
-
11
-
-
0030196861
-
A 100 MHz ultrasonic imaging system for dermatologic and ophthalmologic diagnostics
-
C. Passman, and H. Emert A 100 MHz ultrasonic imaging system for dermatologic and ophthalmologic diagnostics IEEE Trans. UFFC 43 1996 545
-
(1996)
IEEE Trans. UFFC
, vol.43
, pp. 545
-
-
Passman, C.1
Emert, H.2
-
12
-
-
84944294183
-
Interfacing very-high frequency transducers to digital-acquisition scanning systems
-
F.L. Lizzi, M.C. Rorke, J.B. Sokil-Melgar, A. Kalisz, and J. Driller Interfacing very-high frequency transducers to digital-acquisition scanning systems Proc. SPIE 1844 1992 313
-
(1992)
Proc. SPIE
, vol.1844
, pp. 313
-
-
Lizzi, F.L.1
Rorke, M.C.2
Sokil-Melgar, J.B.3
Kalisz, A.4
Driller, J.5
-
14
-
-
0029735579
-
Estimation of blood velocity with high frequency ultrasound
-
K. Ferrara, B.G. Zagar, R.H. Silverman, J.B. Sokil-Melgar, and I.M. Aslanidis Estimation of blood velocity with high frequency ultrasound IEEE Ultrasonics Trans. UFFC 43 1 1996 149 157
-
(1996)
IEEE Ultrasonics Trans. UFFC
, vol.43
, Issue.1
, pp. 149-157
-
-
Ferrara, K.1
Zagar, B.G.2
Silverman, R.H.3
Sokil-Melgar, J.B.4
Aslanidis, I.M.5
-
15
-
-
0037277864
-
High frequency 3D color flow imaging of the microcirculation
-
D.E. Goertz, J.L. Yu, R.S. Kerbel, P.N. Burns, and F.S. Foster High frequency 3D color flow imaging of the microcirculation Ultrasound Med. Biol. 29 1 2003 39 51
-
(2003)
Ultrasound Med. Biol.
, vol.29
, Issue.1
, pp. 39-51
-
-
Goertz, D.E.1
Yu, J.L.2
Kerbel, R.S.3
Burns, P.N.4
Foster, F.S.5
-
16
-
-
0036750352
-
A new ultrasound instrument for in vivo microimaging of mice
-
F.S. Foster, M.Y. Zhang, Y.Q. Zhou, G. Liu, J. Mehi, K.A. Harasiewicz, B.G. Starkoski, L. Zan, D.A. Knapik, and S.L. Adamson A new ultrasound instrument for in vivo microimaging of mice Ultrasound Med. Biol. 28 2002 1165 1172
-
(2002)
Ultrasound Med. Biol.
, vol.28
, pp. 1165-1172
-
-
Foster, F.S.1
Zhang, M.Y.2
Zhou, Y.Q.3
Liu, G.4
Mehi, J.5
Harasiewicz, K.A.6
Starkoski, B.G.7
Zan, L.8
Knapik, D.A.9
Adamson, S.L.10
-
17
-
-
0037077429
-
Applications for multifrequency ultrasound biomicroscopy in mice from implantation to adulthood
-
Y.Q. Zhou, F.S. Foster, D.W. Qu, M. Zhang, K.A. Harasiewicz, and S.L. Adamson Applications for multifrequency ultrasound biomicroscopy in mice from implantation to adulthood Physiol. Genomics 10 2002 113 126
-
(2002)
Physiol. Genomics
, vol.10
, pp. 113-126
-
-
Zhou, Y.Q.1
Foster, F.S.2
Qu, D.W.3
Zhang, M.4
Harasiewicz, K.A.5
Adamson, S.L.6
-
18
-
-
0034314458
-
A novel method for determining calibration and behavior of PVDF ultrasonic hydrophone probes in the frequency range up to 100 MHz
-
H. Bleeker, and P.A. Lewin A novel method for determining calibration and behavior of PVDF ultrasonic hydrophone probes in the frequency range up to 100 MHz IEEE Trans. UFFC 47 6 2000 1354 1362
-
(2000)
IEEE Trans. UFFC
, vol.47
, Issue.6
, pp. 1354-1362
-
-
Bleeker, H.1
Lewin, P.A.2
-
19
-
-
0027624596
-
Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water
-
J. Staudenraus, and W. Eisenmenger Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water Ultrasonics 31 4 1993 267 273
-
(1993)
Ultrasonics
, vol.31
, Issue.4
, pp. 267-273
-
-
Staudenraus, J.1
Eisenmenger, W.2
-
20
-
-
0016433599
-
Propagation effects in optical fibers
-
D. Gloge Propagation effects in optical fibers IEEE Trans. Microwave Theory Tech. 23 1975 106 120
-
(1975)
IEEE Trans. Microwave Theory Tech.
