메뉴 건너뛰기




Volumn 126, Issue 2, 2003, Pages 317-320

Assessment of mechanical aortic valve prosthesis by means of Doppler echocardiography: What to measure and why?

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE; AORTA VALVE PROSTHESIS; BIOMECHANICS; DOPPLER ECHOCARDIOGRAPHY; EDITORIAL; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; PREDICTION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL;

EID: 0041854625     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-5223(03)00121-1     Document Type: Editorial
Times cited : (7)

References (7)
  • 2
    • 0024158242 scopus 로고
    • Overestimation by Doppler echocardiography of pressure gradients across Starr-Edwards prosthetic valves in the aortic position
    • Rothbart RM, Smucker ML, Gibson RS. Overestimation by Doppler echocardiography of pressure gradients across Starr-Edwards prosthetic valves in the aortic position. Am J Cardiol. 1988;61:475-6.
    • (1988) Am J Cardiol , vol.61 , pp. 475-476
    • Rothbart, R.M.1    Smucker, M.L.2    Gibson, R.S.3
  • 3
    • 0027207265 scopus 로고
    • Discrepancies between Doppler and catheter gradients across bileaflet aortic valve prostheses
    • Baumgartner H, Schima H, Kuhn P. Discrepancies between Doppler and catheter gradients across bileaflet aortic valve prostheses. Am J Cardiol. 1993;71:1241-3.
    • (1993) Am J Cardiol , vol.71 , pp. 1241-1243
    • Baumgartner, H.1    Schima, H.2    Kuhn, P.3
  • 4
    • 0025552864 scopus 로고
    • Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery
    • Baumgartner H, Khan S, DeRobertis M, Czer L, Maurer G. Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery. Circulation. 1990;82:1467-75.
    • (1990) Circulation , vol.82 , pp. 1467-1475
    • Baumgartner, H.1    Khan, S.2    DeRobertis, M.3    Czer, L.4    Maurer, G.5
  • 5
    • 0023256095 scopus 로고
    • Continuous-wave Doppler velocities and gradients across fixed tunnel obstructions: Studies in vitro and in vivo
    • Yoganathan AP, Valdes-Cruz LM, Schmidt-Dohna J, Jimoh A, Berry C, Tamura T, et al. Continuous-wave Doppler velocities and gradients across fixed tunnel obstructions: studies in vitro and in vivo. Circulation. 1987;76:657-66.
    • (1987) Circulation , vol.76 , pp. 657-666
    • Yoganathan, A.P.1    Valdes-Cruz, L.M.2    Schmidt-Dohna, J.3    Jimoh, A.4    Berry, C.5    Tamura, T.6
  • 6
    • 85047680457 scopus 로고
    • Comparision of Doppler ultrasound velocity measurements with pressure differences across bioprosthetic valves in a pulsatile flow model
    • Simpson IA, Fisher J, Reece IJ, Houston AB, Hutton I, Wheatley DJ. Comparision of Doppler ultrasound velocity measurements with pressure differences across bioprosthetic valves in a pulsatile flow model. Cardiovasc Res. 1986;20:317-21.
    • (1986) Cardiovasc Res , vol.20 , pp. 317-321
    • Simpson, I.A.1    Fisher, J.2    Reece, I.J.3    Houston, A.B.4    Hutton, I.5    Wheatley, D.J.6
  • 7
    • 0028853909 scopus 로고
    • Pressure recovery in bileaflet heart valve prostheses. Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position
    • Vandervoort PM, Greenberg NL, Powell KA, Cosgrove DM, Thomas JD. Pressure recovery in bileaflet heart valve prostheses. Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position. Circulation. 1995;92:3464-72.
    • (1995) Circulation , vol.92 , pp. 3464-3472
    • Vandervoort, P.M.1    Greenberg, N.L.2    Powell, K.A.3    Cosgrove, D.M.4    Thomas, J.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.