-
1
-
-
0032466576
-
Valve related complications in elderly patients with biological and mechanical aortic valves
-
Milano A., Guglieimi C., De Carlo M., et al. Valve related complications in elderly patients with biological and mechanical aortic valves. Ann Thorac Surg 66 Suppl (1998) S82-S87
-
(1998)
Ann Thorac Surg
, vol.66
, Issue.SUPPL
-
-
Milano, A.1
Guglieimi, C.2
De Carlo, M.3
-
2
-
-
0010955435
-
Bioprosthetic versus mechanical prostheses for aortic valve replacement in the elderly
-
Davis E.A., Greene P.S., Cameron D.E., et al. Bioprosthetic versus mechanical prostheses for aortic valve replacement in the elderly. Circulation 94 Suppl (1996) II-121-II-125
-
(1996)
Circulation
, vol.94
, Issue.SUPPL
, pp. 121-125
-
-
Davis, E.A.1
Greene, P.S.2
Cameron, D.E.3
-
3
-
-
0042859863
-
Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
-
Blais C., Dumesnil J.G., Baillot R., Simard S., Doyle D., and Pibarot P.H. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108 (2003) 983-988
-
(2003)
Circulation
, vol.108
, pp. 983-988
-
-
Blais, C.1
Dumesnil, J.G.2
Baillot, R.3
Simard, S.4
Doyle, D.5
Pibarot, P.H.6
-
4
-
-
33644858444
-
Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
-
Tasca G., Mhagna Z., Perotti S., et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 113 (2006) 570-576
-
(2006)
Circulation
, vol.113
, pp. 570-576
-
-
Tasca, G.1
Mhagna, Z.2
Perotti, S.3
-
5
-
-
0034619384
-
Prosthesis-patient mismatch affects survival after aortic valve replacement
-
Rao V., Jamieson W.R., Ivanov J., et al. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 102 Suppl 3 (2000) 5-9
-
(2000)
Circulation
, vol.102
, Issue.SUPPL. 3
, pp. 5-9
-
-
Rao, V.1
Jamieson, W.R.2
Ivanov, J.3
-
6
-
-
0028989106
-
The CarboMedics "Top Hat" supraannular prosthesis in the small aortic root
-
Rödler S., Moritz A., Wutte M., Hoda R., and Wolner E. The CarboMedics "Top Hat" supraannular prosthesis in the small aortic root. J Cardiac Surg 10 (1995) 198-204
-
(1995)
J Cardiac Surg
, vol.10
, pp. 198-204
-
-
Rödler, S.1
Moritz, A.2
Wutte, M.3
Hoda, R.4
Wolner, E.5
-
7
-
-
0342276117
-
Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis
-
Rödler S., Moritz A., Schreiner W., End A., Dubsky P., and Wolner E. Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis. Ann Thorac Surg 63 (1997) 1018-1025
-
(1997)
Ann Thorac Surg
, vol.63
, pp. 1018-1025
-
-
Rödler, S.1
Moritz, A.2
Schreiner, W.3
End, A.4
Dubsky, P.5
Wolner, E.6
-
8
-
-
0032801163
-
European system for cardiac operative risk evaluation (EuroSCORE)
-
Nashef S.A., Roques F., Michel P., Gauducheau E., Lemeshow S., and Salomon R. European system for cardiac operative risk evaluation (EuroSCORE). Eur J Cardiothorac Surg 16 (1999) 9-13
-
(1999)
Eur J Cardiothorac Surg
, vol.16
, pp. 9-13
-
-
Nashef, S.A.1
Roques, F.2
Michel, P.3
Gauducheau, E.4
Lemeshow, S.5
Salomon, R.6
-
9
-
-
0037998090
-
Logistic or additive EuroSCORE for high-risk patients?
-
Michel P., Roques F., and Nashef S.A. Logistic or additive EuroSCORE for high-risk patients?. Eur J Cardiothorac Surg 23 (2003) 684-687
-
(2003)
Eur J Cardiothorac Surg
, vol.23
, pp. 684-687
-
-
Michel, P.1
Roques, F.2
Nashef, S.A.3
-
10
-
-
14244252089
-
A 10-year experience with the CarboMedics cardiac prosthesis
-
Tominaga R., Kurisu K., Ochiai Y., et al. A 10-year experience with the CarboMedics cardiac prosthesis. Ann Thorac Surg 79 (2005) 784-789
-
(2005)
Ann Thorac Surg
, vol.79
, pp. 784-789
-
-
Tominaga, R.1
Kurisu, K.2
Ochiai, Y.3
-
11
-
-
33846926368
-
Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve
-
Aagaard J., and Geha A.S. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve. J Heart Valve Dis 16 (2007) 84-90
-
(2007)
J Heart Valve Dis
, vol.16
, pp. 84-90
-
-
Aagaard, J.1
Geha, A.S.2
-
13
-
-
0026717861
-
Hemodynamic evaluation by Doppler cardiography of small (less than or equal to 21 mm) prostheses and bioprostheses in the aortic valve position
-
Wiseth R., Levang O.W., Sande E., Tangen G., Skjaerpe T., and Hatle L. Hemodynamic evaluation by Doppler cardiography of small (less than or equal to 21 mm) prostheses and bioprostheses in the aortic valve position. Am J Cardiol 70 (1992) 240-246
-
(1992)
Am J Cardiol
, vol.70
, pp. 240-246
-
-
Wiseth, R.1
Levang, O.W.2
Sande, E.3
Tangen, G.4
Skjaerpe, T.5
Hatle, L.6
-
14
-
-
0041854625
-
Assessment of mechanical aortic valve prosthesis by means of Doppler echocardiography. What to measure and why?