, vol.23
, pp. 106-120
-
-
Gloge, D.1
-
21
-
-
0009528379
-
Efficient power coupling using taper-ended multimode optical fibres
-
T. Ozeki, and B. Kawasaki Efficient power coupling using taper-ended multimode optical fibres Electron. Lett. 12 1976 607 608
-
(1976)
Electron. Lett.
, vol.12
, pp. 607-608
-
-
Ozeki, T.1
Kawasaki, B.2
-
22
-
-
0015625923
-
Measurement of refractive index of water under high dynamic pressures
-
H.S. Yadav, and D.S. Murty Measurement of refractive index of water under high dynamic pressures J. Appl. Phys. 44 1973 2197 2200
-
(1973)
J. Appl. Phys.
, vol.44
, pp. 2197-2200
-
-
Yadav, H.S.1
Murty, D.S.2
-
23
-
-
0014852030
-
Shock-wave studies PMMA of fused slica and sapphire
-
L.M. Barker, and R.E. Hollenback Shock-wave studies PMMA of fused slica and sapphire J. Appl. Phys. 41 1970 4208 4226
-
(1970)
J. Appl. Phys.
, vol.41
, pp. 4208-4226
-
-
Barker, L.M.1
Hollenback, R.E.2
-
24
-
-
0037507373
-
Calibration of ultrasonic hydrophone probes up to 100 MHz using time gating frequency analysis and finite amplitude waves
-
E.G. Radulescu, J. Wojcik, P.A. Lewin, and A. Nowicki Calibration of ultrasonic hydrophone probes up to 100 MHz using time gating frequency analysis and finite amplitude waves Ultrasonics 41 4 2003 247 253
-
(2003)
Ultrasonics
, vol.41
, Issue.4
, pp. 247-253
-
-
Radulescu, E.G.1
Wojcik, J.2
Lewin, P.A.3
Nowicki, A.4
-
25
-
-
23244438864
-
Broadband fiber optic ultrasound hydrophone probe
-
Palisades NY, October
-
C. Mu, S. Umichid, L. Bansal, A. Daryoush, P. Lewin, M. El-Sherif, Broadband fiber optic ultrasound hydrophone probe, IEEE Lightwave Technologies in Instrumentation and Measurement Conference, Palisades NY, October 2004, pp. 149-152.
-
(2004)
IEEE Lightwave Technologies in Instrumentation and Measurement Conference
, pp. 149-152
-
-
Mu, C.1
Umichid, S.2
Bansal, L.3
Daryoush, A.4
Lewin, P.5
El-Sherif, M.6
-
26
-
-
0023981195
-
Calibration of medical ultrasonic equipment-procedures and accuracy assessment
-
R.C. Preston, D.R. Bacon, and R.A. Smith Calibration of medical ultrasonic equipment-procedures and accuracy assessment IEEE Trans. UFFC 35 2 1988 110 121
-
(1988)
IEEE Trans. UFFC
, vol.35
, Issue.2
, pp. 110-121
-
-
Preston, R.C.1
Bacon, D.R.2
Smith, R.A.3
-
27
-
-
0033276975
-
Primary calibration of hydrophones with extended frequency range 1-70 MHz using optical interferometry
-
C. Koch, and W. Molkenstruck Primary calibration of hydrophones with extended frequency range 1-70 MHz using optical interferometry IEEE Trans. UFFC 46 5 1999 1303 1314
-
(1999)
IEEE Trans. UFFC
, vol.46
, Issue.5
, pp. 1303-1314
-
-
Koch, C.1
Molkenstruck, W.2
-
28
-
-
27644467155
-
Phase calibration of hydrophones: Heterodyne time-delay spectrometry and broadband pulse technique using an optical reference hydrophone
-
C. Koch, and V. Wilkens Phase calibration of hydrophones: heterodyne time-delay spectrometry and broadband pulse technique using an optical reference hydrophone J. Phys. CS 1 2004 14 19
-
(2004)
J. Phys. CS
, vol.1
, pp. 14-19
-
-
Koch, C.1
Wilkens, V.2
|