Volumn 86, Issue 1, 2008, Pages 64-70

Mechanical Aortic Valve Prostheses in the Small Aortic Root: Top Hat Versus Standard CarboMedics Aortic Valve

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA ROOT; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ARTICLE; CARBOMEDICS PROSTHETIC HEART VALVE; CONFIDENCE INTERVAL; CONTROLLED STUDY; ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HAZARD RATIO; HEART LEFT VENTRICLE EJECTION FRACTION; HEART SURGERY; HEART VALVE REPLACEMENT; HEMODYNAMICS; HUMAN; LOG RANK TEST; MAJOR CLINICAL STUDY; MALE; MORTALITY; PATIENT SATISFACTION; PREDICTOR VARIABLE; PRIORITY JOURNAL; PROPORTIONAL HAZARDS MODEL; STATISTICAL SIGNIFICANCE; SURGICAL MORTALITY; SURVIVAL; SURVIVAL TIME; TOP HAT PROSTHETIC HEART VALVE; TREATMENT OUTCOME; ADOLESCENT; AORTA VALVE STENOSIS; BIOPROSTHESIS; COHORT ANALYSIS; COMPARATIVE STUDY; DOPPLER ECHOCARDIOGRAPHY; ECHOGRAPHY; HEART VALVE PROSTHESIS; KAPLAN MEIER METHOD; METHODOLOGY; MIDDLE AGED; NONPARAMETRIC TEST; POSTOPERATIVE COMPLICATION; PROSTHESIS; PROSTHESIS FAILURE; RETROSPECTIVE STUDY; RISK ASSESSMENT; SURVIVAL RATE; TIME;

EID: 47049096373     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2008.01.085     Document Type: Article
Times cited : (13)