-
Vannan M.A., and Sarkar K. Assessment of mechanical aortic valve prosthesis by means of Doppler echocardiography. What to measure and why?. J Thorac Cardiovasc Surg 126 (2003) 317-320
-
(2003)
J Thorac Cardiovasc Surg
, vol.126
, pp. 317-320
-
-
Vannan, M.A.1
Sarkar, K.2
-
15
-
-
33751441079
-
The influence of prosthesis size and design on exercise dynamics after aortic valve replacement
-
Ali N.F., Mahadevan V.S., Muir A., et al. The influence of prosthesis size and design on exercise dynamics after aortic valve replacement. J Heart Valve Dis 15 (2006) 755-762
-
(2006)
J Heart Valve Dis
, vol.15
, pp. 755-762
-
-
Ali, N.F.1
Mahadevan, V.S.2
Muir, A.3
-
16
-
-
22544479420
-
Validation and refinement of mortality risk models for heart valve surgery
-
Jin R., Grunkemeier G.L., and Starr A. Validation and refinement of mortality risk models for heart valve surgery. Ann Thorac Surg 80 (2005) 471-479
-
(2005)
Ann Thorac Surg
, vol.80
, pp. 471-479
-
-
Jin, R.1
Grunkemeier, G.L.2
Starr, A.3
-
17
-
-
0035115632
-
Aortic valve replacement in geriatric patients: determinants of in-hospital mortality
-
Bloomstein L.Z., Gielchinsky I., Bernestein A.D., et al. Aortic valve replacement in geriatric patients: determinants of in-hospital mortality. Ann Thorac Surg 71 (2001) 597-600
-
(2001)
Ann Thorac Surg
, vol.71
, pp. 597-600
-
-
Bloomstein, L.Z.1
Gielchinsky, I.2
Bernestein, A.D.3
-
18
-
-
33847323002
-
Effect of prior valve type on mortality in reoperative valve surgery
-
Tang G.H., Maganti M., David T., et al. Effect of prior valve type on mortality in reoperative valve surgery. Ann Thorac Surg 83 (2007) 938-945
-
(2007)
Ann Thorac Surg
, vol.83
, pp. 938-945
-
-
Tang, G.H.1
Maganti, M.2
David, T.3
-
19
-
-
0028831740
-
Reoperation on prosthetic heart valves. Patient-specific estimates of in-hospital events
-
Piehler J.M., Blackstone E.H., Bailey K.R., et al. Reoperation on prosthetic heart valves. Patient-specific estimates of in-hospital events. J Thorac Cardiovasc Surg 109 (1995) 30-48
-
(1995)
J Thorac Cardiovasc Surg
, vol.109
, pp. 30-48
-
-
Piehler, J.M.1
Blackstone, E.H.2
Bailey, K.R.3
-
21
-
-
4444324517
-
Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves
-
Bottio T., Caprilli L., Casarotto D., and Gerosa G. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves. J Thorac Cardiovasc Surg 128 (2004) 457-462
-
(2004)
J Thorac Cardiovasc Surg
, vol.128
, pp. 457-462
-
-
Bottio, T.1
Caprilli, L.2
Casarotto, D.3
Gerosa, G.4
-
22
-
-
20444406866
-
EuroSCORE predicts long-term mortality after heart valve surgery
-
Toumpoulis K., Anagnostopopoulos E., Toumpoulis S.K., DeRose J.J., and Swistel D. EuroSCORE predicts long-term mortality after heart valve surgery. Ann Thorac Surg 79 (2005) 1902-1908
-
(2005)
Ann Thorac Surg
, vol.79
, pp. 1902-1908
-
-
Toumpoulis, K.1
Anagnostopopoulos, E.2
Toumpoulis, S.K.3
DeRose, J.J.4
Swistel, D.5
|