메뉴 건너뛰기




Volumn 18, Issue 7, 2008, Pages

On-chip liquid storage and dispensing for lab-on-a-chip applications

Author keywords

[No Author keywords available]

Indexed keywords

BUFFER STORAGE; HEALTH; INJECTION (OIL WELLS); LIQUIDS; PARAFFIN WAXES; PARAFFINS; SOLUTIONS; WASHING; WELL FLOODING;

EID: 47249148863     PISSN: 09601317     EISSN: 13616439     Source Type: Journal    
DOI: 10.1088/0960-1317/18/7/075036     Document Type: Article
Times cited : (27)

References (17)
  • 1
    • 0037096666 scopus 로고    scopus 로고
    • Micro total analysis systems. 1. Introduction, theory and technology
    • Reyes D, Iossifidis D, Auroux P and Manz 2002 Micro total analysis systems. 1. Introduction, theory and technology Anal. Chem. 74 2623-36
    • (2002) Anal. Chem. , vol.74 , Issue.12 , pp. 2623-2636
    • Reyes, D.1    Iossifidis, D.2    Auroux, P.3    Manz4
  • 2
    • 33845910922 scopus 로고    scopus 로고
    • Lab-on-chip for global health: Past studies and future opportunities
    • Chin C D, Linder V and Sia S K 2007 Lab-on-chip for global health: past studies and future opportunities Lab Chip 7 41-57
    • (2007) Lab Chip , vol.7 , Issue.1 , pp. 41-57
    • Chin, C.D.1    Linder, V.2    Sia, S.K.3
  • 3
    • 0002222889 scopus 로고    scopus 로고
    • Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry
    • Tüds A J, Besselink G A J and Schasfoort R B M 2001 Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistry Lab Chip 1 83-95
    • (2001) Lab Chip , vol.1 , Issue.2 , pp. 83-95
    • Tüds, A.J.1    Besselink, G.A.J.2    Schasfoort, R.B.M.3
  • 6
    • 21844471002 scopus 로고    scopus 로고
    • Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
    • von Lode P 2005 Point-of-care immunotesting: approaching the analytical performance of central laboratory methods Clin. Biochem. 38 591-606
    • (2005) Clin. Biochem. , vol.38 , Issue.7 , pp. 591-606
    • Von Lode, P.1
  • 7
    • 1842477059 scopus 로고    scopus 로고
    • Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection
    • Liu R H, Yang J, Lenigk R, Bonanno J and Grodzinski P 2004 Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection Anal. Chem. 76 1824-31
    • (2004) Anal. Chem. , vol.76 , Issue.7 , pp. 1824-1831
    • Liu, R.H.1    Yang, J.2    Lenigk, R.3    Bonanno, J.4    Grodzinski, P.5
  • 9
    • 33845986752 scopus 로고    scopus 로고
    • A disposable lab-on-a-chip platform with embedded fluid actuators for active nanoliter liquid handling
    • Samel B, Nock V, Russom A, Griss P and Stemme G 2007 A disposable lab-on-a-chip platform with embedded fluid actuators for active nanoliter liquid handling Biomed. Microdevices 9 61-7
    • (2007) Biomed. Microdevices , vol.9 , Issue.1 , pp. 61-67
    • Samel, B.1    Nock, V.2    Russom, A.3    Griss, P.4    Stemme, G.5
  • 10
    • 0037060122 scopus 로고    scopus 로고
    • Sample pretreatment on microfabricated devices
    • Lichtenberg J, De Rooij N F and Verpoorte E 2002 Sample pretreatment on microfabricated devices Talanta 56 233-66
    • (2002) Talanta , vol.56 , Issue.2 , pp. 233-266
    • Lichtenberg, J.1    De Rooij, N.F.2    Verpoorte, E.3
  • 11
    • 11844250557 scopus 로고    scopus 로고
    • Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices
    • Linder V, Sia S K and Whitesides G M 2005 Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices Anal. Chem. 77 64-71
    • (2005) Anal. Chem. , vol.77 , Issue.1 , pp. 64-71
    • Linder, V.1    Sia, S.K.2    Whitesides, G.M.3
  • 12
    • 47249160467 scopus 로고    scopus 로고
    • Micro-sequential injection: A multipurpose lab-on-valve for the advancement of bioanalytical assays
    • Scampavia L D and Ruzicka J 2001 Micro-sequential injection: a multipurpose lab-on-valve for the advancement of bioanalytical assays Anal. Sci. Suppl. 17 i429-30
    • (2001) Anal. Sci. Suppl. , vol.17
    • Scampavia, L.D.1    Ruzicka, J.2
  • 13
    • 0033707028 scopus 로고    scopus 로고
    • Paraffin actuated surface micromachined valves
    • Carlen E T and Mastrangelo C H 2000 Paraffin actuated surface micromachined valves Proc. MEMS pp 381-5
    • (2000) Proc. MEMS , pp. 381-385
    • Carlen, E.T.1    Mastrangelo, C.H.2
  • 15
    • 2542510078 scopus 로고    scopus 로고
    • A closed-loop controlled electrochemically actuated micro-dosing system
    • Böhm S, Timmer B, Olthuis W and Bergveld P 2000 A closed-loop controlled electrochemically actuated micro-dosing system J. Micromech. Microeng. 10 498-504
    • (2000) J. Micromech. Microeng. , vol.10 , Issue.4 , pp. 498-504
    • Böhm, S.1    Timmer, B.2    Olthuis, W.3    Bergveld, P.4
  • 16
    • 47249128764 scopus 로고    scopus 로고
    • Lehto M 2007 Paraffin Actuators in Microfluidic Systems (Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology vol 325) (Uppsala: Acta Universitatis Upsaliensis) http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-8165
    • (2007) Paraffin Actuators in Microfluidic Systems
    • Lehto, M.1
  • 17
    • 0344737989 scopus 로고    scopus 로고
    • Solvent compatibility of poly(dimethylsiloxane)-based microfluidic devices
    • Lee J N, Park C and Whitesides G M 2003 Solvent compatibility of poly(dimethylsiloxane)-based microfluidic devices Anal. Chem. 75 6544-54
    • (2003) Anal. Chem. , vol.75 , Issue.23 , pp. 6544-6554
    • Lee, J.N.1    Park, C.2    Whitesides, G.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.