References (22)
  • 1
    • 0032466576 scopus 로고    scopus 로고
    • Valve related complications in elderly patients with biological and mechanical aortic valves
    • Milano A., Guglieimi C., De Carlo M., et al. Valve related complications in elderly patients with biological and mechanical aortic valves. Ann Thorac Surg 66 Suppl (1998) S82-S87
    • (1998) Ann Thorac Surg , vol.66 , Issue.SUPPL
    • Milano, A.1    Guglieimi, C.2    De Carlo, M.3
  • 2
    • 0010955435 scopus 로고    scopus 로고
    • Bioprosthetic versus mechanical prostheses for aortic valve replacement in the elderly
    • Davis E.A., Greene P.S., Cameron D.E., et al. Bioprosthetic versus mechanical prostheses for aortic valve replacement in the elderly. Circulation 94 Suppl (1996) II-121-II-125
    • (1996) Circulation , vol.94 , Issue.SUPPL , pp. 121-125
    • Davis, E.A.1    Greene, P.S.2    Cameron, D.E.3
  • 3
    • 0042859863 scopus 로고    scopus 로고
    • Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    • Blais C., Dumesnil J.G., Baillot R., Simard S., Doyle D., and Pibarot P.H. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108 (2003) 983-988
    • (2003) Circulation , vol.108 , pp. 983-988
    • Blais, C.1    Dumesnil, J.G.2    Baillot, R.3    Simard, S.4    Doyle, D.5    Pibarot, P.H.6
  • 4
    • 33644858444 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
    • Tasca G., Mhagna Z., Perotti S., et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis. Circulation 113 (2006) 570-576
    • (2006) Circulation , vol.113 , pp. 570-576
    • Tasca, G.1    Mhagna, Z.2    Perotti, S.3
  • 5
    • 0034619384 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch affects survival after aortic valve replacement
    • Rao V., Jamieson W.R., Ivanov J., et al. Prosthesis-patient mismatch affects survival after aortic valve replacement. Circulation 102 Suppl 3 (2000) 5-9
    • (2000) Circulation , vol.102 , Issue.SUPPL. 3 , pp. 5-9
    • Rao, V.1    Jamieson, W.R.2    Ivanov, J.3
  • 6
    • 0028989106 scopus 로고
    • The CarboMedics "Top Hat" supraannular prosthesis in the small aortic root
    • Rödler S., Moritz A., Wutte M., Hoda R., and Wolner E. The CarboMedics "Top Hat" supraannular prosthesis in the small aortic root. J Cardiac Surg 10 (1995) 198-204
    • (1995) J Cardiac Surg , vol.10 , pp. 198-204
    • Rödler, S.1    Moritz, A.2    Wutte, M.3    Hoda, R.4    Wolner, E.5
  • 7
    • 0342276117 scopus 로고    scopus 로고
    • Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis
    • Rödler S., Moritz A., Schreiner W., End A., Dubsky P., and Wolner E. Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis. Ann Thorac Surg 63 (1997) 1018-1025
    • (1997) Ann Thorac Surg , vol.63 , pp. 1018-1025
    • Rödler, S.1    Moritz, A.2    Schreiner, W.3    End, A.4    Dubsky, P.5    Wolner, E.6
  • 9
    • 0037998090 scopus 로고    scopus 로고
    • Logistic or additive EuroSCORE for high-risk patients?
    • Michel P., Roques F., and Nashef S.A. Logistic or additive EuroSCORE for high-risk patients?. Eur J Cardiothorac Surg 23 (2003) 684-687
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 684-687
    • Michel, P.1    Roques, F.2    Nashef, S.A.3
  • 10
    • 14244252089 scopus 로고    scopus 로고
    • A 10-year experience with the CarboMedics cardiac prosthesis
    • Tominaga R., Kurisu K., Ochiai Y., et al. A 10-year experience with the CarboMedics cardiac prosthesis. Ann Thorac Surg 79 (2005) 784-789
    • (2005) Ann Thorac Surg , vol.79 , pp. 784-789
    • Tominaga, R.1    Kurisu, K.2    Ochiai, Y.3
  • 11
    • 33846926368 scopus 로고    scopus 로고
    • Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve
    • Aagaard J., and Geha A.S. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve. J Heart Valve Dis 16 (2007) 84-90
    • (2007) J Heart Valve Dis , vol.16 , pp. 84-90
    • Aagaard, J.1    Geha, A.S.2
  • 13
    • 0026717861 scopus 로고
    • Hemodynamic evaluation by Doppler cardiography of small (less than or equal to 21 mm) prostheses and bioprostheses in the aortic valve position
    • Wiseth R., Levang O.W., Sande E., Tangen G., Skjaerpe T., and Hatle L. Hemodynamic evaluation by Doppler cardiography of small (less than or equal to 21 mm) prostheses and bioprostheses in the aortic valve position. Am J Cardiol 70 (1992) 240-246
    • (1992) Am J Cardiol , vol.70 , pp. 240-246
    • Wiseth, R.1    Levang, O.W.2    Sande, E.3    Tangen, G.4    Skjaerpe, T.5    Hatle, L.6
  • 14
    • 0041854625 scopus 로고    scopus 로고
    • Assessment of mechanical aortic valve prosthesis by means of Doppler echocardiography. What to measure and why?
    • Vannan M.A., and Sarkar K. Assessment of mechanical aortic valve prosthesis by means of Doppler echocardiography. What to measure and why?. J Thorac Cardiovasc Surg 126 (2003) 317-320
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 317-320
    • Vannan, M.A.1    Sarkar, K.2
  • 15
    • 33751441079 scopus 로고    scopus 로고
    • The influence of prosthesis size and design on exercise dynamics after aortic valve replacement
    • Ali N.F., Mahadevan V.S., Muir A., et al. The influence of prosthesis size and design on exercise dynamics after aortic valve replacement. J Heart Valve Dis 15 (2006) 755-762
    • (2006) J Heart Valve Dis , vol.15 , pp. 755-762
    • Ali, N.F.1    Mahadevan, V.S.2    Muir, A.3
  • 16
    • 22544479420 scopus 로고    scopus 로고
    • Validation and refinement of mortality risk models for heart valve surgery
    • Jin R., Grunkemeier G.L., and Starr A. Validation and refinement of mortality risk models for heart valve surgery. Ann Thorac Surg 80 (2005) 471-479
    • (2005) Ann Thorac Surg , vol.80 , pp. 471-479
    • Jin, R.1    Grunkemeier, G.L.2    Starr, A.3
  • 17
    • 0035115632 scopus 로고    scopus 로고
    • Aortic valve replacement in geriatric patients: determinants of in-hospital mortality
    • Bloomstein L.Z., Gielchinsky I., Bernestein A.D., et al. Aortic valve replacement in geriatric patients: determinants of in-hospital mortality. Ann Thorac Surg 71 (2001) 597-600
    • (2001) Ann Thorac Surg , vol.71 , pp. 597-600
    • Bloomstein, L.Z.1    Gielchinsky, I.2    Bernestein, A.D.3
  • 18
    • 33847323002 scopus 로고    scopus 로고
    • Effect of prior valve type on mortality in reoperative valve surgery
    • Tang G.H., Maganti M., David T., et al. Effect of prior valve type on mortality in reoperative valve surgery. Ann Thorac Surg 83 (2007) 938-945
    • (2007) Ann Thorac Surg , vol.83 , pp. 938-945
    • Tang, G.H.1    Maganti, M.2    David, T.3
  • 19
    • 0028831740 scopus 로고
    • Reoperation on prosthetic heart valves. Patient-specific estimates of in-hospital events
    • Piehler J.M., Blackstone E.H., Bailey K.R., et al. Reoperation on prosthetic heart valves. Patient-specific estimates of in-hospital events. J Thorac Cardiovasc Surg 109 (1995) 30-48
    • (1995) J Thorac Cardiovasc Surg , vol.109 , pp. 30-48
    • Piehler, J.M.1    Blackstone, E.H.2    Bailey, K.R.3
  • 20
  • 21
    • 4444324517 scopus 로고    scopus 로고
    • Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves
    • Bottio T., Caprilli L., Casarotto D., and Gerosa G. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves. J Thorac Cardiovasc Surg 128 (2004) 457-462
    • (2004) J Thorac Cardiovasc Surg , vol.128 , pp. 457-462
    • Bottio, T.1    Caprilli, L.2    Casarotto, D.3    Gerosa, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.